ext4: fix some nonstandard indentation in extents.c
[linux/fpc-iii.git] / Documentation / hwmon / max6639.rst
blob3da54225f83cd07bbec0b7f86f3594308668ff48
1 Kernel driver max6639
2 =====================
4 Supported chips:
6   * Maxim MAX6639
8     Prefix: 'max6639'
10     Addresses scanned: I2C 0x2c, 0x2e, 0x2f
12     Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf
14 Authors:
15     - He Changqing <hechangqing@semptian.com>
16     - Roland Stigge <stigge@antcom.de>
18 Description
19 -----------
21 This driver implements support for the Maxim MAX6639. This chip is a 2-channel
22 temperature monitor with dual PWM fan speed controller. It can monitor its own
23 temperature and one external diode-connected transistor or two external
24 diode-connected transistors.
26 The following device attributes are implemented via sysfs:
28 ====================== ==== ===================================================
29 Attribute              R/W  Contents
30 ====================== ==== ===================================================
31 temp1_input            R    Temperature channel 1 input (0..150 C)
32 temp2_input            R    Temperature channel 2 input (0..150 C)
33 temp1_fault            R    Temperature channel 1 diode fault
34 temp2_fault            R    Temperature channel 2 diode fault
35 temp1_max              RW   Set THERM temperature for input 1
36                             (in C, see datasheet)
37 temp2_max              RW   Set THERM temperature for input 2
38 temp1_crit             RW   Set ALERT temperature for input 1
39 temp2_crit             RW   Set ALERT temperature for input 2
40 temp1_emergency        RW   Set OT temperature for input 1
41                             (in C, see datasheet)
42 temp2_emergency        RW   Set OT temperature for input 2
43 pwm1                   RW   Fan 1 target duty cycle (0..255)
44 pwm2                   RW   Fan 2 target duty cycle (0..255)
45 fan1_input             R    TACH1 fan tachometer input (in RPM)
46 fan2_input             R    TACH2 fan tachometer input (in RPM)
47 fan1_fault             R    Fan 1 fault
48 fan2_fault             R    Fan 2 fault
49 temp1_max_alarm        R    Alarm on THERM temperature on channel 1
50 temp2_max_alarm        R    Alarm on THERM temperature on channel 2
51 temp1_crit_alarm       R    Alarm on ALERT temperature on channel 1
52 temp2_crit_alarm       R    Alarm on ALERT temperature on channel 2
53 temp1_emergency_alarm  R    Alarm on OT temperature on channel 1
54 temp2_emergency_alarm  R    Alarm on OT temperature on channel 2
55 ====================== ==== ===================================================