ALSA: hda/realtek - Optimize alc888_coef_init()
[linux/fpc-iii.git] / Documentation / arm / cluster-pm-race-avoidance.txt
blob750b6fc24af92438e6f9a112b312819e5ecf7b94
1 Cluster-wide Power-up/power-down race avoidance algorithm
2 =========================================================
4 This file documents the algorithm which is used to coordinate CPU and
5 cluster setup and teardown operations and to manage hardware coherency
6 controls safely.
8 The section "Rationale" explains what the algorithm is for and why it is
9 needed.  "Basic model" explains general concepts using a simplified view
10 of the system.  The other sections explain the actual details of the
11 algorithm in use.
14 Rationale
15 ---------
17 In a system containing multiple CPUs, it is desirable to have the
18 ability to turn off individual CPUs when the system is idle, reducing
19 power consumption and thermal dissipation.
21 In a system containing multiple clusters of CPUs, it is also desirable
22 to have the ability to turn off entire clusters.
24 Turning entire clusters off and on is a risky business, because it
25 involves performing potentially destructive operations affecting a group
26 of independently running CPUs, while the OS continues to run.  This
27 means that we need some coordination in order to ensure that critical
28 cluster-level operations are only performed when it is truly safe to do
29 so.
31 Simple locking may not be sufficient to solve this problem, because
32 mechanisms like Linux spinlocks may rely on coherency mechanisms which
33 are not immediately enabled when a cluster powers up.  Since enabling or
34 disabling those mechanisms may itself be a non-atomic operation (such as
35 writing some hardware registers and invalidating large caches), other
36 methods of coordination are required in order to guarantee safe
37 power-down and power-up at the cluster level.
39 The mechanism presented in this document describes a coherent memory
40 based protocol for performing the needed coordination.  It aims to be as
41 lightweight as possible, while providing the required safety properties.
44 Basic model
45 -----------
47 Each cluster and CPU is assigned a state, as follows:
49         DOWN
50         COMING_UP
51         UP
52         GOING_DOWN
54             +---------> UP ----------+
55             |                        v
57         COMING_UP                GOING_DOWN
59             ^                        |
60             +--------- DOWN <--------+
63 DOWN:   The CPU or cluster is not coherent, and is either powered off or
64         suspended, or is ready to be powered off or suspended.
66 COMING_UP: The CPU or cluster has committed to moving to the UP state.
67         It may be part way through the process of initialisation and
68         enabling coherency.
70 UP:     The CPU or cluster is active and coherent at the hardware
71         level.  A CPU in this state is not necessarily being used
72         actively by the kernel.
74 GOING_DOWN: The CPU or cluster has committed to moving to the DOWN
75         state.  It may be part way through the process of teardown and
76         coherency exit.
79 Each CPU has one of these states assigned to it at any point in time.
80 The CPU states are described in the "CPU state" section, below.
82 Each cluster is also assigned a state, but it is necessary to split the
83 state value into two parts (the "cluster" state and "inbound" state) and
84 to introduce additional states in order to avoid races between different
85 CPUs in the cluster simultaneously modifying the state.  The cluster-
86 level states are described in the "Cluster state" section.
88 To help distinguish the CPU states from cluster states in this
89 discussion, the state names are given a CPU_ prefix for the CPU states,
90 and a CLUSTER_ or INBOUND_ prefix for the cluster states.
93 CPU state
94 ---------
96 In this algorithm, each individual core in a multi-core processor is
97 referred to as a "CPU".  CPUs are assumed to be single-threaded:
98 therefore, a CPU can only be doing one thing at a single point in time.
100 This means that CPUs fit the basic model closely.
102 The algorithm defines the following states for each CPU in the system:
104         CPU_DOWN
105         CPU_COMING_UP
106         CPU_UP
107         CPU_GOING_DOWN
109          cluster setup and
110         CPU setup complete          policy decision
111               +-----------> CPU_UP ------------+
112               |                                v
114         CPU_COMING_UP                   CPU_GOING_DOWN
116               ^                                |
117               +----------- CPU_DOWN <----------+
118          policy decision           CPU teardown complete
119         or hardware event
122 The definitions of the four states correspond closely to the states of
123 the basic model.
125 Transitions between states occur as follows.
127 A trigger event (spontaneous) means that the CPU can transition to the
128 next state as a result of making local progress only, with no
129 requirement for any external event to happen.
