can: hi311x: Use level-triggered interrupt
commitf164d0204b1156a7e0d8d1622c1a8d25752befec
authorLukas Wunner <lukas@wunner.de>
Sat, 27 Oct 2018 08:36:54 +0000 (27 10:36 +0200)
committerMarc Kleine-Budde <mkl@pengutronix.de>
Fri, 9 Nov 2018 16:20:08 +0000 (9 17:20 +0100)
tree7516ad963c1b3329f5a34205aed56a91e2dd1b1e
parent868b7c0f43e61f227bf3d7f7d6134bb3c67bb0e8
can: hi311x: Use level-triggered interrupt

If the hi3110 shares the SPI bus with another traffic-intensive device
and packets are received in high volume (by a separate machine sending
with "cangen -g 0 -i -x"), reception stops after a few minutes and the
counter in /proc/interrupts stops incrementing.  Bus state is "active".
Bringing the interface down and back up reconvenes the reception.  The
issue is not observed when the hi3110 is the sole device on the SPI bus.

Using a level-triggered interrupt makes the issue go away and lets the
hi3110 successfully receive 2 GByte over the course of 5 days while a
ks8851 Ethernet chip on the same SPI bus handles 6 GByte of traffic.

Unfortunately the hi3110 datasheet is mum on the trigger type.  The pin
description on page 3 only specifies the polarity (active high):
http://www.holtic.com/documents/371-hi-3110_v-rev-kpdf.do

Cc: Mathias Duckeck <m.duckeck@kunbus.de>
Cc: Akshay Bhat <akshay.bhat@timesys.com>
Cc: Casey Fitzpatrick <casey.fitzpatrick@timesys.com>
Signed-off-by: Lukas Wunner <lukas@wunner.de>
Cc: linux-stable <stable@vger.kernel.org>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Documentation/devicetree/bindings/net/can/holt_hi311x.txt
drivers/net/can/spi/hi311x.c