Initial commit for version 2.0.x patch release
[OpenFOAM-2.0.x.git] / applications / utilities / postProcessing / graphics / ensightFoamReader / README_USERD_2.0
blob93ac1f4fff0d59add85ae4224cf70e14e7ca87db
1 README_USERD_2.0
2 ================
3 --------------------------------------
4 EnSight User Defined Reader Capability   ===> (API 2.0)
5 --------------------------------------
6 A user defined reader capability is included in EnSight which can allow
7 otherwise unsupported structured or unstructured data to be read.  The user
8 defined reader capability utilizes dynamic shared libraries composed of
9 routines defined in this document but produced by you, the user, (or some
10 third party). This capability is currently available for dec, ibm, hp, sgi,
11 sun, linux, alpha linux, and NT servers.
13 Two versions of this API are available starting with EnSight Version 7.2. The
14 1.0 API (which was designed to be friendly to those producing it, but requires
15 more manipulation internally by EnSight) may be a little easier to
16 produce, but requires more memory and processing time.  The 2.0 API is
17 considerably more efficient, and was designed more with that in mind. It
18 requires that all data be provided on a part basis.
20 If you already have a working 1.0 API reader and are happy with it - there is
21 probably no reason to modify it to the 2.0 API unless:
22  - you deal with large models and the memory use and load times are a
23    problem or
24  - you need tensor variable support or
25  - you need complex variable support or
26  - you need multiple timeset capability or
27  _ you want to provide your own "border" elements (as opposed to EnSight's
28                                                     computation of them).
30 If you are producing a new reader, you should consider which will work best
31 for your needs.
34 API 1.0  (defined in README_USERD_1.0 document)
35 =======
36 The original user defined reader API (used with EnSight Versions 6 through
37 7.1) will continue to be supported. (Note that there was a change in the way
38 that the libraries were made at version 7.1 of EnSight, but underlying code
39 was kept the same.) Thus, any readers that work with EnSight 7.1, should still
40 function with EnSight 7.2.
43 API 2.0  (defined in this README_USERD_2.0 document)
44 =======
45 This new API has been defined to be more efficient and includes access to new
46 capabilities of EnSight 7.2.  It lends itself closely to the EnSight "gold"
47 type format.
49 Some of its advantages are::
51  * Most intermediate temporary arrays have been eliminated, such that the user
52    defined routines write directly into internal part structures. This is a
53    considerable improvement in memory use, and improves speed as well since
54    far less memory need be allocated, initialized, etc.
56  * Parts are self contained. Coordinates, connectivity and all variables are
57    provided on a part basis. This eliminates the need for several global to
58    local coordinate mapping operations and the need for node id connectivity
59    hashing.  This can greatly improve the speed at which models are loaded.
61  * Model extents can be provided directly, such that EnSight need not read
62    all the coordinate data at load time.
64  * Tensor variables are supported
66  * Complex variables are supported
68  * A routine is provided as EnSight exits, so cleanup operations such as
69    removing temporary files can be easily accomplished.
71  * Geometry and variables can be provided on different time lines (timesets).
73  * If your data format already provides boundary shell information, you can
74    use it instead of the "border" representation that EnSight would compute.
76 Further discussion on the philosophical differences between the two API's and
77 an efficiency comparison example can be found in the README_1.0_to_2.0 file.
78 This file also contains guidance on necessary changes to modify an existing
79 1.0 API to the new 2.0 API.
82 ****************************************************************************
83 Note: A default dummy_gold reader and an Ensight Gold example of this new 2.0
84       user defined reader API has been included with your EnSight release.
85       Also, the SILO reader included in the release utilizes the 2.0 API. 
87       And while not identical, the API 1.0 readers might be useful to
88       examine as examples.  Many of the routines are the same or similar.
89 ****************************************************************************
92 The process for producing a user defined reader is:
93 ---------------------------------------------------
94 1. Write code for all pertinent routines in the library (Unless someone else
95    has done this for you).
97         This is of course where the work is done by the user.  The word
98         "pertinent" is used because depending on the nature of the data, some
99         of the routines in the library may be dummy routines.