132 CPU_DOWN:
134         A CPU reaches the CPU_DOWN state when it is ready for
135         power-down.  On reaching this state, the CPU will typically
136         power itself down or suspend itself, via a WFI instruction or a
137         firmware call.
139         Next state:     CPU_COMING_UP
140         Conditions:     none
142         Trigger events:
144                 a) an explicit hardware power-up operation, resulting
145                    from a policy decision on another CPU;
147                 b) a hardware event, such as an interrupt.
150 CPU_COMING_UP:
152         A CPU cannot start participating in hardware coherency until the
153         cluster is set up and coherent.  If the cluster is not ready,
154         then the CPU will wait in the CPU_COMING_UP state until the
155         cluster has been set up.
157         Next state:     CPU_UP
158         Conditions:     The CPU's parent cluster must be in CLUSTER_UP.
159         Trigger events: Transition of the parent cluster to CLUSTER_UP.
161         Refer to the "Cluster state" section for a description of the
162         CLUSTER_UP state.
165 CPU_UP:
166         When a CPU reaches the CPU_UP state, it is safe for the CPU to
167         start participating in local coherency.
169         This is done by jumping to the kernel's CPU resume code.
171         Note that the definition of this state is slightly different
172         from the basic model definition: CPU_UP does not mean that the
173         CPU is coherent yet, but it does mean that it is safe to resume
174         the kernel.  The kernel handles the rest of the resume
175         procedure, so the remaining steps are not visible as part of the
176         race avoidance algorithm.
178         The CPU remains in this state until an explicit policy decision
179         is made to shut down or suspend the CPU.
181         Next state:     CPU_GOING_DOWN
182         Conditions:     none
183         Trigger events: explicit policy decision
186 CPU_GOING_DOWN:
188         While in this state, the CPU exits coherency, including any
189         operations required to achieve this (such as cleaning data
190         caches).
192         Next state:     CPU_DOWN
193         Conditions:     local CPU teardown complete
194         Trigger events: (spontaneous)
197 Cluster state
198 -------------
200 A cluster is a group of connected CPUs with some common resources.
201 Because a cluster contains multiple CPUs, it can be doing multiple
202 things at the same time.  This has some implications.  In particular, a
203 CPU can start up while another CPU is tearing the cluster down.
205 In this discussion, the "outbound side" is the view of the cluster state
206 as seen by a CPU tearing the cluster down.  The "inbound side" is the
207 view of the cluster state as seen by a CPU setting the CPU up.
209 In order to enable safe coordination in such situations, it is important
210 that a CPU which is setting up the cluster can advertise its state
211 independently of the CPU which is tearing down the cluster.  For this
212 reason, the cluster state is split into two parts:
214         "cluster" state: The global state of the cluster; or the state
215                 on the outbound side:
217                 CLUSTER_DOWN
218                 CLUSTER_UP
219                 CLUSTER_GOING_DOWN
221         "inbound" state: The state of the cluster on the inbound side.
223                 INBOUND_NOT_COMING_UP
224                 INBOUND_COMING_UP
227         The different pairings of these states results in six possible
228         states for the cluster as a whole:
230                                     CLUSTER_UP
231                   +==========> INBOUND_NOT_COMING_UP -------------+
232                   #                                               |
233                                                                   |
234              CLUSTER_UP     <----+                                |
235           INBOUND_COMING_UP      |                                v
237                   ^             CLUSTER_GOING_DOWN       CLUSTER_GOING_DOWN
238                   #              INBOUND_COMING_UP <=== INBOUND_NOT_COMING_UP
240             CLUSTER_DOWN         |                                |
241           INBOUND_COMING_UP <----+                                |
242                                                                   |
243                   ^                                               |
244                   +===========     CLUSTER_DOWN      <------------+
245                                INBOUND_NOT_COMING_UP
247         Transitions -----> can only be made by the outbound CPU, and
248         only involve changes to the "cluster" state.
250         Transitions ===##> can only be made by the inbound CPU, and only
251         involve changes to the "inbound" state, except where there is no
252         further transition possible on the outbound side (i.e., the
253         outbound CPU has put the cluster into the CLUSTER_DOWN state).
