3 --------------------------------------
4 EnSight User Defined Reader Capability ===> (API 2.0)
5 --------------------------------------
6 A user defined reader capability is included in EnSight which can allow
7 otherwise unsupported structured or unstructured data to be read. The user
8 defined reader capability utilizes dynamic shared libraries composed of
9 routines defined in this document but produced by you, the user, (or some
10 third party). This capability is currently available for dec, ibm, hp, sgi,
11 sun, linux, alpha linux, and NT servers.
13 Two versions of this API are available starting with EnSight Version 7.2. The
14 1.0 API (which was designed to be friendly to those producing it, but requires
15 more manipulation internally by EnSight) may be a little easier to
16 produce, but requires more memory and processing time. The 2.0 API is
17 considerably more efficient, and was designed more with that in mind. It
18 requires that all data be provided on a part basis.
20 If you already have a working 1.0 API reader and are happy with it - there is
21 probably no reason to modify it to the 2.0 API unless:
22 - you deal with large models and the memory use and load times are a
24 - you need tensor variable support or
25 - you need complex variable support or
26 - you need multiple timeset capability or
27 _ you want to provide your own "border" elements (as opposed to EnSight's
30 If you are producing a new reader, you should consider which will work best
34 API 1.0 (defined in README_USERD_1.0 document)
36 The original user defined reader API (used with EnSight Versions 6 through
37 7.1) will continue to be supported. (Note that there was a change in the way
38 that the libraries were made at version 7.1 of EnSight, but underlying code
39 was kept the same.) Thus, any readers that work with EnSight 7.1, should still
40 function with EnSight 7.2.
43 API 2.0 (defined in this README_USERD_2.0 document)
45 This new API has been defined to be more efficient and includes access to new
46 capabilities of EnSight 7.2. It lends itself closely to the EnSight "gold"
49 Some of its advantages are::
51 * Most intermediate temporary arrays have been eliminated, such that the user
52 defined routines write directly into internal part structures. This is a
53 considerable improvement in memory use, and improves speed as well since
54 far less memory need be allocated, initialized, etc.
56 * Parts are self contained. Coordinates, connectivity and all variables are
57 provided on a part basis. This eliminates the need for several global to
58 local coordinate mapping operations and the need for node id connectivity
59 hashing. This can greatly improve the speed at which models are loaded.
61 * Model extents can be provided directly, such that EnSight need not read
62 all the coordinate data at load time.
64 * Tensor variables are supported
66 * Complex variables are supported
68 * A routine is provided as EnSight exits, so cleanup operations such as
69 removing temporary files can be easily accomplished.
71 * Geometry and variables can be provided on different time lines (timesets).
73 * If your data format already provides boundary shell information, you can
74 use it instead of the "border" representation that EnSight would compute.
76 Further discussion on the philosophical differences between the two API's and
77 an efficiency comparison example can be found in the README_1.0_to_2.0 file.
78 This file also contains guidance on necessary changes to modify an existing
79 1.0 API to the new 2.0 API.
82 ****************************************************************************
83 Note: A default dummy_gold reader and an Ensight Gold example of this new 2.0
84 user defined reader API has been included with your EnSight release.
85 Also, the SILO reader included in the release utilizes the 2.0 API.
87 And while not identical, the API 1.0 readers might be useful to
88 examine as examples. Many of the routines are the same or similar.
89 ****************************************************************************
92 The process for producing a user defined reader is:
93 ---------------------------------------------------
94 1. Write code for all pertinent routines in the library (Unless someone else
95 has done this for you).
97 This is of course where the work is done by the user. The word
98 "pertinent" is used because depending on the nature of the data, some
99 of the routines in the library may be dummy routines.
101 The source code for a dummy_gold library and for various other
102 working or sample libraries is copied from the installation CD during
103 installation. These will be located in directories under:
105 $CEI_HOME/ensight76/user_defined_src/readers
109 Basic dummy_gold routines provide skeleton for a new reader
110 $CEI_HOME/ensight76/user_defined_src/readers/dummy_gold
112 Sample library which reads unstructured binary EnSight Gold data
113 $CEI_HOME/ensight76/user_defined_src/readers/ensight_gold
115 You may find it useful to place your library source in this area as
116 well, but are not limited to this location.
118 * ===> The descriptions of each library routine and the order that the
119 routines are called, which is provided in this file, along with
120 the example libraries, should make it possible for you to produce
121 code for your own data reader.
124 2. Produce the dynamic shared library.
126 This is a compiling and loading process which varies according to
127 the type of machine you are on. In the user-defined-reader source
128 tree we have tried to isolate the machine dependent parts of the
129 build process using a set of files in the 'config' directory. In this
130 directory there is a configuration file for each platform on which
131 EnSight is supported. Before you can compile the installed readers
132 you should run the script called 'init' in the config directory.
140 If you are compiling for Windows NT, there are two options. If you
141 have the Cygwin GNU utilities installed, you can use GNU make as for
142 Unix. Otherwise, there is a script called makeall.cmd which will
143 build all of the readers using nmake. The Makefiles in each reader
144 directory will work using either make or nmake.
146 i.e. (WIN32 Cygwin) (using nmake)
148 sh init win32 cp win32 config
153 If you have platform-specific portions of code in your reader, the
154 build system defines a set of flags which can be used within
155 #ifdef ... #endif regions in your source, as shown in the table
158 Because the readers are now dynamically opened by EnSight, you may
159 have to include dependent libraries on your link-line to avoid having
160 unresolved symbols. If you are having problems with a reader, start
161 ensight as "ensight7 -readerdbg" and you will get feedback on any
162 problems encountered in loading a reader. If there are unresolved
163 symbols, you need to find the library which contains the missing
164 symbols and link it into your reader by adding it to the example
167 If you choose to use a different build environment for your reader,
168 you should take care to use compatible compilation flags to ensure
169 compatibilty with the EnSight executables, most notably on the SGI
170 and HP-UX 11.0 platforms, which should use the following flags:
173 sgi_6.2_n64: -mips4 -64
175 sgi_6.5_n64: -mips4 -64
179 ______________________________________________________________________
180 | MACHINE | OS flag | SHARED LIBRARY NAME PRODUCED |
181 | TYPE |------------------------------------------------------------|
182 | | LD COMMAND USED IN MAKEFILE |
183 ======================================================================
184 ______________________________________________________________________
185 | sgi | -DSGI | libuserd-X.so |
186 | |------------------------------------------------------------|
187 | | ld -shared -all -o libuserd-X.so libuserd-X.o |
188 ----------------------------------------------------------------------
189 ______________________________________________________________________
190 | hp | -DHP | libuserd-X.sl |
191 | |------------------------------------------------------------|
192 | | ld -b -o libuserd-X.sl libuserd-X.o |
193 ----------------------------------------------------------------------
194 ______________________________________________________________________
195 | sun | -DSUN | libuserd-X.so |
196 | |------------------------------------------------------------|
197 | | ld -G -o libuserd-X.so libuserd-X.o |
198 ----------------------------------------------------------------------
199 ______________________________________________________________________
200 | dec | -DDEC | libuserd-X.so |
201 | |------------------------------------------------------------|
202 | | ld -shared -all -o libuserd-X.so libuserd-X.o -lc |
203 ----------------------------------------------------------------------
204 ______________________________________________________________________
205 | linux | -DLINUX | libuserd-X.so |
206 | |------------------------------------------------------------|
207 | | ld -shared -o libuserd-X.so libuserd-X.o -lc |
208 ----------------------------------------------------------------------
209 ______________________________________________________________________
210 | alpha | -DALINUX | libuserd-X.so |
211 | linux |------------------------------------------------------------|
212 | | ld -shared -o libuserd-X.so libuserd-X.o -lc |
213 ----------------------------------------------------------------------
214 ______________________________________________________________________
215 | ibm | -DIBM | libuserd-X.so |
216 | |------------------------------------------------------------|
217 | | ld -G -o libuserd-X.so libuserd-X.o -bnoentry -bexpall -lc |
218 ----------------------------------------------------------------------
220 Once you have created your library, you should place it in a directory
221 of your choice or in the standard reader location:
223 $CEI_HOME/ensight76/machines/$CEI_ARCH/lib_readers
225 For example, if you created a reader for "mydata", you should create
226 the reader libuserd-mydata.so and place the file in your own reader
227 directory (see section 3 below) or in the standard location:
229 $CEI_HOME/ensight76/machines/$CEI_ARCH/lib_readers/libuserd-mydata.so
232 3. By default EnSight will load all readers found in the directory:
234 $CEI_HOME/ensight76/machines/$CEI_ARCH/lib_readers
236 Files with names "libuserd-X.so" (where X is a name unique to the reader)
237 are assumed to be user-defined readers.