101         The source code for a dummy_gold library and for various other
102         working or sample libraries is copied from the installation CD during
103         installation.  These will be located in directories under:
105         $CEI_HOME/ensight76/user_defined_src/readers
107         examples:
108         --------
109         Basic dummy_gold routines provide skeleton for a new reader
110           $CEI_HOME/ensight76/user_defined_src/readers/dummy_gold
112         Sample library which reads unstructured binary EnSight Gold data
113           $CEI_HOME/ensight76/user_defined_src/readers/ensight_gold
115         You may find it useful to place your library source in this area as
116         well, but are not limited to this location.
118  * ===> The descriptions of each library routine and the order that the
119         routines are called, which is provided in this file, along with
120         the example libraries, should make it possible for you to produce
121         code for your own data reader.  
124 2. Produce the dynamic shared library.
126    This is a compiling and loading process which varies according to
127    the type of machine you are on.  In the user-defined-reader source
128    tree we have tried to isolate the machine dependent parts of the
129    build process using a set of files in the 'config' directory.  In this
130    directory there is a configuration file for each platform on which
131    EnSight is supported.  Before you can compile the installed readers
132    you should run the script called 'init' in the config directory.
134       i.e.  (for UNIX)
135             cd config
136             ./init sgi_6.5_n64
137             cd ..
138             make
140    If you are compiling for Windows NT, there are two options.  If you
141    have the Cygwin GNU utilities installed, you can use GNU make as for
142    Unix.  Otherwise, there is a script called makeall.cmd which will
143    build all of the readers using nmake.  The Makefiles in each reader
144    directory will work using either make or nmake.
146       i.e.  (WIN32 Cygwin)                 (using nmake)
147             cd config                      cd config
148             sh init win32                  cp win32 config
149             cd ..                          cd ..
150                                            mkdir lib
151             make                           makeall.cmd
153    If you have platform-specific portions of code in your reader, the
154    build system defines a set of flags which can be used within
155    #ifdef ... #endif regions in your source, as shown in the table
156    below.
158    Because the readers are now dynamically opened by EnSight, you may
159    have to include dependent libraries on your link-line to avoid having
160    unresolved symbols.  If you are having problems with a reader, start
161    ensight as "ensight7 -readerdbg" and you will get feedback on any
162    problems encountered in loading a reader.  If there are unresolved
163    symbols, you need to find the library which contains the missing
164    symbols and link it into your reader by adding it to the example
165    link commands below.
167    If you choose to use a different build environment for your reader,
168    you should take care to use compatible compilation flags to ensure
169    compatibilty with the EnSight executables, most notably on the SGI
170    and HP-UX 11.0 platforms, which should use the following flags:
172       sgi_6.2_o32: -mips2
173       sgi_6.2_n64: -mips4 -64
174       sgi_6.5_n32: -mips3
175       sgi_6.5_n64: -mips4 -64
176        hp_11.0_32: +DA2.0
177        hp_11.0_64: +DA2.0W
179     ______________________________________________________________________
180    | MACHINE | OS flag               |  SHARED LIBRARY NAME PRODUCED      |
181    |  TYPE   |------------------------------------------------------------|
182    |         |         LD COMMAND USED IN MAKEFILE                        |
183     ======================================================================
184     ______________________________________________________________________
185    | sgi     | -DSGI                 |  libuserd-X.so                     |
186    |         |------------------------------------------------------------|
187    |         | ld -shared -all -o libuserd-X.so libuserd-X.o              |
188     ----------------------------------------------------------------------
189     ______________________________________________________________________
190    | hp      | -DHP                  |  libuserd-X.sl                     |
191    |         |------------------------------------------------------------|