255         The race avoidance algorithm does not provide a way to determine
256         which exact CPUs within the cluster play these roles.  This must
257         be decided in advance by some other means.  Refer to the section
258         "Last man and first man selection" for more explanation.
261         CLUSTER_DOWN/INBOUND_NOT_COMING_UP is the only state where the
262         cluster can actually be powered down.
264         The parallelism of the inbound and outbound CPUs is observed by
265         the existence of two different paths from CLUSTER_GOING_DOWN/
266         INBOUND_NOT_COMING_UP (corresponding to GOING_DOWN in the basic
267         model) to CLUSTER_DOWN/INBOUND_COMING_UP (corresponding to
268         COMING_UP in the basic model).  The second path avoids cluster
269         teardown completely.
271         CLUSTER_UP/INBOUND_COMING_UP is equivalent to UP in the basic
272         model.  The final transition to CLUSTER_UP/INBOUND_NOT_COMING_UP
273         is trivial and merely resets the state machine ready for the
274         next cycle.
276         Details of the allowable transitions follow.
278         The next state in each case is notated
280                 <cluster state>/<inbound state> (<transitioner>)
282         where the <transitioner> is the side on which the transition
283         can occur; either the inbound or the outbound side.
286 CLUSTER_DOWN/INBOUND_NOT_COMING_UP:
288         Next state:     CLUSTER_DOWN/INBOUND_COMING_UP (inbound)
289         Conditions:     none
290         Trigger events:
292                 a) an explicit hardware power-up operation, resulting
293                    from a policy decision on another CPU;
295                 b) a hardware event, such as an interrupt.
298 CLUSTER_DOWN/INBOUND_COMING_UP:
300         In this state, an inbound CPU sets up the cluster, including
301         enabling of hardware coherency at the cluster level and any
302         other operations (such as cache invalidation) which are required
303         in order to achieve this.
305         The purpose of this state is to do sufficient cluster-level
306         setup to enable other CPUs in the cluster to enter coherency
307         safely.
309         Next state:     CLUSTER_UP/INBOUND_COMING_UP (inbound)
310         Conditions:     cluster-level setup and hardware coherency complete
311         Trigger events: (spontaneous)
314 CLUSTER_UP/INBOUND_COMING_UP:
316         Cluster-level setup is complete and hardware coherency is
317         enabled for the cluster.  Other CPUs in the cluster can safely
318         enter coherency.
320         This is a transient state, leading immediately to
321         CLUSTER_UP/INBOUND_NOT_COMING_UP.  All other CPUs on the cluster
322         should consider treat these two states as equivalent.
324         Next state:     CLUSTER_UP/INBOUND_NOT_COMING_UP (inbound)
325         Conditions:     none
326         Trigger events: (spontaneous)
329 CLUSTER_UP/INBOUND_NOT_COMING_UP:
331         Cluster-level setup is complete and hardware coherency is
332         enabled for the cluster.  Other CPUs in the cluster can safely
333         enter coherency.
335         The cluster will remain in this state until a policy decision is
336         made to power the cluster down.
338         Next state:     CLUSTER_GOING_DOWN/INBOUND_NOT_COMING_UP (outbound)
339         Conditions:     none
340         Trigger events: policy decision to power down the cluster
343 CLUSTER_GOING_DOWN/INBOUND_NOT_COMING_UP:
345         An outbound CPU is tearing the cluster down.  The selected CPU
346         must wait in this state until all CPUs in the cluster are in the
347         CPU_DOWN state.
349         When all CPUs are in the CPU_DOWN state, the cluster can be torn
350         down, for example by cleaning data caches and exiting
351         cluster-level coherency.
353         To avoid wasteful unnecessary teardown operations, the outbound
354         should check the inbound cluster state for asynchronous
355         transitions to INBOUND_COMING_UP.  Alternatively, individual
356         CPUs can be checked for entry into CPU_COMING_UP or CPU_UP.
359         Next states:
361         CLUSTER_DOWN/INBOUND_NOT_COMING_UP (outbound)
362                 Conditions:     cluster torn down and ready to power off
363                 Trigger events: (spontaneous)
365         CLUSTER_GOING_DOWN/INBOUND_COMING_UP (inbound)
366                 Conditions:     none
367                 Trigger events:
369                         a) an explicit hardware power-up operation,
370                            resulting from a policy decision on another
371                            CPU;
373                         b) a hardware event, such as an interrupt.
