ALSA: hda - Add support of new codec ALC233
[linux/fpc-iii.git] / Documentation / networking / ixgbe.txt
blobaf77ed3c4172088bf57b11d57183f003031b7cab
1 Linux Base Driver for 10 Gigabit PCI Express Intel(R) Network Connection
2 ========================================================================
4 Intel Gigabit Linux driver.
5 Copyright(c) 1999 - 2010 Intel Corporation.
7 Contents
8 ========
10 - Identifying Your Adapter
11 - Additional Configurations
12 - Performance Tuning
13 - Known Issues
14 - Support
16 Identifying Your Adapter
17 ========================
19 The driver in this release is compatible with 82598 and 82599-based Intel
20 Network Connections.
22 For more information on how to identify your adapter, go to the Adapter &
23 Driver ID Guide at:
25     http://support.intel.com/support/network/sb/CS-012904.htm
27 SFP+ Devices with Pluggable Optics
28 ----------------------------------
30 82599-BASED ADAPTERS
32 NOTES: If your 82599-based Intel(R) Network Adapter came with Intel optics, or
33 is an Intel(R) Ethernet Server Adapter X520-2, then it only supports Intel
34 optics and/or the direct attach cables listed below.
36 When 82599-based SFP+ devices are connected back to back, they should be set to
37 the same Speed setting via ethtool. Results may vary if you mix speed settings.
38 82598-based adapters support all passive direct attach cables that comply
39 with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach
40 cables are not supported.
42 Supplier    Type                                             Part Numbers
44 SR Modules
45 Intel       DUAL RATE 1G/10G SFP+ SR (bailed)                FTLX8571D3BCV-IT
46 Intel       DUAL RATE 1G/10G SFP+ SR (bailed)                AFBR-703SDDZ-IN1
47 Intel       DUAL RATE 1G/10G SFP+ SR (bailed)                AFBR-703SDZ-IN2
48 LR Modules
49 Intel       DUAL RATE 1G/10G SFP+ LR (bailed)                FTLX1471D3BCV-IT
50 Intel       DUAL RATE 1G/10G SFP+ LR (bailed)                AFCT-701SDDZ-IN1
51 Intel       DUAL RATE 1G/10G SFP+ LR (bailed)                AFCT-701SDZ-IN2
53 The following is a list of 3rd party SFP+ modules and direct attach cables that
54 have received some testing. Not all modules are applicable to all devices.
56 Supplier   Type                                              Part Numbers
58 Finisar    SFP+ SR bailed, 10g single rate                   FTLX8571D3BCL
59 Avago      SFP+ SR bailed, 10g single rate                   AFBR-700SDZ
60 Finisar    SFP+ LR bailed, 10g single rate                   FTLX1471D3BCL
62 Finisar    DUAL RATE 1G/10G SFP+ SR (No Bail)                FTLX8571D3QCV-IT
63 Avago      DUAL RATE 1G/10G SFP+ SR (No Bail)                AFBR-703SDZ-IN1
64 Finisar    DUAL RATE 1G/10G SFP+ LR (No Bail)                FTLX1471D3QCV-IT
65 Avago      DUAL RATE 1G/10G SFP+ LR (No Bail)                AFCT-701SDZ-IN1
66 Finistar   1000BASE-T SFP                                    FCLF8522P2BTL
67 Avago      1000BASE-T SFP                                    ABCU-5710RZ
69 82599-based adapters support all passive and active limiting direct attach
70 cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications.
72 Laser turns off for SFP+ when ifconfig down
73 -------------------------------------------
74 "ifconfig down" turns off the laser for 82599-based SFP+ fiber adapters.
75 "ifconfig up" turns on the later.
78 82598-BASED ADAPTERS
80 NOTES for 82598-Based Adapters:
81 - Intel(R) Network Adapters that support removable optical modules only support
82   their original module type (i.e., the Intel(R) 10 Gigabit SR Dual Port
83   Express Module only supports SR optical modules). If you plug in a different
84   type of module, the driver will not load.
85 - Hot Swapping/hot plugging optical modules is not supported.
86 - Only single speed, 10 gigabit modules are supported.
87 - LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module
88   types are not supported. Please see your system documentation for details.
90 The following is a list of 3rd party SFP+ modules and direct attach cables that
91 have received some testing. Not all modules are applicable to all devices.
93 Supplier   Type                                              Part Numbers
95 Finisar    SFP+ SR bailed, 10g single rate                   FTLX8571D3BCL
96 Avago      SFP+ SR bailed, 10g single rate                   AFBR-700SDZ
97 Finisar    SFP+ LR bailed, 10g single rate                   FTLX1471D3BCL
99 82598-based adapters support all passive direct attach cables that comply
100 with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach
101 cables are not supported.
104 Flow Control
105 ------------
106 Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable
107 receiving and transmitting pause frames for ixgbe. When TX is enabled, PAUSE
108 frames are generated when the receive packet buffer crosses a predefined
109 threshold.  When rx is enabled, the transmit unit will halt for the time delay
110 specified when a PAUSE frame is received.
112 Flow Control is enabled by default. If you want to disable a flow control
113 capable link partner, use ethtool:
115      ethtool -A eth? autoneg off RX off TX off
117 NOTE: For 82598 backplane cards entering 1 gig mode, flow control default
118 behavior is changed to off.  Flow control in 1 gig mode on these devices can
119 lead to Tx hangs.