192    |         | ld -b -o libuserd-X.sl libuserd-X.o                        |
193     ----------------------------------------------------------------------
194     ______________________________________________________________________
195    | sun     | -DSUN                 |  libuserd-X.so                     |
196    |         |------------------------------------------------------------|
197    |         | ld -G -o libuserd-X.so libuserd-X.o                        |
198     ----------------------------------------------------------------------
199     ______________________________________________________________________
200    | dec     | -DDEC                 |  libuserd-X.so                     |
201    |         |------------------------------------------------------------|
202    |         | ld -shared -all -o libuserd-X.so libuserd-X.o -lc          |
203     ----------------------------------------------------------------------
204     ______________________________________________________________________
205    | linux   | -DLINUX               |  libuserd-X.so                     |
206    |         |------------------------------------------------------------|
207    |         | ld -shared -o libuserd-X.so libuserd-X.o -lc               |
208     ----------------------------------------------------------------------
209     ______________________________________________________________________
210    | alpha   | -DALINUX              |  libuserd-X.so                     |
211    | linux   |------------------------------------------------------------|
212    |         | ld -shared -o libuserd-X.so libuserd-X.o -lc               |
213     ----------------------------------------------------------------------
214     ______________________________________________________________________
215    | ibm     | -DIBM                 |  libuserd-X.so                     |
216    |         |------------------------------------------------------------|
217    |         | ld -G -o libuserd-X.so libuserd-X.o -bnoentry -bexpall -lc |
218     ----------------------------------------------------------------------
220    Once you have created your library, you should place it in a directory
221    of your choice or in the standard reader location:
223       $CEI_HOME/ensight76/machines/$CEI_ARCH/lib_readers
225    For example, if you created a reader for "mydata", you should create
226    the reader libuserd-mydata.so and place the file in your own reader
227    directory (see section 3 below) or in the standard location:
229       $CEI_HOME/ensight76/machines/$CEI_ARCH/lib_readers/libuserd-mydata.so
232 3. By default EnSight will load all readers found in the directory:
234       $CEI_HOME/ensight76/machines/$CEI_ARCH/lib_readers
236    Files with names "libuserd-X.so" (where X is a name unique to the reader)
237    are assumed to be user-defined readers.
239    There are two methods which can be used to supplement the default
240    behavior.
242    (1) A feature which is useful for site-level or user-level configuration
243        is the optional environment variable $ENSIGHT7_READER.  This
244        variable directs EnSight to load all readers in the specified reader
245        directory (you should probably specify a full path) before loading
246        the built-in readers.  If the same reader exists in both directories
247        (as determined by the name returned by USERD_get_name_of_reader(),
248        NOT by the filename), the locally configured reader will take
249        precedence.
251    (2) A useful feature for end-users is the use of the libuserd-devel
252        reader.  EnSight will search for a reader named libuserd-devel.so
253        (.sl for HP or .dll for NT).  This reader can exist anywhere in the
254        library path (see below) of the user.  This is useful for an
255        individual actively developing a reader because the existence of a
256        libuserd-devel library will take precedence over any other library
257        which returns the same name from USERD_get_name_of_reader().
259    As an example, a site may install commonly used readers in a common
260    location, and users can set the ENSIGHT7_READER variable to access them:
262       setenv ENSIGHT7_READER /usr/local/lib/e7readers
263   
264    A user working on a new reader may compile the reader and place it in
265    a directory specified by the library path:
267       cp libuserd-myreader.so ~/lib/libuserd-devel.so
268       setenv <librarypath> ~/lib:$<librarypath>
270    The user is responsible for correctly configuring the library path
271    variable in order to make use of the libuserd-devel feature.  The
272    library environment variables used are:
274         Machine type    Environment variable to set
275         ------------    ---------------------------
276         sgi             LD_LIBRARY_PATH
277         dec             LD_LIBRARY_PATH
278         sun             LD_LIBRARY_PATH
279         linux           LD_LIBRARY_PATH
280         alpha linux     LD_LIBRARY_PATH
281         hp              SHLIB_PATH
282         ibm             LIBPATH
284 As always, EnSight support is available if you need it.
288 -------------------------------
289 Quick Index of Library Routines
290 -------------------------------
292 Generally Needed for UNSTRUCTURED data
293 --------------------------------------
294 USERD_get_part_coords                         part's node coordinates
295 USERD_get_part_node_ids                       part's node ids
296 USERD_get_part_elements_by_type               part's element connectivites
297 USERD_get_part_element_ids_by_type            part's element ids
300 Generally Needed for BLOCK data
301 --------------------------------------
302 USERD_get_block_coords_by_component           block coordinates
303 USERD_get_block_iblanking                     block iblanking values
306 Generally needed for either or both kinds of data
307 -------------------------------------------------
308 USERD_get_name_of_reader                      name of reader for GUI
309 USERD_get_reader_version                      provide reader version number
310 USERD_get_reader_descrip                      provide GUI more description(optional)
312 USERD_set_filenames                           filenames entered in GUI
313 USERD_set_server_number                       server which of how many
315 USERD_get_number_of_timesets                  number of timesets
316 USERD_get_timeset_description                 description of timeset
317 USERD_get_geom_timeset_number                 timeset # to use for geom
319 USERD_get_num_of_time_steps                   number of time steps
320 USERD_get_sol_times                           solution time values
321 USERD_set_time_set_and_step                   current timeset and time step
324 USERD_get_changing_geometry_status            changing geometry?
325 USERD_get_node_label_status                   node labels?
326 USERD_get_element_label_status                element labels?
327 USERD_get_model_extents                       provide model bounding extents
328 USERD_get_number_of_files_in_dataset          number of files in model
329 USERD_get_dataset_query_file_info             info about each model file
330 USERD_get_descrip_lines                       file associated description lines
331 USERD_get_number_of_model_parts               number of model parts
332 USERD_get_part_build_info                     part/block type/descrip etc.
333 USERD_get_maxsize_info                        part/block allocation maximums
335 USERD_get_border_availability                 part border provided?
336 USERD_get_border_elements_by_type             part border conn and parent info
338 USERD_get_number_of_variables                 number of variables
339 USERD_get_gold_variable_info                  variable type/descrip etc.
340 USERD_get_var_by_component                    part or block variable values
341 USERD_get_constant_val                        constant variable's value
342 USERD_get_var_value_at_specific               node's or element's variable
343                                                  value over time
344 USERD_stop_part_building                      cleanup after part build routine
346 USERD_bkup                                    archive routine
348 USERD_exit_routine                            cleanup upon exit routine
351 -------------------------
352 Order Routines are called
353 -------------------------
355 The various main operations are given basically in the order they will
356 be performed.  Within each operation, the order the routines will be
357 called is given.  
359 1. Setting name in the gui, and specifying one or two input fields
361         USERD_get_name_of_reader
362         USERD_get_reader_descrip    (optional)
364 2. Getting the reader version (also distinguishes between API's)
366         USERD_get_reader_version
368 3. Setting filenames and getting timeset and time info
370         USERD_set_server_number
371         USERD_set_filenames
372         USERD_get_number_of_timesets
373         USERD_get_geom_timeset_number
375         for each timeset:
376           USERD_get_timeset_description
377           USERD_get_num_of_time_steps
378           USERD_get_sol_times
380         USERD_set_time_set_and_step
382 4. Gathering info for part builder
384         USERD_set_time_set_and_step
385         USERD_get_changing_geometry_status
386         USERD_get_node_label_status
387         USERD_get_element_label_status
388         USERD_get_number_of_files_in_dataset
389         USERD_get_dataset_query_file_info
390         USERD_get_descrip_lines                 (for geometry)
391         USERD_get_number_of_model_parts
392         USERD_get_gold_part_build_info
393         USERD_get_maxsize_info
394         USERD_get_model_extents     OR          (for model extents)
395              USERD_get_part_coords  AND/OR
396              USERD_get_block_coords_by_component
398 5. Gathering Variable info
400         USERD_get_number_of_variables
401         USERD_get_gold_variable_info
402               
403 6. Part building (per part created)
405         USERD_set_time_set_and_step
406         USERD_get_part_element_ids_by_type
407         USERD_get_part_elements_by_type
408         USERD_get_part_coords
409         USERD_get_part_node_ids
410         USERD_get_block_iblanking
411         USERD_get_block_coords_by_component
413         USERD_get_border_availability        (If border representation
414         USERD_get_border_elements_by_type     is selected)
416         USERD_stop_part_building      (only once when part builder
417                                        dialog is closed)
419 7. Loading Variables
420           
421         constants:
422         ---------
423         USERD_set_time_set_and_step
424         USERD_get_constant_val
425           
426         scalars/vectors/tensors:
427         ------------------------
428         USERD_get_descrip_lines
429         USERD_set_time_set_and_step
430         USERD_get_var_by_component
432 8. Changing geometry
434         changing coords only (per part):
435         --------------------
436         USERD_set_time_set_and_step
437         USERD_get_descrip_lines
438         USERD_get_part_coords
439         USERD_get_block_coords_by_component
441         changing connectivity (per part):
442         ---------------------
443         USERD_set_time_set_and_step
444         USERD_get_descrip_lines
445         USERD_get_number_of_model_parts
446         USERD_get_gold_part_build_info
447         USERD_get_model_extents   OR
448            USERD_get_part_coords  AND/OR
449            USERD_get_block_coords_by_component
450         USERD_get_part_element_ids_by_type
451         USERD_get_part_elements_by_type
452         USERD_get_part_coords
453         USERD_get_part_node_ids
454         USERD_get_block_iblanking
455         USERD_get_block_coords_by_component
457         USERD_get_border_availability        (If border representation
458         USERD_get_border_elements_by_type     is selected)
460   
461 9. Node or Element queries over time
463         USERD_get_var_value_at_specific
466 -----------------------
467 Detailed Specifications
468 -----------------------
470 Include files:
471 --------------
472 The following header file is required in any file containing these library
473 routines. 