239 There are two methods which can be used to supplement the default
242 (1) A feature which is useful for site-level or user-level configuration
243 is the optional environment variable $ENSIGHT7_READER. This
244 variable directs EnSight to load all readers in the specified reader
245 directory (you should probably specify a full path) before loading
246 the built-in readers. If the same reader exists in both directories
247 (as determined by the name returned by USERD_get_name_of_reader(),
248 NOT by the filename), the locally configured reader will take
251 (2) A useful feature for end-users is the use of the libuserd-devel
252 reader. EnSight will search for a reader named libuserd-devel.so
253 (.sl for HP or .dll for NT). This reader can exist anywhere in the
254 library path (see below) of the user. This is useful for an
255 individual actively developing a reader because the existence of a
256 libuserd-devel library will take precedence over any other library
257 which returns the same name from USERD_get_name_of_reader().
259 As an example, a site may install commonly used readers in a common
260 location, and users can set the ENSIGHT7_READER variable to access them:
262 setenv ENSIGHT7_READER /usr/local/lib/e7readers
264 A user working on a new reader may compile the reader and place it in
265 a directory specified by the library path:
267 cp libuserd-myreader.so ~/lib/libuserd-devel.so
268 setenv <librarypath> ~/lib:$<librarypath>
270 The user is responsible for correctly configuring the library path
271 variable in order to make use of the libuserd-devel feature. The
272 library environment variables used are:
274 Machine type Environment variable to set
275 ------------ ---------------------------
279 linux LD_LIBRARY_PATH
280 alpha linux LD_LIBRARY_PATH
284 As always, EnSight support is available if you need it.
288 -------------------------------
289 Quick Index of Library Routines
290 -------------------------------
292 Generally Needed for UNSTRUCTURED data
293 --------------------------------------
294 USERD_get_part_coords part's node coordinates
295 USERD_get_part_node_ids part's node ids
296 USERD_get_part_elements_by_type part's element connectivites
297 USERD_get_part_element_ids_by_type part's element ids
300 Generally Needed for BLOCK data
301 --------------------------------------
302 USERD_get_block_coords_by_component block coordinates
303 USERD_get_block_iblanking block iblanking values
306 Generally needed for either or both kinds of data
307 -------------------------------------------------
308 USERD_get_name_of_reader name of reader for GUI
309 USERD_get_reader_version provide reader version number
310 USERD_get_reader_descrip provide GUI more description(optional)
312 USERD_set_filenames filenames entered in GUI
313 USERD_set_server_number server which of how many
315 USERD_get_number_of_timesets number of timesets
316 USERD_get_timeset_description description of timeset
317 USERD_get_geom_timeset_number timeset # to use for geom
319 USERD_get_num_of_time_steps number of time steps
320 USERD_get_sol_times solution time values
321 USERD_set_time_set_and_step current timeset and time step
324 USERD_get_changing_geometry_status changing geometry?
325 USERD_get_node_label_status node labels?
326 USERD_get_element_label_status element labels?
327 USERD_get_model_extents provide model bounding extents
328 USERD_get_number_of_files_in_dataset number of files in model
329 USERD_get_dataset_query_file_info info about each model file
330 USERD_get_descrip_lines file associated description lines
331 USERD_get_number_of_model_parts number of model parts
332 USERD_get_part_build_info part/block type/descrip etc.
333 USERD_get_maxsize_info part/block allocation maximums
335 USERD_get_border_availability part border provided?
336 USERD_get_border_elements_by_type part border conn and parent info
338 USERD_get_number_of_variables number of variables
339 USERD_get_gold_variable_info variable type/descrip etc.
340 USERD_get_var_by_component part or block variable values
341 USERD_get_constant_val constant variable's value
342 USERD_get_var_value_at_specific node's or element's variable
344 USERD_stop_part_building cleanup after part build routine
346 USERD_bkup archive routine
348 USERD_exit_routine cleanup upon exit routine
351 -------------------------
352 Order Routines are called
353 -------------------------
355 The various main operations are given basically in the order they will
356 be performed. Within each operation, the order the routines will be
359 1. Setting name in the gui, and specifying one or two input fields
361 USERD_get_name_of_reader
362 USERD_get_reader_descrip (optional)
364 2. Getting the reader version (also distinguishes between API's)
366 USERD_get_reader_version
368 3. Setting filenames and getting timeset and time info
370 USERD_set_server_number
372 USERD_get_number_of_timesets
373 USERD_get_geom_timeset_number
376 USERD_get_timeset_description
377 USERD_get_num_of_time_steps
380 USERD_set_time_set_and_step
382 4. Gathering info for part builder
384 USERD_set_time_set_and_step
385 USERD_get_changing_geometry_status
386 USERD_get_node_label_status
387 USERD_get_element_label_status
388 USERD_get_number_of_files_in_dataset
389 USERD_get_dataset_query_file_info
390 USERD_get_descrip_lines (for geometry)
391 USERD_get_number_of_model_parts
392 USERD_get_gold_part_build_info
393 USERD_get_maxsize_info
394 USERD_get_model_extents OR (for model extents)
395 USERD_get_part_coords AND/OR
396 USERD_get_block_coords_by_component
398 5. Gathering Variable info
400 USERD_get_number_of_variables
401 USERD_get_gold_variable_info
403 6. Part building (per part created)
405 USERD_set_time_set_and_step
406 USERD_get_part_element_ids_by_type
407 USERD_get_part_elements_by_type
408 USERD_get_part_coords
409 USERD_get_part_node_ids
410 USERD_get_block_iblanking
411 USERD_get_block_coords_by_component
413 USERD_get_border_availability (If border representation
414 USERD_get_border_elements_by_type is selected)
416 USERD_stop_part_building (only once when part builder
423 USERD_set_time_set_and_step
424 USERD_get_constant_val
426 scalars/vectors/tensors:
427 ------------------------
428 USERD_get_descrip_lines
429 USERD_set_time_set_and_step
430 USERD_get_var_by_component
434 changing coords only (per part):
436 USERD_set_time_set_and_step
437 USERD_get_descrip_lines
438 USERD_get_part_coords
439 USERD_get_block_coords_by_component
441 changing connectivity (per part):
442 ---------------------
443 USERD_set_time_set_and_step
444 USERD_get_descrip_lines
445 USERD_get_number_of_model_parts
446 USERD_get_gold_part_build_info
447 USERD_get_model_extents OR
448 USERD_get_part_coords AND/OR
449 USERD_get_block_coords_by_component
450 USERD_get_part_element_ids_by_type
451 USERD_get_part_elements_by_type
452 USERD_get_part_coords
453 USERD_get_part_node_ids
454 USERD_get_block_iblanking
455 USERD_get_block_coords_by_component
457 USERD_get_border_availability (If border representation
458 USERD_get_border_elements_by_type is selected)
461 9. Node or Element queries over time
463 USERD_get_var_value_at_specific
466 -----------------------
467 Detailed Specifications
468 -----------------------
472 The following header file is required in any file containing these library
475 #include "global_extern.h"
480 Unless explicitly stated otherwise, all arrays are zero based - in true C
486 You will generally need to have a few global variables which are shared by
487 the various library routines. The detailed specifications below have assumed
488 the following are available. (Their names describe their purpose, and they
489 will be used in helping describe the details of the routines below).
