rxrpc: Show some more information through /proc files
[linux/fpc-iii.git] / Documentation / hwmon / smsc47b397
blob3a43b694892490b564350cff1169e26e6487d048
1 Kernel driver smsc47b397
2 ========================
4 Supported chips:
5   * SMSC LPC47B397-NC
6   * SMSC SCH5307-NS
7   * SMSC SCH5317
8     Prefix: 'smsc47b397'
9     Addresses scanned: none, address read from Super I/O config space
10     Datasheet: In this file
12 Authors: Mark M. Hoffman <mhoffman@lightlink.com>
13          Utilitek Systems, Inc.
15 November 23, 2004
17 The following specification describes the SMSC LPC47B397-NC[1] sensor chip
18 (for which there is no public datasheet available). This document was
19 provided by Craig Kelly (In-Store Broadcast Network) and edited/corrected
20 by Mark M. Hoffman <mhoffman@lightlink.com>.
22 [1] And SMSC SCH5307-NS and SCH5317, which have different device IDs but are
23 otherwise compatible.
25 * * * * *
27 Methods for detecting the HP SIO and reading the thermal data on a dc7100.
29 The thermal information on the dc7100 is contained in the SIO Hardware Monitor
30 (HWM). The information is accessed through an index/data pair. The index/data
31 pair is located at the HWM Base Address + 0 and the HWM Base Address + 1. The
32 HWM Base address can be obtained from Logical Device 8, registers 0x60 (MSB)
33 and 0x61 (LSB). Currently we are using 0x480 for the HWM Base Address and
34 0x480 and 0x481 for the index/data pair.
36 Reading temperature information.
37 The temperature information is located in the following registers:
38 Temp1           0x25    (Currently, this reflects the CPU temp on all systems).
39 Temp2           0x26
40 Temp3           0x27
41 Temp4           0x80
43 Programming Example
44 The following is an example of how to read the HWM temperature registers:
45 MOV     DX,480H
46 MOV     AX,25H
47 OUT     DX,AL
48 MOV     DX,481H
49 IN      AL,DX
51 AL contains the data in hex, the temperature in Celsius is the decimal
52 equivalent.
54 Ex: If AL contains 0x2A, the temperature is 42 degrees C.
56 Reading tach information.
57 The fan speed information is located in the following registers:
58                 LSB     MSB
59 Tach1           0x28    0x29    (Currently, this reflects the CPU
60                                 fan speed on all systems).
61 Tach2           0x2A    0x2B
62 Tach3           0x2C    0x2D
63 Tach4           0x2E    0x2F
65 Important!!!
66 Reading the tach LSB locks the tach MSB.
67 The LSB Must be read first.
69 How to convert the tach reading to RPM.
70 The tach reading (TCount) is given by: (Tach MSB * 256) + (Tach LSB)
71 The SIO counts the number of 90kHz (11.111us) pulses per revolution.
72 RPM = 60/(TCount * 11.111us)
74 Example:
75 Reg 0x28 = 0x9B
76 Reg 0x29 = 0x08
78 TCount = 0x89B = 2203
80 RPM = 60 / (2203 * 11.11111 E-6) = 2451 RPM
82 Obtaining the SIO version.
84 CONFIGURATION SEQUENCE
85 To program the configuration registers, the following sequence must be followed:
86 1. Enter Configuration Mode
87 2. Configure the Configuration Registers
88 3. Exit Configuration Mode.
90 Enter Configuration Mode
91 To place the chip into the Configuration State The config key (0x55) is written
92 to the CONFIG PORT (0x2E).
94 Configuration Mode
95 In configuration mode, the INDEX PORT is located at the CONFIG PORT address and
96 the DATA PORT is at INDEX PORT address + 1.
98 The desired configuration registers are accessed in two steps:
99 a.      Write the index of the Logical Device Number Configuration Register
100         (i.e., 0x07) to the INDEX PORT and then write the number of the
101         desired logical device to the DATA PORT.
103 b.      Write the address of the desired configuration register within the
104         logical device to the INDEX PORT and then write or read the config-
105         uration register through the DATA PORT.
107 Note: If accessing the Global Configuration Registers, step (a) is not required.
109 Exit Configuration Mode
110 To exit the Configuration State the write 0xAA to the CONFIG PORT (0x2E).
111 The chip returns to the RUN State.  (This is important).
113 Programming Example
114 The following is an example of how to read the SIO Device ID located at 0x20
116 ; ENTER CONFIGURATION MODE
117 MOV     DX,02EH
118 MOV     AX,055H
119 OUT     DX,AL
120 ; GLOBAL CONFIGURATION  REGISTER
121 MOV     DX,02EH
122 MOV     AL,20H
123 OUT     DX,AL
124 ; READ THE DATA
125 MOV     DX,02FH
126 IN      AL,DX
127 ; EXIT CONFIGURATION MODE
128 MOV     DX,02EH
129 MOV     AX,0AAH
130 OUT     DX,AL
132 The registers of interest for identifying the SIO on the dc7100 are Device ID
133 (0x20) and Device Rev  (0x21).
135 The Device ID will read 0x6F (0x81 for SCH5307-NS, and 0x85 for SCH5317)
136 The Device Rev currently reads 0x01
138 Obtaining the HWM Base Address.
139 The following is an example of how to read the HWM Base Address located in
140 Logical Device 8.
142 ; ENTER CONFIGURATION MODE
143 MOV     DX,02EH
144 MOV     AX,055H
145 OUT     DX,AL
146 ; CONFIGURE REGISTER CRE0,
147 ; LOGICAL DEVICE 8
148 MOV     DX,02EH
149 MOV     AL,07H
150 OUT     DX,AL ;Point to LD# Config Reg
151 MOV     DX,02FH
152 MOV     AL, 08H
153 OUT     DX,AL;Point to Logical Device 8
155 MOV     DX,02EH
156 MOV     AL,60H
157 OUT     DX,AL   ; Point to HWM Base Addr MSB
158 MOV     DX,02FH
159 IN      AL,DX   ; Get MSB of HWM Base Addr
160 ; EXIT CONFIGURATION MODE
161 MOV     DX,02EH
162 MOV     AX,0AAH
163 OUT     DX,AL