475        #include "global_extern.h"
478 Basis of arrays:
479 ---------------
480 Unless explicitly stated otherwise, all arrays are zero based - in true C
481 fashion.
484 Global variables:
485 ----------------
486 You will generally need to have a few global variables which are shared by
487 the various library routines. The detailed specifications below have assumed
488 the following are available.  (Their names describe their purpose, and they
489 will be used in helping describe the details of the routines below).
491 static int Numparts_available         = 0;
492 static int Num_unstructured_parts     = 0;
493 static int Num_structured_blocks      = 0;
495 /* Note: Numparts_available = Num_unstructured_parts + Num_structured_blocks */
497 static int Num_timesets               = 1;
498 static int Current_timeset            = 1;
499 static int Geom_timeset_number        = 1;
501 static int Num_time_steps[Z_MAXSETS]  = 1;
502 static int Current_time_step          = 0;
503 static int Num_variables              = 0;
504 static int Num_dataset_files          = 0;
506 static int Server_Number              = 1;    Which server of
507 static int Tot_Servers                = 1;    the total number of servers
511 _________________________________________
512 -----------------------------------------
513 Library Routines (in alphabetical order):
514 _________________________________________
515 -----------------------------------------
517 --------------------------------------------------------------------
518 USERD_bkup
520    Description:
521    -----------
522    This routine is called during the EnSight archive process.  You can
523    use it to save or restore info relating to your user defined reader.
525    Specification:
526    -------------
527    int USERD_bkup(FILE *archive_file,
528                   int backup_type)
530    Returns:
531    -------
532    Z_OK  if successful
533    Z_ERR if not successful
535    Arguments:
536    ---------
537    (IN)  archive_file         = The archive file pointer
539    (IN)  backup_type          = Z_SAVE_ARCHIVE for saving archive
540                                 Z_REST_ARCHIVE for restoring archive
542    Notes:
543    -----
544    * Since EnSight's archive file is saved in binary form, you should
545      also do any writing to it or reading from it in binary.
547    * You should archive any variables, which will be needed for
548      future operations, that will not be read or computed again
549      before they will be needed.  These are typically global
550      variables.
552    * Make sure that the number of bytes that you write on a save and
553      the number of bytes that you read on a restore are identical!!
555    * If any of the variables you save are allocated arrays, you must
556      do the allocations before restoring into them.
558 --------------------------------------------------------------------
559 USERD_exit_routine
561    Description:
562    -----------
563    This routine is called as EnSight is exiting. It can be used to clean
564    up anything needed - such as removing temporary files, etc. - or can simply
565    be a dummy.
567    Specification:
568    -------------
569    void USERD_exit_routine( void )
571    Arguments:
572    ---------
573    none
575 --------------------------------------------------------------------
576 USERD_get_block_coords_by_component
578    Description:
579    -----------
580    Get the coordinates of a given structured block, a component at a time.
582    Specification:
583    -------------
584    int USERD_get_block_coords_by_component(int block_number,
585                                            int which_component,
586                                            float *coord_array)
588    Returns:
589    -------
590    Z_OK  if successful
591    Z_ERR if not successful
593    Arguments:
594    ---------
595    (IN)  block_number            = The block part number
596                                     (1-based index of part table, namely:
597   
598                                        1 ... Numparts_available.