491 static int Numparts_available = 0;
492 static int Num_unstructured_parts = 0;
493 static int Num_structured_blocks = 0;
495 /* Note: Numparts_available = Num_unstructured_parts + Num_structured_blocks */
497 static int Num_timesets = 1;
498 static int Current_timeset = 1;
499 static int Geom_timeset_number = 1;
501 static int Num_time_steps[Z_MAXSETS] = 1;
502 static int Current_time_step = 0;
503 static int Num_variables = 0;
504 static int Num_dataset_files = 0;
506 static int Server_Number = 1; Which server of
507 static int Tot_Servers = 1; the total number of servers
511 _________________________________________
512 -----------------------------------------
513 Library Routines (in alphabetical order):
514 _________________________________________
515 -----------------------------------------
517 --------------------------------------------------------------------
522 This routine is called during the EnSight archive process. You can
523 use it to save or restore info relating to your user defined reader.
527 int USERD_bkup(FILE *archive_file,
533 Z_ERR if not successful
537 (IN) archive_file = The archive file pointer
539 (IN) backup_type = Z_SAVE_ARCHIVE for saving archive
540 Z_REST_ARCHIVE for restoring archive
544 * Since EnSight's archive file is saved in binary form, you should
545 also do any writing to it or reading from it in binary.
547 * You should archive any variables, which will be needed for
548 future operations, that will not be read or computed again
549 before they will be needed. These are typically global
552 * Make sure that the number of bytes that you write on a save and
553 the number of bytes that you read on a restore are identical!!
555 * If any of the variables you save are allocated arrays, you must
556 do the allocations before restoring into them.
558 --------------------------------------------------------------------
563 This routine is called as EnSight is exiting. It can be used to clean
564 up anything needed - such as removing temporary files, etc. - or can simply
569 void USERD_exit_routine( void )
575 --------------------------------------------------------------------
576 USERD_get_block_coords_by_component
580 Get the coordinates of a given structured block, a component at a time.
584 int USERD_get_block_coords_by_component(int block_number,
591 Z_ERR if not successful
595 (IN) block_number = The block part number
596 (1-based index of part table, namely:
598 1 ... Numparts_available.
600 It is NOT the part_id that
601 is loaded in USERD_get_gold_part_build_info)
603 (IN) which_component = Z_COMPX if x component wanted
604 = Z_COMPY if y component wanted
605 = Z_COMPZ if z component wanted
607 (OUT) coord_array = 1D array containing x,y, or z
608 coordinate component of each node
610 (Array will have been allocated
611 i*j*k for the block long)
615 * Not called unless Num_structured_blocks is > 0
617 * Will be based on Current_time_step
621 --------------------------------------------------------------------
622 USERD_get_block_iblanking
626 Get the iblanking value at each node of a block (if the block is
631 int USERD_get_block_iblanking(int block_number,
637 Z_ERR if not successful
641 (IN) block_number = The block part number
642 (1-based index of part table, namely:
644 1 ... Numparts_available.
646 It is NOT the part_id that
647 is loaded in USERD_get_gold_part_build_info)
649 (OUT) iblank_array = 1D array containing iblank value
652 (Array will have been allocated
653 i*j*k for the block long)
655 possible values are: Z_EXT = exterior
658 Z_INTBND = internal boundary
659 Z_SYM = symmetry plane
663 * Not called unless Num_structured_blocks is > 0 and you have
666 * Will be based on Current_time_step
670 --------------------------------------------------------------------
671 USERD_get_border_availability
675 Finds out if border elements are provided by the reader for the
676 desired part, or will need to be computed internally by EnSight.
680 int USERD_get_border_availability(int part_number,
681 int number_of_elements[Z_MAXTYPE])
685 Z_OK if border elements will be provided by the reader.
686 (number_of_elements array will be loaded and
687 USERD_get_border_elements_by_type will be called)
689 Z_ERR if border elements are not available - thus EnSight must compute.
690 (USERD_get_border_elements_by_type will not be called)
695 (IN) part_number = The part number
696 (1-based index of part table, namely:
698 1 ... Numparts_available.
700 It is NOT the part_id that
701 is loaded in USERD_get_gold_part_build_info)
703 (OUT) number_of_elements = 2D array containing number of
704 each type of border element in
710 Z_BAR02 = 2-noded bar
711 Z_BAR03 = 3-noded bar
712 Z_TRI03 = 3-noded triangle
713 Z_TRI06 = 6-noded triangle
714 Z_QUA04 = 4-noded quadrilateral
715 Z_QUA08 = 8-noded quadrilateral
719 * Only called if border representation is used.
721 * Will be based on Current_time_step
725 --------------------------------------------------------------------
726 USERD_get_border_elements_by_type
730 Provides border element connectivity and parent information.
734 int USERD_get_border_elements_by_type(int part_number,
737 short *parent_element_type,
738 int *parent_element_num)
743 Z_ERR if not successful
747 (IN) part_number = The part number
748 (1-based index of part table, namely:
750 1 ... Numparts_available.
752 It is NOT the part_id that
753 is loaded in USERD_get_gold_part_build_info)
755 (IN) element_type = One of the following (See global_extern.h)
756 Z_POINT node point element
759 Z_TRI03 3 node triangle
760 Z_TRI06 6 node triangle
764 (OUT) conn_array = 2D array containing connectivity
765 of each border element of the type.
767 (Array will have been allocated
768 num_of_elements of the type by
769 connectivity length of the type)
771 ex) If number_of_elements[Z_TRI03] = 25
772 number_of_elements[Z_QUA04] = 100
773 number_of_elements[Z_QUA08] = 30
775 USERD_get_border_availability
777 Then the allocated dimensions available
778 for this routine will be:
779 conn_array[25][3] when called with Z_TRI03
781 conn_array[100][4] when called with Z_QUA04
783 conn_array[30][8] when called with Z_QUA08
785 (OUT) parent_element_type = 1D array containing element type of the
786 parent element (the one that the border
787 element is a face/edge of).
