drm/tests: hdmi: Fix memory leaks in drm_display_mode_from_cea_vic()
[drm/drm-misc.git] / Documentation / hwmon / thmc50.rst
blob090f040294a34bf27a3d0cd4b3d676f6c3389c31
1 Kernel driver thmc50
2 =====================
4 Supported chips:
6   * Analog Devices ADM1022
8     Prefix: 'adm1022'
10     Addresses scanned: I2C 0x2c - 0x2e
12     Datasheet: http://www.analog.com/en/prod/0,2877,ADM1022,00.html
14   * Texas Instruments THMC50
16     Prefix: 'thmc50'
18     Addresses scanned: I2C 0x2c - 0x2e
20     Datasheet: https://www.ti.com/
23 Author: Krzysztof Helt <krzysztof.h1@wp.pl>
25 This driver was derived from the 2.4 kernel thmc50.c source file.
27 Credits:
29   thmc50.c (2.4 kernel):
31         - Frodo Looijaard <frodol@dds.nl>
32         - Philip Edelbrock <phil@netroedge.com>
34 Module Parameters
35 -----------------
37 * adm1022_temp3: short array
38     List of adapter,address pairs to force chips into ADM1022 mode with
39     second remote temperature. This does not work for original THMC50 chips.
41 Description
42 -----------
44 The THMC50 implements: an internal temperature sensor, support for an
45 external diode-type temperature sensor (compatible w/ the diode sensor inside
46 many processors), and a controllable fan/analog_out DAC. For the temperature
47 sensors, limits can be set through the appropriate Overtemperature Shutdown
48 register and Hysteresis register. Each value can be set and read to half-degree
49 accuracy.  An alarm is issued (usually to a connected LM78) when the
50 temperature gets higher then the Overtemperature Shutdown value; it stays on
51 until the temperature falls below the Hysteresis value. All temperatures are in
52 degrees Celsius, and are guaranteed within a range of -55 to +125 degrees.
54 The THMC50 only updates its values each 1.5 seconds; reading it more often
55 will do no harm, but will return 'old' values.
57 The THMC50 is usually used in combination with LM78-like chips, to measure
58 the temperature of the processor(s).
60 The ADM1022 works the same as THMC50 but it is faster (5 Hz instead of
61 1 Hz for THMC50). It can be also put in a new mode to handle additional
62 remote temperature sensor. The driver use the mode set by BIOS by default.
64 In case the BIOS is broken and the mode is set incorrectly, you can force
65 the mode with additional remote temperature with adm1022_temp3 parameter.
66 A typical symptom of wrong setting is a fan forced to full speed.
68 Driver Features
69 ---------------
71 The driver provides up to three temperatures:
73 temp1
74         - internal
75 temp2
76         - remote
77 temp3
78         - 2nd remote only for ADM1022
80 pwm1
81         - fan speed (0 = stop, 255 = full)
82 pwm1_mode
83         - always 0 (DC mode)
85 The value of 0 for pwm1 also forces FAN_OFF signal from the chip,
86 so it stops fans even if the value 0 into the ANALOG_OUT register does not.
88 The driver was tested on Compaq AP550 with two ADM1022 chips (one works
89 in the temp3 mode), five temperature readings and two fans.