376 CLUSTER_GOING_DOWN/INBOUND_COMING_UP:
378         The cluster is (or was) being torn down, but another CPU has
379         come online in the meantime and is trying to set up the cluster
380         again.
382         If the outbound CPU observes this state, it has two choices:
384                 a) back out of teardown, restoring the cluster to the
385                    CLUSTER_UP state;
387                 b) finish tearing the cluster down and put the cluster
388                    in the CLUSTER_DOWN state; the inbound CPU will
389                    set up the cluster again from there.
391         Choice (a) permits the removal of some latency by avoiding
392         unnecessary teardown and setup operations in situations where
393         the cluster is not really going to be powered down.
396         Next states:
398         CLUSTER_UP/INBOUND_COMING_UP (outbound)
399                 Conditions:     cluster-level setup and hardware
400                                 coherency complete
401                 Trigger events: (spontaneous)
403         CLUSTER_DOWN/INBOUND_COMING_UP (outbound)
404                 Conditions:     cluster torn down and ready to power off
405                 Trigger events: (spontaneous)
408 Last man and First man selection
409 --------------------------------
411 The CPU which performs cluster tear-down operations on the outbound side
412 is commonly referred to as the "last man".
414 The CPU which performs cluster setup on the inbound side is commonly
415 referred to as the "first man".
417 The race avoidance algorithm documented above does not provide a
418 mechanism to choose which CPUs should play these roles.
421 Last man:
423 When shutting down the cluster, all the CPUs involved are initially
424 executing Linux and hence coherent.  Therefore, ordinary spinlocks can
425 be used to select a last man safely, before the CPUs become
426 non-coherent.
429 First man:
431 Because CPUs may power up asynchronously in response to external wake-up
432 events, a dynamic mechanism is needed to make sure that only one CPU
433 attempts to play the first man role and do the cluster-level
434 initialisation: any other CPUs must wait for this to complete before
435 proceeding.
437 Cluster-level initialisation may involve actions such as configuring
438 coherency controls in the bus fabric.
440 The current implementation in mcpm_head.S uses a separate mutual exclusion
441 mechanism to do this arbitration.  This mechanism is documented in
442 detail in vlocks.txt.
445 Features and Limitations
446 ------------------------
448 Implementation:
450         The current ARM-based implementation is split between
451         arch/arm/common/mcpm_head.S (low-level inbound CPU operations) and
452         arch/arm/common/mcpm_entry.c (everything else):
454         __mcpm_cpu_going_down() signals the transition of a CPU to the
455                 CPU_GOING_DOWN state.
457         __mcpm_cpu_down() signals the transition of a CPU to the CPU_DOWN
458                 state.
460         A CPU transitions to CPU_COMING_UP and then to CPU_UP via the
461                 low-level power-up code in mcpm_head.S.  This could
462                 involve CPU-specific setup code, but in the current
463                 implementation it does not.
465         __mcpm_outbound_enter_critical() and __mcpm_outbound_leave_critical()
466                 handle transitions from CLUSTER_UP to CLUSTER_GOING_DOWN
467                 and from there to CLUSTER_DOWN or back to CLUSTER_UP (in
468                 the case of an aborted cluster power-down).
470                 These functions are more complex than the __mcpm_cpu_*()
471                 functions due to the extra inter-CPU coordination which
472                 is needed for safe transitions at the cluster level.
474         A cluster transitions from CLUSTER_DOWN back to CLUSTER_UP via
475                 the low-level power-up code in mcpm_head.S.  This
476                 typically involves platform-specific setup code,
477                 provided by the platform-specific power_up_setup
478                 function registered via mcpm_sync_init.
480 Deep topologies:
482         As currently described and implemented, the algorithm does not
483         support CPU topologies involving more than two levels (i.e.,
484         clusters of clusters are not supported).  The algorithm could be
485         extended by replicating the cluster-level states for the
486         additional topological levels, and modifying the transition
487         rules for the intermediate (non-outermost) cluster levels.
490 Colophon
491 --------
493 Originally created and documented by Dave Martin for Linaro Limited, in
494 collaboration with Nicolas Pitre and Achin Gupta.
496 Copyright (C) 2012-2013  Linaro Limited
497 Distributed under the terms of Version 2 of the GNU General Public
498 License, as defined in linux/COPYING.