789 (Array will have been allocated
790 num_of_elements of the type long)
792 (OUT) parent_element_num = 1D array containing element number of the
793 parent element (the one that the border
794 element is a face/edge of).
796 (Array will have been allocated
797 num_of_elements of the type long)
802 * Not called unless USERD_get_border_availability returned Z_OK
804 * Will be based on Current_time_step
808 --------------------------------------------------------------------
809 USERD_get_changing_geometry_status
813 Gets the changing geometry status for the model
817 int USERD_get_changing_geometry_status( void )
821 Z_STATIC if geometry does not change
822 Z_CHANGE_COORDS if changing coordinates only
823 Z_CHANGE_CONN if changing connectivity
831 * EnSight does not support changing number of parts. But the
832 coords and/or the connectivity of the parts can change. Note that
833 a part is allowed to be empty (number of nodes and elements equal
837 --------------------------------------------------------------------
838 USERD_get_constant_val
842 Get the value of a constant at a time step
846 float USERD_get_constant_value(int which_var,
851 Value of the requested constant variable
855 (IN) which_var = The variable number
857 (IN) imag_data = TRUE if want imaginary data value.
858 FALSE if want real data value.
862 * Will be based on Current_time_step
866 --------------------------------------------------------------------
867 USERD_get_dataset_query_file_info
871 Get the information about files in the dataset. Used for the
872 dataset query option within EnSight.
876 int USERD_get_dataset_query_file_info(Z_QFILES *qfiles)
881 Z_ERR if not successful
885 (OUT) qfiles = Structure containing information about each file
886 of the dataset. The Z_QFILES structure is defined
887 in the global_extern.h file
889 (The structure will have been allocated
890 Num_dataset_files long, with 10 description
893 qfiles[].name = The name of the file
894 (Z_MAXFILENP is the dimensioned length
897 qfiles[].sizeb = The number of bytes in the file
898 (Typically obtained with a call to the
899 "stat" system routine) (Is a long)
901 qfiles[].timemod = The time the file was last modified
902 (Z_MAXTIMLEN is the dimensioned length
904 (Typically obtained with a call to the
905 "stat" system routine)
907 qfiles[].num_d_lines = The number of description lines you
908 are providing from the file. Max = 10
910 qfiles[].f_desc[] = The description line(s) per file,
911 qfiles[].num_d_lines of them
912 (Z_MAXFILENP is the allocated length of
917 * If Num_dataset_files is 0, this routine will not be called.
918 (See USERD_get_number_of_files_in_dataset)
921 --------------------------------------------------------------------
922 USERD_get_descrip_lines
926 Get two description lines associated with geometry per time step,
927 or one description line associated with a variable per time step.
931 int USERD_get_descrip_lines(int which_type,
940 Z_ERR if not successful
944 (IN) which_type = Z_GEOM for geometry (2 lines)
945 = Z_VARI for variable (1 line)
947 (IN) which_var = If it is a variable, which one.
948 Ignored if geometry type.
950 (IN) imag_data = TRUE if want imaginary data file.
951 FALSE if want real data file.
953 (OUT) line1 = The 1st geometry description line,
954 or the variable description line.
956 (OUT) line2 = The 2nd geometry description line
957 Not used if variable type.
961 * Will be based on Current_time_step
963 * These are the lines EnSight can echo to the screen in
968 --------------------------------------------------------------------
969 USERD_get_element_label_status
973 Answers the question as to whether element labels will be provided.
977 int USERD_get_element_label_status( void )
981 TRUE if element labels will be provided
982 FALSE if element labels will NOT be provided
990 * element lables are needed in order to do any element querying, or
991 element labeling on-screen within EnSight.
993 For unstructured parts, you can read them from your file if
994 available, or can assign them, etc. They need to be unique
995 per part, and are often unique per model.
997 USERD_get_part_element_ids_by_type is used to obtain the ids,
998 on a per part, per type basis, if TRUE status is returned here.
1000 For structured parts, EnSight will assign ids if you return a
1001 status of TRUE here. You cannot assign them youself!!
1004 --------------------------------------------------------------------
1005 USERD_get_geom_timeset_number -
1009 Gets the timeset number to be used for geometry
1013 int USERD_get_geom_timeset_number( void )
1017 Geom_timeset_number = The timeset number that will be used for geometry.
1018 For example, if USERD_get_number_of timesets
1019 returns 2, the valid timeset numbers would be
1028 * If your model is static, which you indicated by returning a zero
1029 in USERD_get_number_of_timesets, you can return a zero here as well.
1033 --------------------------------------------------------------------
1034 USERD_get_gold_part_build_info
1038 Gets the info needed for the part building process.
1042 int USERD_get_gold_part_build_info(int *part_id,
1044 char *part_description[Z_BUFL],
1045 int *number_of_nodes,
1046 int *number_of_elements[Z_MAXTYPE],
1047 int *ijk_dimensions[3],
1048 int *iblanking_options[6])
1053 Z_ERR if not successful
1057 (OUT) part_id = Array containing the external part
1058 ids for each of the model parts.
1061 Parts numbers must be >= 1, because
1062 of the way they are used in the GUI
1064 *******************************************
1065 The ids provided here are the numbers by
1066 which the parts will be referred to in the
1067 GUI (if possible). They are basically
1068 labels as far as you are concerned.
1070 Note: The part numbers you pass to routines
1071 which receive a part_number or block_number
1072 or which_part as an argument are the 1-based
1073 table index of the parts!
1075 example: If Numparts_available = 3
1085 | These are placed in:
1089 | for GUI labeling purposes.
1091 These implied table indices are the part_number,
1092 block_number, or which_part numbers that you would
1093 pass to routines like:
1095 USERD_get_part_coords(int part_number,...
1096 USERD_get_part_node_ids(int part_number,...
1097 USERD_get_part_elements_by_type(int part_number,...
1098 USERD_get_part_element_ids_by_type(int part_number,...
1099 USERD_get_block_coords_by_component(int block_number,...
1100 USERD_get_block_iblanking(int block_number,...
1101 USERD_get_block_ghost_flags(int block_number,...
1102 USERD_get_ghosts_in_block_flag(int block_number)
1103 USERD_get_border_availability( int part_number,...
1104 USERD_get_border_elements_by_type( int part_number,...
1105 USERD_get_var_by_component(int which_variable,
1107 USERD_get_var_value_at_specific(int which_var,
1108 int which_node_or_elem,
1110 ********************************************
1112 (Array will have been allocated
1113 Numparts_available long)
1115 (OUT) part_types = Array containing one of the
1116 following for each model part:
1122 (Array will have been allocated
1123 Numparts_available long)
1125 (OUT) part_description = Array containing a description
1126 for each of the model parts
1128 (Array will have been allocated
1129 Numparts_available by Z_BUFL
1132 (OUT) number_of_nodes = Number of unstructured nodes in the part
1134 (Array will have been allocated
1135 Numparts_available long)
1137 (OUT) number_of_elements = 2D array containing number of
1138 each type of element for each
1139 unstructured model part.
