1 Kernel driver lm63
2 ==================
4 Supported chips:
5   * National Semiconductor LM63
6     Prefix: 'lm63'
7     Addresses scanned: I2C 0x4c
8     Datasheet: Publicly available at the National Semiconductor website
9                http://www.national.com/pf/LM/LM63.html
11 Author: Jean Delvare <khali@linux-fr.org>
13 Thanks go to Tyan and especially Alex Buckingham for setting up a remote
14 access to their S4882 test platform for this driver.
15   http://www.tyan.com/
17 Description
18 -----------
20 The LM63 is a digital temperature sensor with integrated fan monitoring
21 and control.
23 The LM63 is basically an LM86 with fan speed monitoring and control
24 capabilities added. It misses some of the LM86 features though:
25  - No low limit for local temperature.
26  - No critical limit for local temperature.
27  - Critical limit for remote temperature can be changed only once. We
28    will consider that the critical limit is read-only.
30 The datasheet isn't very clear about what the tachometer reading is.
32 An explanation from National Semiconductor: The two lower bits of the read
33 value have to be masked out. The value is still 16 bit in width.
35 All temperature values are given in degrees Celsius. Resolution is 1.0
36 degree for the local temperature, 0.125 degree for the remote temperature.
38 The fan speed is measured using a tachometer. Contrary to most chips which
39 store the value in an 8-bit register and have a selectable clock divider
40 to make sure that the result will fit in the register, the LM63 uses 16-bit
41 value for measuring the speed of the fan. It can measure fan speeds down to
42 83 RPM, at least in theory.
44 Note that the pin used for fan monitoring is shared with an alert out
45 function. Depending on how the board designer wanted to use the chip, fan
46 speed monitoring will or will not be possible. The proper chip configuration
47 is left to the BIOS, and the driver will blindly trust it.
49 A PWM output can be used to control the speed of the fan. The LM63 has two
50 PWM modes: manual and automatic. Automatic mode is not fully implemented yet
51 (you cannot define your custom PWM/temperature curve), and mode change isn't
52 supported either.
54 The lm63 driver will not update its values more frequently than every
55 second; reading them more often will do no harm, but will return 'old'
56 values.