powerpc/powernv: Report size of OPAL memcons log
[linux/fpc-iii.git] / Documentation / hwmon / w83792d
blobf2ffc402ea4519b6d9ba140ebfe72f88d1f67f4f
1 Kernel driver w83792d
2 =====================
4 Supported chips:
5   * Winbond W83792D
6     Prefix: 'w83792d'
7     Addresses scanned: I2C 0x2c - 0x2f
8     Datasheet: http://www.winbond.com.tw
10 Author: Shane Huang (Winbond)
11 Updated: Roger Lucas
14 Module Parameters
15 -----------------
17 * init int
18   (default 1)
19   Use 'init=0' to bypass initializing the chip.
20   Try this if your computer crashes when you load the module.
22 * force_subclients=bus,caddr,saddr,saddr
23   This is used to force the i2c addresses for subclients of
24   a certain chip. Example usage is `force_subclients=0,0x2f,0x4a,0x4b'
25   to force the subclients of chip 0x2f on bus 0 to i2c addresses
26   0x4a and 0x4b.
29 Description
30 -----------
32 This driver implements support for the Winbond W83792AD/D.
34 Detection of the chip can sometimes be foiled because it can be in an
35 internal state that allows no clean access (Bank with ID register is not
36 currently selected). If you know the address of the chip, use a 'force'
37 parameter; this will put it into a more well-behaved state first.
39 The driver implements three temperature sensors, seven fan rotation speed
40 sensors, nine voltage sensors, and two automatic fan regulation
41 strategies called: Smart Fan I (Thermal Cruise mode) and Smart Fan II.
43 The driver also implements up to seven fan control outputs: pwm1-7.  Pwm1-7
44 can be configured to PWM output or Analogue DC output via their associated
45 pwmX_mode. Outputs pwm4 through pwm7 may or may not be present depending on
46 how the W83792AD/D was configured by the BIOS.
48 Automatic fan control mode is possible only for fan1-fan3.
50 For all pwmX outputs, a value of 0 means minimum fan speed and a value of
51 255 means maximum fan speed.
53 Temperatures are measured in degrees Celsius and measurement resolution is 1
54 degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when
55 the temperature gets higher than the Overtemperature Shutdown value; it stays
56 on until the temperature falls below the Hysteresis value.
58 Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
59 triggered if the rotation speed has dropped below a programmable limit. Fan
60 readings can be divided by a programmable divider (1, 2, 4, 8, 16, 32, 64 or
61 128) to give the readings more range or accuracy.
63 Voltage sensors (also known as IN sensors) report their values in millivolts.
64 An alarm is triggered if the voltage has crossed a programmable minimum
65 or maximum limit.
67 Alarms are provided as output from "realtime status register". Following bits
68 are defined:
70 bit - alarm on:
71 0  - in0
72 1  - in1
73 2  - temp1
74 3  - temp2
75 4  - temp3
76 5  - fan1
77 6  - fan2
78 7  - fan3
79 8  - in2
80 9  - in3
81 10 - in4
82 11 - in5
83 12 - in6
84 13 - VID change
85 14 - chassis
86 15 - fan7
87 16 - tart1
88 17 - tart2
89 18 - tart3
90 19 - in7
91 20 - in8
92 21 - fan4
93 22 - fan5
94 23 - fan6
96 Tart will be asserted while target temperature cannot be achieved after 3 minutes
97 of full speed rotation of corresponding fan.
99 In addition to the alarms described above, there is a CHAS alarm on the chips
100 which triggers if your computer case is open (This one is latched, contrary
101 to realtime alarms).
103 The chips only update values each 3 seconds; reading them more often will
104 do no harm, but will return 'old' values.
107 W83792D PROBLEMS
108 ----------------
109 Known problems:
110         - This driver is only for Winbond W83792D C version device, there
111           are also some motherboards with B version W83792D device. The
112           calculation method to in6-in7(measured value, limits) is a little
113           different between C and B version. C or B version can be identified
114           by CR[0x49h].
115         - The function of vid and vrm has not been finished, because I'm NOT
116           very familiar with them. Adding support is welcome.
117         - The function of chassis open detection needs more tests.
118         - If you have ASUS server board and chip was not found: Then you will
119           need to upgrade to latest (or beta) BIOS. If it does not help please
120           contact us.
122 Fan control
123 -----------
125 Manual mode
126 -----------
128 Works as expected. You just need to specify desired PWM/DC value (fan speed)
129 in appropriate pwm# file.
131 Thermal cruise
132 --------------
134 In this mode, W83792D provides the Smart Fan system to automatically control
135 fan speed to keep the temperatures of CPU and the system within specific
136 range. At first a wanted temperature and interval must be set. This is done
137 via thermal_cruise# file. The tolerance# file serves to create T +- tolerance
138 interval. The fan speed will be lowered as long as the current temperature
139 remains below the thermal_cruise# +- tolerance# value. Once the temperature
140 exceeds the high limit (T+tolerance), the fan will be turned on with a
141 specific speed set by pwm# and automatically controlled its PWM duty cycle
142 with the temperature varying. Three conditions may occur:
144 (1) If the temperature still exceeds the high limit, PWM duty
145 cycle will increase slowly.
147 (2) If the temperature goes below the high limit, but still above the low
148 limit (T-tolerance), the fan speed will be fixed at the current speed because
149 the temperature is in the target range.
151 (3) If the temperature goes below the low limit, PWM duty cycle will decrease
152 slowly to 0 or a preset stop value until the temperature exceeds the low
153 limit. (The preset stop value handling is not yet implemented in driver)
155 Smart Fan II
156 ------------
158 W83792D also provides a special mode for fan. Four temperature points are
159 available. When related temperature sensors detects the temperature in preset
160 temperature region (sf2_point@_fan# +- tolerance#) it will cause fans to run
161 on programmed value from sf2_level@_fan#. You need to set four temperatures
162 for each fan.
165 /sys files
166 ----------
168 pwm[1-7] - this file stores PWM duty cycle or DC value (fan speed) in range:
169         0 (stop) to 255 (full)
170 pwm[1-3]_enable - this file controls mode of fan/temperature control:
171             * 0 Disabled
172             * 1 Manual mode
173             * 2 Smart Fan II
174             * 3 Thermal Cruise
175 pwm[1-7]_mode - Select PWM or DC mode
176             * 0 DC
177             * 1 PWM
178 thermal_cruise[1-3] - Selects the desired temperature for cruise (degC)
179 tolerance[1-3] - Value in degrees of Celsius (degC) for +- T
180 sf2_point[1-4]_fan[1-3] - four temperature points for each fan for Smart Fan II
181 sf2_level[1-3]_fan[1-3] - three PWM/DC levels for each fan for Smart Fan II