qlcnic: Fix mailbox completion handling during spurious interrupt
[linux/fpc-iii.git] / Documentation / hwmon / da9052
blob5bc51346b6897aead6100151d4faaab80722c694
1 Supported chips:
2   * Dialog Semiconductors DA9052-BC and DA9053-AA/Bx PMICs
3     Prefix: 'da9052'
4     Datasheet: Datasheet is not publicly available.
6 Authors: David Dajun Chen <dchen@diasemi.com>
8 Description
9 -----------
11 The DA9052/53 provides an Analogue to Digital Converter (ADC) with 10 bits
12 resolution and track and hold circuitry combined with an analogue input
13 multiplexer. The analogue input multiplexer will allow conversion of up to 10
14 different inputs. The track and hold circuit ensures stable input voltages at
15 the input of the ADC during the conversion.
17 The ADC is used to measure the following inputs:
18 Channel 0: VDDOUT - measurement of the system voltage
19 Channel 1: ICH - internal battery charger current measurement
20 Channel 2: TBAT - output from the battery NTC
21 Channel 3: VBAT - measurement of the battery voltage
22 Channel 4: ADC_IN4 - high impedance input (0 - 2.5V)
23 Channel 5: ADC_IN5 - high impedance input (0 - 2.5V)
24 Channel 6: ADC_IN6 - high impedance input (0 - 2.5V)
25 Channel 7: XY - TSI interface to measure the X and Y voltage of the touch
26            screen resistive potentiometers
27 Channel 8: Internal Tjunc. - sense (internal temp. sensor)
28 Channel 9: VBBAT - measurement of the backup battery voltage
30 By using sysfs attributes we can measure the system voltage VDDOUT, the battery
31 charging current ICH, battery temperature TBAT, battery junction temperature
32 TJUNC, battery voltage VBAT and the back up battery voltage VBBAT.
34 Voltage Monitoring
35 ------------------
37 Voltages are sampled by a 10 bit ADC.
39 The battery voltage is calculated as:
40         Milli volt = ((ADC value * 1000) / 512) + 2500
42 The backup battery voltage is calculated as:
43         Milli volt = (ADC value * 2500) / 512;
45 The voltages on ADC channels 4, 5 and 6 are calculated as:
46         Milli volt = (ADC value * 2500) / 1023
48 Temperature Monitoring
49 ----------------------
51 Temperatures are sampled by a 10 bit ADC.  Junction and battery temperatures
52 are monitored by the ADC channels.
54 The junction temperature is calculated:
55         Degrees celsius = 1.708 * (TJUNC_RES - T_OFFSET) - 108.8
56 The junction temperature attribute is supported by the driver.
58 The battery temperature is calculated:
59         Degree Celsius = 1 / (t1 + 1/298)- 273
60 where t1 = (1/B)* ln(( ADCval * 2.5)/(R25*ITBAT*255))
61 Default values of R25, B, ITBAT are 10e3, 3380 and 50e-6 respectively.