1144 Z_BAR02 = 2-noded bar
1145 Z_BAR03 = 3-noded bar
1146 Z_TRI03 = 3-noded triangle
1147 Z_TRI06 = 6-noded triangle
1148 Z_QUA04 = 4-noded quadrilateral
1149 Z_QUA08 = 8-noded quadrilateral
1150 Z_TET04 = 4-noded tetrahedron
1151 Z_TET10 = 10-noded tetrahedron
1152 Z_PYR05 = 5-noded pyramid
1153 Z_PYR13 = 13-noded pyramid
1154 Z_PEN06 = 6-noded pentahedron
1155 Z_PEN15 = 15-noded pentahedron
1156 Z_HEX08 = 8-noded hexahedron
1157 Z_HEX20 = 20-noded hexahedron
1159 (Ignored unless Z_UNSTRUCTURED type)
1161 (Array will have been allocated
1162 Numparts_available by
1165 (OUT) ijk_dimensions = 2D array containing ijk dimensions
1166 for each structured model part.
1168 (Ignored if Z_UNSTRUCTURED type)
1170 (Array will have been allocated
1171 Numparts_available by 3 long)
1173 ijk_dimensions[][0] = I dimension
1174 ijk_dimensions[][1] = J dimension
1175 ijk_dimensions[][2] = K dimension
1177 (OUT) iblanking_options = 2D array containing iblanking
1178 options possible for each
1179 structured model part.
1181 (Ignored unless Z_IBLANKED type)
1183 (Array will have been allocated
1184 Numparts_available by 6 long)
1186 iblanking_options[][Z_EXT] = TRUE if external (outside)
1187 [][Z_INT] = TRUE if internal (inside)
1188 [][Z_BND] = TRUE if boundary
1189 [][Z_INTBND] = TRUE if internal boundary
1190 [][Z_SYM] = TRUE if symmetry surface
1195 * If you haven't built a table of pointers to the different parts,
1196 you might want to do so here as you gather the needed info.
1198 * Will be based on Current_time_step
1201 --------------------------------------------------------------------
1202 USERD_get_gold_variable_info
1206 Get the variable descriptions, types and filenames
1210 int USERD_get_gold_variable_info(char **var_description,
1211 char **var_filename,
1215 char **var_ifilename,
1223 Z_ERR if not successful
1227 (OUT) var_description = Variable descriptions
1229 (Array will have been allocated
1230 Num_variables by Z_BUFL long)
1232 variable description restrictions:
1233 ----------------------------------
1234 1. Only first 19 characters used in EnSight.
1235 2. Leading and trailing whitespace will be removed by EnSight.
1236 3. Illegal characters will be replaced by underscores.
1237 4. Thay may not start with a numeric digit.
1238 4. No two variables may have the same description.
1241 (OUT) var_filename = Variable real filenames
1243 (Array will have been allocated
1244 Num_variables by Z_BUFL long)
1246 (OUT) var_type = Variable type
1248 (Array will have been allocated
1251 types are: Z_CONSTANT
1257 (OUT) var_classify = Variable classification
1259 (Array will have been allocated
1262 types are: Z_PER_NODE
1265 (OUT) var_complex = TRUE if complex, FALSE otherwise
1267 (Array will have been allocated
1270 (OUT) var_ifilename = Variable imaginary filenames (if complex)
1272 (Array will have been allocated
1273 Num_variables by Z_BUFL long)
1275 (OUT) var_freq = complex frequency (if complex)
1277 (Array will have been allocated
1280 (OUT) var_contran = TRUE if constant changes per time step
1281 FALSE if constant truly same at all time steps
1283 (Array will have been allocated
1286 (OUT) var_timeset = Timeset the variable will use (1 based).
1287 (For static models, set it to 1)
1289 (Array will have been allocated
1292 For example: If USERD_get_number_of_timesets
1293 returns 2, the valid
1294 timeset_number's would be 1 or 2
1299 * The implied variable numbers apply, but be aware that the
1300 arrays are zero based.
1301 So for variable 1, will need to provide var_description[0]
1312 for variable 2, will need to provide var_description[1]
1324 --------------------------------------------------------------------
1325 USERD_get_maxsize_info
1329 Gets maximum part sizes for efficient memory allocation.
1331 Transient models (especially those that increase in size) can cause
1332 reallocations, at time step changes, to keep chewing up more and
1333 more memory. The way to avoid this is to know what the maximum
1334 size of such memory will be, and allocate for this maximum initially.
1336 Accordingly, if you choose to provide this information (it is optional),
1337 EnSight will take advantage of it.
1342 int USERD_get_maxsize_info(int *max_number_of_nodes,
1343 int *max_number_of_elements[Z_MAXTYPE],
1344 int *max_ijk_dimensions[3])
1348 Z_OK if supplying maximum data
1349 Z_ERR if not supplying maximum data, or some error occurred
1350 while trying to obtain it.
1354 (OUT) max_number_of_nodes = Maximum number of unstructured nodes
1355 in the part (over all time).
1357 (Array will have been allocated
1358 Numparts_available long)
1360 (OUT) max_number_of_elements = 2D array containing maximum number of
1361 each type of element for each
1362 unstructured model part (over all time).
1367 Z_BAR02 = 2-noded bar
1368 Z_BAR03 = 3-noded bar
1369 Z_TRI03 = 3-noded triangle
1370 Z_TRI06 = 6-noded triangle
1371 Z_QUA04 = 4-noded quadrilateral
1372 Z_QUA08 = 8-noded quadrilateral
1373 Z_TET04 = 4-noded tetrahedron
1374 Z_TET10 = 10-noded tetrahedron
1375 Z_PYR05 = 5-noded pyramid
1376 Z_PYR13 = 13-noded pyramid
1377 Z_PEN06 = 6-noded pentahedron
1378 Z_PEN15 = 15-noded pentahedron
1379 Z_HEX08 = 8-noded hexahedron
1380 Z_HEX20 = 20-noded hexahedron
1382 (Ignored unless Z_UNSTRUCTURED type)
1384 (Array will have been allocated
1385 Numparts_available by
1388 (OUT) max_ijk_dimensions = 2D array containing maximum ijk dimensions
1389 for each structured model part (over all time).
1391 (Ignored if Z_UNSTRUCTURED type)
1393 (Array will have been allocated
1394 Numparts_available by 3 long)
1396 max_ijk_dimensions[][0] = maximum I dimension
1397 max_ijk_dimensions[][1] = maximum J dimension
1398 max_ijk_dimensions[][2] = maximum K dimension
1402 * You need to have first called USERD_get_number_of_model_parts and
1403 USERD_get_gold_part_build_info, so Numparts_available is known and
1404 so EnSight will know what the type is (Z_UNSTRUCTURED, Z_STRUCTURED,
1405 or Z_IBLANKED) of each part.
1407 * This will NOT be based on Current_time_step - it is to be the maximum
1408 values over all time!!
1410 * This information is optional. If you return Z_ERR, Ensight will still
1411 process things fine, reallocating as needed, etc. However, for
1412 large transient models you will likely use considerably more memory
1413 and take more processing time for the memory reallocations. So, if it
1414 is possible to provide this information "up front", it is recommended
1420 --------------------------------------------------------------------
1421 USERD_get_model_extents
1425 Gets the model bounding box extents. If this routine supplys them
1426 EnSight will not have to spend time doing so. If this routine
1427 returns Z_ERR, EnSight will have to take the time to touch all the
1428 nodes and gather the extent info.
