qlcnic: Fix mailbox completion handling during spurious interrupt
[linux/fpc-iii.git] / Documentation / hwmon / max1668
blob0616ed9758dfdd96058018191447973a54bb3a5c
1 Kernel driver max1668
2 =====================
4 Supported chips:
5   * Maxim MAX1668, MAX1805 and MAX1989
6     Prefix: 'max1668'
7     Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b, 0x4c, 0x4d, 0x4e
8     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX1668-MAX1989.pdf
10 Author:
11     David George <david.george@ska.ac.za>
13 Description
14 -----------
16 This driver implements support for the Maxim MAX1668, MAX1805 and MAX1989
17 chips.
19 The three devices are very similar, but the MAX1805 has a reduced feature
20 set; only two remote temperature inputs vs the four avaible on the other
21 two ICs.
23 The driver is able to distinguish between the devices and creates sysfs
24 entries as follows:
26 MAX1805, MAX1668 and MAX1989:
28 temp1_input     ro local (ambient) temperature
29 temp1_max       rw local temperature maximum threshold for alarm
30 temp1_max_alarm ro local temperature maximum threshold alarm
31 temp1_min       rw local temperature minimum threshold for alarm
32 temp1_min_alarm ro local temperature minimum threshold alarm
33 temp2_input     ro remote temperature 1
34 temp2_max       rw remote temperature 1 maximum threshold for alarm
35 temp2_max_alarm ro remote temperature 1 maximum threshold alarm
36 temp2_min       rw remote temperature 1 minimum threshold for alarm
37 temp2_min_alarm ro remote temperature 1 minimum threshold alarm
38 temp3_input     ro remote temperature 2
39 temp3_max       rw remote temperature 2 maximum threshold for alarm
40 temp3_max_alarm ro remote temperature 2 maximum threshold alarm
41 temp3_min       rw remote temperature 2 minimum threshold for alarm
42 temp3_min_alarm ro remote temperature 2 minimum threshold alarm
44 MAX1668 and MAX1989 only:
45 temp4_input     ro remote temperature 3
46 temp4_max       rw remote temperature 3 maximum threshold for alarm
47 temp4_max_alarm ro remote temperature 3 maximum threshold alarm
48 temp4_min       rw remote temperature 3 minimum threshold for alarm
49 temp4_min_alarm ro remote temperature 3 minimum threshold alarm
50 temp5_input     ro remote temperature 4
51 temp5_max       rw remote temperature 4 maximum threshold for alarm
52 temp5_max_alarm ro remote temperature 4 maximum threshold alarm
53 temp5_min       rw remote temperature 4 minimum threshold for alarm
54 temp5_min_alarm ro remote temperature 4 minimum threshold alarm
56 Module Parameters
57 -----------------
59 * read_only: int
60   Set to non-zero if you wish to prevent write access to alarm thresholds.