1 .. SPDX-License-Identifier: GPL-2.0-or-later
8 * Amphenol CC2D23, CC2D23S, CC2D25, CC2D25S, CC2D33, CC2D33S, CC2D35, CC2D35S
14 Datasheet: https://www.amphenol-sensors.com/en/telaire/humidity/527-humidity-sensors/3095-chipcap-2
18 - Javier Carrasco <javier.carrasco.cruz@gmail.com>
23 This driver implements support for the Amphenol ChipCap 2, a humidity and
24 temperature chip family. Temperature is measured in milli degrees celsius,
25 relative humidity is expressed as a per cent mille. The measurement ranges
28 - Relative humidity: 0 to 100000 pcm (14-bit resolution)
29 - Temperature: -40000 to +125000 m°C (14-bit resolution)
31 The device communicates with the I2C protocol and uses the I2C address 0x28
34 Depending on the hardware configuration, up to two humidity alarms to control
35 minimum and maximum values are provided. Their thresholds and hystersis can be
38 Thresholds and hysteris must be provided as a per cent mille. These values
39 might be truncated to match the 14-bit device resolution (6.1 pcm/LSB)
44 The driver does not support I2C address and command window length modification.
49 The following list includes the sysfs attributes that the driver always provides,
50 their permissions and a short description:
52 =============================== ======= ========================================
54 =============================== ======= ========================================
55 temp1_input: RO temperature input
56 humidity1_input: RO humidity input
57 =============================== ======= ========================================
59 The following list includes the sysfs attributes that the driver may provide
60 depending on the hardware configuration:
62 =============================== ======= ========================================
64 =============================== ======= ========================================
65 humidity1_min: RW humidity low limit. Measurements under
66 this limit trigger a humidity low alarm
67 humidity1_max: RW humidity high limit. Measurements above
68 this limit trigger a humidity high alarm
69 humidity1_min_hyst: RW humidity low hystersis
70 humidity1_max_hyst: RW humidity high hystersis
71 humidity1_min_alarm: RO humidity low alarm indicator
72 humidity1_max_alarm: RO humidity high alarm indicator
73 =============================== ======= ========================================