1432 int USERD_get_model_extents(float extents[6])
1437 Z_ERR if not successful (whereupon EnSight will determine by reading
1438 all coords of all parts)
1442 (OUT) extents[0] = min x
1451 * This will be based on Current_time_step
1454 --------------------------------------------------------------------
1455 USERD_get_name_of_reader
1459 Gets the name of your user defined reader. The user interface will
1460 ask for this and include it in the available reader list.
1464 int USERD_get_name_of_reader(char reader_name[Z_MAX_USERD_NAME],
1470 Z_ERR if not successful
1474 (OUT) reader_name = the name of the your reader or data format.
1475 (max length is Z_MAX_USERD_NAME, which is 20)
1477 (OUT) *two_fields = FALSE if only one data field required
1478 in the data dialog of EnSight.
1479 TRUE if two data fields required.
1483 * Always called. Please be sure to provide a name for your custom
1488 --------------------------------------------------------------------
1489 USERD_get_node_label_status
1493 Answers the question as to whether node labels will be provided.
1497 int USERD_get_node_label_status( void )
1501 TRUE if node labels will be provided
1502 FALSE if node labels will NOT be provided
1510 * Node ids are needed in order to do any node querying, or node
1511 labeling on-screen within EnSight.
1513 For unstructured parts, you can read them from your file if
1514 available, or can assign them, etc. They need to be unique
1515 per part, and are often unique per model. They must also be
1516 positive numbers greater than zero.
1518 USERD_get_part_node_ids is used to obtain the ids, if the
1519 status returned here is TRUE.
1521 (Unlike API 1.0, where the connectivity of elements had to be
1522 according to the node ids - API 2.0's element connectivities
1523 are not affected either way by the status here.)
1525 For structured parts, EnSight will assign ids if you return a
1526 status of TRUE here. You cannot assign them yourself!!
1530 --------------------------------------------------------------------
1531 USERD_get_num_of_time_steps
1535 Gets the number of time steps of data available for desired timeset.
1539 int USERD_get_num_of_time_steps( int timeset_number )
1543 Number of time steps in timeset (>0 if okay, <=0 if problems).
1547 (IN) timeset number = the timeset number
1549 For example: If USERD_get_number_of_timesets
1550 returns 2, the valid
1551 timeset_number's would be 1 and 2
1555 * This should be >= 1 1 indicates a static model
1556 >1 indicates a transient model
1558 * Num_time_steps[timeset_number] would be set here
1562 --------------------------------------------------------------------
1563 USERD_get_number_of_files_in_dataset
1567 Get the total number of files in the dataset. Used for the
1568 dataset query option within EnSight.
1572 int USERD_get_number_of_files_in_dataset( void )
1576 The total number of files in the dataset.
1584 * You can be as complete as you want about this. If you don't
1585 care about the dataset query option, return a value of 0
1586 If you only want certain files, you can just include them. But,
1587 you will need to supply the info in USERD_get_dataset_query_file_info
1588 for each file you include here.
1590 * Num_dataset_files would be set here
1594 --------------------------------------------------------------------
1595 USERD_get_number_of_model_parts
1599 Gets the total number of unstructured and structured parts
1600 in the model, for which you can supply information.
1604 int USERD_get_number_of_model_parts( void )
1608 Number of parts (>0 if okay, <=0 if problems).
1616 * If going to have to read down through the parts in order to
1617 know how many, you may want to build a table of pointers to
1618 the various parts, so you can easily get to particular parts in
1619 later processes. If you can simply read the number of parts
1620 at the head of the file, then you would probably not build the
1623 * This routine would set Numparts_available, which is equal to
1624 Num_unstructured_parts + Num_structured_blocks.
1628 --------------------------------------------------------------------
1629 USERD_get_number_of_timesets
1633 Gets the number of timesets used in the model.
1637 int USERD_get_number_of_timesets( void )
1641 Number of timesets in the model
1649 * Num_timesets would be set here
1651 * If you have a static model, both geometry and variables, you should
1652 return a value of zero.
1654 * If you have a transient model, then you should return one or more.
1658 Geometry Variables No. of timesets
1659 --------- ------------------------------ ---------------
1661 static transient, all using same timeset 1
1663 transient transient, all using same timeset as geom 1
1665 static transient, using 3 different timesets 3
1667 transient transient, using 3 different timesets and
1668 none of them the same as the
1672 NOTE: ALL GEOMETRY MUST USE THE SAME TIMESET!!! You will have to provide
1673 the timeset number to use
1675 USERD_get_geom_timeset_number
1677 Variables can use the same timeset as the geometry, or can use
1678 other timesets. More than one variable can use the same timeset.
1680 example: changing geometry at 5 steps, 0.0, 1.0, 2.0, 3.0, 4.0
1681 variable 1 provided at these same five steps
1682 variable 2 provided at 3 steps, 0.5, 1.25, 3.33
1684 This routine should return a value of 2, because only
1685 two different timesets are needed. Timeset 1 would be for the
1686 geometry and variable 1 (they both use it). Timeset 2 would
1687 be for variable 2, which needs its own in this case.
1693 --------------------------------------------------------------------
1694 USERD_get_number_of_variables
1698 Get the number of variables for which you will be providing info.
1702 int USERD_get_number_of_variables( void )
1706 Number of variables (includes constant, scalar, vector and tensor types)
1707 (>=0 if okay, <0 if problem)
1715 *****************************************************************
1716 * Variable numbers, by which references will be made, are implied
1717 here. If you say there are 3 variables, the variable numbers
1718 will be 1, 2, and 3.
1719 *****************************************************************
1721 * Num_variables would be set here
1725 --------------------------------------------------------------------
1726 USERD_get_part_coords
1730 Gets the coordinates for an unstructured part.
1734 int USERD_get_part_coords(int part_number, float **coord_array)
1739 Z_ERR if not successful
1743 (IN) part_number = The part number
1744 (1-based index of part table, namely:
1746 1 ... Numparts_available.
1748 It is NOT the part_id that
1749 is loaded in USERD_get_gold_part_build_info)
1751 (OUT) coord_array = 2D float array which contains,
1752 x,y,z coordinates of each node
1755 (IMPORTANT: The second dimension of this aray is 1-based!!!)
1757 (Array will have been allocated
1758 3 by (number_of_nodes + 1) for the part
1759 long - see USERD_get_gold_part_build_info)
1762 ex) If number_of_nodes = 100
1764 USERD_get_gold_part_build_info
1766 Then the allocated dimensions of the
1767 pointer sent to this routine will be:
1770 Ignore the coord_array[0][0]
1772 coord_array[2][0] locations and start
1773 the node coordinates at:
1786 * Not called unless Num_unstructured_parts is > 0
1788 * Will be based on Current_time_step
1791 --------------------------------------------------------------------
1792 USERD_get_part_element_ids_by_type
1796 Gets the ids for the elements of a particular type for an unstructured part.
1800 int USERD_get_part_element_ids_by_type(int part_number,
1807 Z_ERR if not successful
1811 (IN) part_number = The part number
1812 (1-based index of part table, namely:
1814 1 ... Numparts_available.