121 Additional Configurations
122 =========================
124   Jumbo Frames
125   ------------
126   The driver supports Jumbo Frames for all adapters. Jumbo Frames support is
127   enabled by changing the MTU to a value larger than the default of 1500.
128   The maximum value for the MTU is 16110.  Use the ifconfig command to
129   increase the MTU size.  For example:
131         ifconfig ethx mtu 9000 up
133   The maximum MTU setting for Jumbo Frames is 16110.  This value coincides
134   with the maximum Jumbo Frames size of 16128.
136   Generic Receive Offload, aka GRO
137   --------------------------------
138   The driver supports the in-kernel software implementation of GRO.  GRO has
139   shown that by coalescing Rx traffic into larger chunks of data, CPU
140   utilization can be significantly reduced when under large Rx load.  GRO is an
141   evolution of the previously-used LRO interface.  GRO is able to coalesce
142   other protocols besides TCP.  It's also safe to use with configurations that
143   are problematic for LRO, namely bridging and iSCSI.
145   Data Center Bridging, aka DCB
146   -----------------------------
147   DCB is a configuration Quality of Service implementation in hardware.
148   It uses the VLAN priority tag (802.1p) to filter traffic.  That means
149   that there are 8 different priorities that traffic can be filtered into.
150   It also enables priority flow control which can limit or eliminate the
151   number of dropped packets during network stress.  Bandwidth can be
152   allocated to each of these priorities, which is enforced at the hardware
153   level.
155   To enable DCB support in ixgbe, you must enable the DCB netlink layer to
156   allow the userspace tools (see below) to communicate with the driver.
157   This can be found in the kernel configuration here:
159         -> Networking support
160           -> Networking options
161             -> Data Center Bridging support
163   Once this is selected, DCB support must be selected for ixgbe.  This can
164   be found here:
166         -> Device Drivers
167           -> Network device support (NETDEVICES [=y])
168             -> Ethernet (10000 Mbit) (NETDEV_10000 [=y])
169               -> Intel(R) 10GbE PCI Express adapters support
170                 -> Data Center Bridging (DCB) Support
172   After these options are selected, you must rebuild your kernel and your
173   modules.
175   In order to use DCB, userspace tools must be downloaded and installed.
176   The dcbd tools can be found at:
178         http://e1000.sf.net
180   Ethtool
181   -------
182   The driver utilizes the ethtool interface for driver configuration and
183   diagnostics, as well as displaying statistical information. The latest
184   ethtool version is required for this functionality.
186   The latest release of ethtool can be found from
187   http://ftp.kernel.org/pub/software/network/ethtool/
189   FCoE
190   ----
191   This release of the ixgbe driver contains new code to enable users to use
192   Fiber Channel over Ethernet (FCoE) and Data Center Bridging (DCB)
193   functionality that is supported by the 82598-based hardware.  This code has
194   no default effect on the regular driver operation, and configuring DCB and
195   FCoE is outside the scope of this driver README. Refer to
196   http://www.open-fcoe.org/ for FCoE project information and contact
197   e1000-eedc@lists.sourceforge.net for DCB information.
199   MAC and VLAN anti-spoofing feature
200   ----------------------------------
201   When a malicious driver attempts to send a spoofed packet, it is dropped by
202   the hardware and not transmitted.  An interrupt is sent to the PF driver
203   notifying it of the spoof attempt.
205   When a spoofed packet is detected the PF driver will send the following
206   message to the system log (displayed by  the "dmesg" command):
208   Spoof event(s) detected on VF (n)
210   Where n=the VF that attempted to do the spoofing.
213 Performance Tuning
214 ==================
216 An excellent article on performance tuning can be found at:
218 http://www.redhat.com/promo/summit/2008/downloads/pdf/Thursday/Mark_Wagner.pdf
221 Known Issues
222 ============
224   Enabling SR-IOV in a 32-bit Microsoft* Windows* Server 2008 Guest OS using
225   Intel (R) 82576-based GbE or Intel (R) 82599-based 10GbE controller under KVM
226   -----------------------------------------------------------------------------
227   KVM Hypervisor/VMM supports direct assignment of a PCIe device to a VM.  This
228   includes traditional PCIe devices, as well as SR-IOV-capable devices using
229   Intel 82576-based and 82599-based controllers.
231   While direct assignment of a PCIe device or an SR-IOV Virtual Function (VF)
232   to a Linux-based VM running 2.6.32 or later kernel works fine, there is a
233   known issue with Microsoft Windows Server 2008 VM that results in a "yellow
234   bang" error. This problem is within the KVM VMM itself, not the Intel driver,
235   or the SR-IOV logic of the VMM, but rather that KVM emulates an older CPU
236   model for the guests, and this older CPU model does not support MSI-X
237   interrupts, which is a requirement for Intel SR-IOV.
239   If you wish to use the Intel 82576 or 82599-based controllers in SR-IOV mode
240   with KVM and a Microsoft Windows Server 2008 guest try the following
241   workaround. The workaround is to tell KVM to emulate a different model of CPU
242   when using qemu to create the KVM guest:
244        "-cpu qemu64,model=13"
247 Support
248 =======
250 For general information, go to the Intel support website at:
252     http://support.intel.com
254 or the Intel Wired Networking project hosted by Sourceforge at:
256     http://e1000.sourceforge.net
258 If an issue is identified with the released source code on the supported
259 kernel with a supported adapter, email the specific information related
260 to the issue to e1000-devel@lists.sf.net