1816 It is NOT the part_id that
1817 is loaded in USERD_get_gold_part_build_info)
1819 (IN) element_type = One of the following (See global_extern.h)
1820 Z_POINT node point element
1823 Z_TRI03 3 node triangle
1824 Z_TRI06 6 node triangle
1827 Z_TET04 4 node tetrahedron
1828 Z_TET10 10 node tetrahedron
1829 Z_PYR05 5 node pyramid
1830 Z_PYR13 13 node pyramid
1831 Z_PEN06 6 node pentahedron
1832 Z_PEN15 15 node pentahedron
1833 Z_HEX08 8 node hexahedron
1834 Z_HEX20 20 node hexahedron
1836 (OUT) elemid_array = 1D array containing id of each
1837 element of the type.
1839 (Array will have been allocated
1840 number_of_elements of the type long)
1842 ex) If number_of_elements[Z_TRI03] = 25
1843 number_of_elements[Z_QUA04] = 100
1844 number_of_elements[Z_HEX08] = 30
1846 USERD_get_gold_part_build_info
1848 Then the allocated dimensions available
1849 for this routine will be:
1850 conn_array[25] when called with Z_TRI03
1852 conn_array[100] when called with Z_QUA04
1854 conn_array[30] when called with Z_HEX08
1858 * Not called unless Num_unstructured_parts is > 0 and element
1859 label status is TRUE
1861 * Will be based on Current_time_step
1865 --------------------------------------------------------------------
1866 USERD_get_part_elements_by_type
1870 Gets the connectivities for the elements of a particular type in an
1875 int USERD_get_part_elements_by_type(int part_number,
1882 Z_ERR if not successful
1886 (IN) part_number = The part number
1887 (1-based index of part table, namely:
1889 1 ... Numparts_available.
1891 It is NOT the part_id that
1892 is loaded in USERD_get_gold_part_build_info)
1894 (IN) element_type = One of the following (See global_extern.h)
1895 Z_POINT node point element
1898 Z_TRI03 3 node triangle
1899 Z_TRI06 6 node triangle
1902 Z_TET04 4 node tetrahedron
1903 Z_TET10 10 node tetrahedron
1904 Z_PYR05 5 node pyramid
1905 Z_PYR13 13 node pyramid
1906 Z_PEN06 6 node pentahedron
1907 Z_PEN15 15 node pentahedron
1908 Z_HEX08 8 node hexahedron
1909 Z_HEX20 20 node hexahedron
1911 (OUT) conn_array = 2D array containing connectivity
1912 of each element of the type.
1914 (Array will have been allocated
1915 num_of_elements of the type by
1916 connectivity length of the type)
1918 ex) If number_of_elements[Z_TRI03] = 25
1919 number_of_elements[Z_QUA04] = 100
1920 number_of_elements[Z_HEX08] = 30
1922 USERD_get_gold_part_build_info
1924 Then the allocated dimensions available
1925 for this routine will be:
1926 conn_array[25][3] when called with Z_TRI03
1928 conn_array[100][4] when called with Z_QUA04
1930 conn_array[30][8] when called with Z_HEX08
1934 * Not called unless Num_unstructured_parts is > 0
1936 * Will be based on Current_time_step
1939 --------------------------------------------------------------------
1940 USERD_get_part_node_ids
1944 Gets the node ids of an unstructured part.
1948 int USERD_get_part_node_ids(int part_number, int *nodeid_array)
1953 Z_ERR if not successful
1957 (IN) part_number = The part number
1958 (1-based index of part table, namely:
1960 1 ... Numparts_available.
1962 It is NOT the part_id that
1963 is loaded in USERD_get_gold_part_build_info)
1965 (OUT) nodeid_array = 1D array containing node ids of
1966 each node in the part.
1968 (IMPORTANT: This array is 1-based!!!)
1970 (Array will have been allocated
1971 (number_of_nodes + 1) for the part long
1972 see USERD_get_gold_part_build_info)
1974 ex) If number_of_nodes = 100
1976 USERD_get_gold_part_build_info
1978 Then the allocated dimensions of the
1979 pointer sent to this routine will be:
1982 Ignore the nodeid_array[0] location and start
1992 * Not called unless Num_unstructured_parts is > 0 and node label
1995 * Will be based on Current_time_step
1997 * The ids are purely labels, used when displaying or querying node ids.
1998 However, any node id < 0 will never be displayed
2001 --------------------------------------------------------------------
2002 USERD_get_reader_descrip
2006 Gets the description of the reader, so gui can give more info
2010 int USERD_get_reader_descrip(char descrip[Z_MAXFILENP])
2015 Z_ERR if not successful
2019 (OUT) descrip = the description of the reader (max length is MAXFILENP,
2024 * OPTIONAL ROUTINE! You can have it or not.
2027 --------------------------------------------------------------------
2028 USERD_get_reader_version
2032 Gets the version number of the user defined reader
2036 int USERD_get_reader_version(char version_number[Z_MAX_USERD_NAME])
2041 Z_ERR if not successful (and will assume is version 1.0)
2045 (OUT) version_number = the version number of the reader
2046 (max length is Z_MAX_USERD_NAME, which
2051 * This needs to be "2.000" or greater. Otherwise EnSight will assume
2052 this reader is API 1.0 instead of 2.0
2056 --------------------------------------------------------------------
2061 Get the solution times associated with each time step for
2066 int USERD_get_sol_times(int timeset_number,
2067 float *solution_times)
2072 Z_ERR if not successful
2076 (IN) timeset_number = the timeset number
2078 For example: If USERD_get_number_of_timesets
2079 returns 2, the valid
2080 timeset_number's would be 1 and 2
2082 (OUT) solution_times = 1D array of solution times per time step
2084 (Array will have been allocated
2085 Num_time_steps[timeset_number] long)
2089 * The solution times must be non-negative and increasing.
2093 --------------------------------------------------------------------
2094 USERD_get_timeset_description -
2098 Get the description to associate with the desired timeset.
2102 int USERD_get_timeset_description(int timeset_number,
2103 char timeset_description[Z_BUFL])
2108 Z_ERR if not successful
2112 (IN) timeset_number = the timeset number
2114 For example: If USERD_get_number_of_timesets
2115 returns 2, the valid
2116 timeset_number's would be 1 and 2
2118 (OUT) timeset_description = timeset description string
2123 * A string of NULLs is valid for timeset_description
2128 --------------------------------------------------------------------
2129 USERD_get_var_by_component
2133 Gets the values of a variable component. Both unstructured and structured
2134 parts use this routine.
2137 Get the component value at each node for a given variable in the part.
2140 Get the component value at each element of a specific part and type
2141 for a given variable.
2145 int USERD_get_var_by_component(int which_variable,
2156 Z_ERR if not successful
2158 or: Z_UNDEF, in which case you need not load any values into var_array
2163 (IN) which_variable = The variable number
2165 (IN) which_part Since EnSight Version 7.4
2166 -------------------------
2169 (1-based index of part table, namely:
2171 1 ... Numparts_available.
2173 It is NOT the part_id that
2174 is loaded in USERD_get_gold_part_build_info)
2176 Prior to EnSight Version 7.4
2177 ----------------------------
2178 = The part id This is the part_id label loaded
2179 in USERD_get_gold_part_build_info.
2180 It is NOT the part table index.
2182 (IN) var_type = Z_SCALAR
2184 Z_TENSOR (symmetric tensor)
2185 Z_TENSOR9 (asymmetric tensor)
2189 if Z_PER_NODE: Not used
2191 if Z_PER_ELEM: = The element type
2192 Z_POINT node point element
2195 Z_TRI03 3 node triangle
2196 Z_TRI06 6 node triangle
2199 Z_TET04 4 node tetrahedron
2200 Z_TET10 10 node tetrahedron
2201 Z_PYR05 5 node pyramid
2202 Z_PYR13 13 node pyramid
2203 Z_PEN06 6 node pentahedron
2204 Z_PEN15 15 node pentahedron
2205 Z_HEX08 8 node hexahedron
2206 Z_HEX20 20 node hexahedron
2208 (IN) imag_data = TRUE if imag component
2209 FALSE if real component
2211 (IN) component = The component: (0 if Z_SCALAR)
2214 (0 - 8 if Z_TENSOR9)
2216 * 6 Symmetric Indicies, 0:5 *
2217 * ---------------------------- *
2218 * | 11 12 13 | | 0 3 4 | *
2220 * T = | 22 23 | = | 1 5 | *
2225 * 9 General Indicies, 0:8 *
2226 * ---------------------------- *
2227 * | 11 12 13 | | 0 3 4 | *
2229 * T = | 21 22 23 | = | 6 1 5 | *
2231 * | 31 32 33 | | 7 8 2 | *
2235 -----------------------------------------------------------------------
2236 (IMPORTANT: this array is 1-based for both Z_PER_NODE and Z_PER_ELEM!!!)
2237 -----------------------------------------------------------------------
2239 if Z_PER_NODE: = 1D array containing variable component value
2242 (Array will have been allocated
2243 (number_of_nodes + 1) long)
2245 Info stored in this fashion:
2246 var_array[0] = not used
2247 var_array[1] = var component for node 1 of part
2248 var_array[2] = var_component for node 2 of part
2249 var_array[3] = var_component for node 3 of part
2252 if Z_PER_ELEM: = 1D array containing variable component
2253 value for each element of a particular
2256 (Array will have been allocated
2257 (number_of_elements[which_part][which_type] + 1)
2258 long. See USERD_get_gold_part_build_info)
2260 Info stored in this fashion:
2261 var_array[1] = var component for elem 1 (of part and type)
2262 var_array[2] = var component for elem 2 (of part and type)
2263 var_array[3] = var component for elem 3 (of part and type)
2268 * Not called unless Num_variables is > 0
2270 * The per_node or per_elem classification must be obtainable from the
2271 variable number (a var_classify array needs to be retained)
2273 * Will be based on Current_time_step
2275 * If the variable is not defined for this part, simply return with a
2276 value of Z_UNDEF. EnSight will treat the variable as undefined for
2280 --------------------------------------------------------------------
2281 USERD_get_var_value_at_specific
2286 Get the value of a particular variable at a particular node in a
2287 particular part at a particular time.
2290 Get the value of a particular variable at a particular element of
2291 a particular type in a particular part at a particular time.
2296 int USERD_get_var_value_at_specific(int which_var,
2297 int which_node_or_elem,
2299 int which_elem_type,
2307 Z_ERR if not successful
2311 (IN) which_var = The variable number
2313 (IN) which_node_or_elem
2316 = The node number. This is not the id, but is
2317 the index of the global node
2318 list (1 based), or the block's
2319 node list (1 based).
2321 Thus, coord_array[1]
2325 . |which_node_or_elem index
2330 = The element number. This is not the id, but is
2331 the element number index
2332 of the number_of_element array
2333 (see USERD_get_gold_part_build_info),
2334 or the block's element list (1 based).
2336 Thus, for which_part:
2337 conn_array[which_elem_type][0]
2338 conn_array[which_elem_type][1]
2339 conn_array[which_elem_type][2]
2341 . which_node_or_elem index
2345 (IN) which_part Since EnSight Version 7.4
2346 -------------------------
2349 (1-based index of part table, namely:
2351 1 ... Numparts_available.
2353 It is NOT the part_id that
2354 is loaded in USERD_get_gold_part_build_info)
2356 Prior to EnSight Version 7.4
2357 ----------------------------
2358 = The part id This is the part_id label loaded
2359 in USERD_get_gold_part_build_info.
2360 It is NOT the part table index.
2362 (IN) which_elem_type
2364 If Z_PER_NODE, or block part:
2368 = The element type. This is the element type index
2369 of the number_of_element array
2370 (see USERD_get_gold_part_build_info)
2372 (IN) time_step = The time step
2374 (IN) imag_data = TRUE if want imaginary value.
2375 FALSE if want real value.
2377 (OUT) values = scalar or vector component value(s)
2378 values[0] = scalar or vector[0]
2379 values[1] = vector[1]
2380 values[2] = vector[2]
2385 * This routine is used in node querys over time (or element querys over
2386 time for Z_PER_ELEM variables). If these operations are not critical
2387 to you, this can be a dummy routine.
2389 * The per_node or per_elem classification must be obtainable from the
2390 variable number (a var_classify array needs to be retained)
2392 * The time step given is for the proper variable timeset.
2395 --------------------------------------------------------------------
2400 Receives the geometry and result filenames entered in the data
2401 dialog. The user written code will have to store and use these
2402 as needed. The user written code must manage its own files!!
2406 int USERD_set_filenames(char filename_1[],
2414 Z_ERR if not successful
2418 (IN) filename_1 = the filename entered into the geometry
2419 field of the data dialog.
2421 (IN) filename_2 = the filename entered into the result
2422 field of the data dialog.
2423 (If the two_fields flag in USERD_get_name_of_reader
2424 is FALSE, this will be null string)
2426 (IN) the_path = the path info from the data dialog.
2427 Note: filename_1 and filename_2 have already
2428 had the path prepended to them. This
2429 is provided in case it is needed for
2430 filenames contained in one of the files
2432 (IN) swapbytes = TRUE if should swap bytes when reading data.
2437 * Since you must manage everything from the input that is entered in
2438 these data dialog fields, this is an important routine!
2440 * It may be that you will need to have an executive type file that contains
2441 info and other filenames within it, like EnSight6's case file.
2444 --------------------------------------------------------------------
2445 USERD_set_server_number
2449 Receives the server number of how many total servers.
2453 int USERD_set_server_number(int cur_serv,
2462 (IN) cur_serv = the current server.
2464 (IN) tot_servs = the total number of servers.
2468 * Only useful if your user defined reader is being used with EnSight's
2469 Server-of-Server capability. And even then, it may or may not be
2470 something that you can take advantage of. If your data is already
2471 partitioned in some manner, such that you can access the proper
2472 portions using this information.
2474 For all non-SOS uses, this will simply be 1 of 1
2478 --------------------------------------------------------------------
2479 USERD_set_time_set_and_step
2483 Set the current time step in the desired timeset. All functions that
2484 need time, and that do not explicitly pass it in, will use the timeset
2485 and step set by this routine, if needed.
2489 void USERD_set_time_set_and_step(int timeset_number,
2498 (IN) timeset_number = the timeset number (1 based).
2500 For example: If USERD_get_number_of_timesets
2501 returns 2, the valid timeset_number's
2504 (IN) time_step = The current time step to set
2508 * Current_time_step and Current_timeset would be set here
2512 --------------------------------------------------------------------
2513 USERD_stop_part_building
2517 This routine called when the part building dialog is closed. It is
2518 provided in case you desire to release memory, etc. that was only needed
2519 during the part building process.
2523 void USERD_stop_part_building( void )
2537 ---- end of doucment ----