599   
600                                      It is NOT the part_id that
601                                      is loaded in USERD_get_gold_part_build_info)
603    (IN)  which_component         = Z_COMPX if x component wanted
604                                  = Z_COMPY if y component wanted
605                                  = Z_COMPZ if z component wanted
607    (OUT) coord_array             = 1D array containing x,y, or z
608                                    coordinate component of each node
610                                   (Array will have been allocated
611                                    i*j*k for the block long)
613    Notes:
614    -----
615    * Not called unless Num_structured_blocks is > 0
617    * Will be based on Current_time_step
621 --------------------------------------------------------------------
622 USERD_get_block_iblanking
624    Description:
625    -----------
626    Get the iblanking value at each node of a block (if the block is
627    iblanked).
629    Specification:
630    -------------
631    int USERD_get_block_iblanking(int block_number,
632                                  int *iblank_array)
634    Returns:
635    -------
636    Z_OK  if successful
637    Z_ERR if not successful
639    Arguments:
640    ---------
641    (IN)  block_number            = The block part number
642                                     (1-based index of part table, namely:
643   
644                                        1 ... Numparts_available.
645   
646                                      It is NOT the part_id that
647                                      is loaded in USERD_get_gold_part_build_info)
649    (OUT) iblank_array            = 1D array containing iblank value
650                                    for each node.
652                                   (Array will have been allocated
653                                    i*j*k for the block long)
655           possible values are:   Z_EXT     = exterior
656                                  Z_INT     = interior
657                                  Z_BND     = boundary
658                                  Z_INTBND  = internal boundary
659                                  Z_SYM     = symmetry plane
661    Notes:
662    -----
663    * Not called unless Num_structured_blocks is > 0  and you have
664      some iblanked blocks
666    * Will be based on Current_time_step
670 --------------------------------------------------------------------
671 USERD_get_border_availability
673    Description:
674    -----------
675    Finds out if border elements are provided by the reader for the
676    desired part, or will need to be computed internally by EnSight.
678    Specification:
679    -------------
680    int USERD_get_border_availability(int part_number,
681                                      int number_of_elements[Z_MAXTYPE])
683    Returns:
684    -------
685    Z_OK  if border elements will be provided by the reader.
686           (number_of_elements array will be loaded and
687            USERD_get_border_elements_by_type will be called)
689    Z_ERR if border elements are not available - thus EnSight must compute.
690           (USERD_get_border_elements_by_type will not be called)
693    Arguments:
694    ---------
695    (IN)  part_number             = The part number
696                                     (1-based index of part table, namely:
697   
698                                        1 ... Numparts_available.
699   
700                                      It is NOT the part_id that
701                                      is loaded in USERD_get_gold_part_build_info)
703    (OUT) number_of_elements     = 2D array containing number of
704                                   each type of border element in
705                                   the part.
706                                   ------------
707                                   Possible types are:
709                                 Z_POINT   =  point
710                                 Z_BAR02   =  2-noded bar
711                                 Z_BAR03   =  3-noded bar
712                                 Z_TRI03   =  3-noded triangle
713                                 Z_TRI06   =  6-noded triangle
714                                 Z_QUA04   =  4-noded quadrilateral
715                                 Z_QUA08   =  8-noded quadrilateral
717    Notes:
718    -----
719    * Only called if border representation is used.
721    * Will be based on Current_time_step
725 --------------------------------------------------------------------
726 USERD_get_border_elements_by_type
728    Description:
729    -----------
730    Provides border element connectivity and parent information. 
732    Specification:
733    -------------
734    int USERD_get_border_elements_by_type(int part_number,
735                                          int element_type,
736                                          int **conn_array,
737                                          short *parent_element_type,
738                                          int *parent_element_num)
740    Returns:
741    -------
742    Z_OK  if successful
743    Z_ERR if not successful
745    Arguments:
746    ---------
747    (IN)  part_number           = The part number
748                                     (1-based index of part table, namely:
749   
750                                        1 ... Numparts_available.
751   
752                                      It is NOT the part_id that
753                                      is loaded in USERD_get_gold_part_build_info)
755    (IN)  element_type          = One of the following (See global_extern.h)
756                                  Z_POINT    node point element
757                                  Z_BAR02    2 node bar
758                                  Z_BAR03    3 node bar
759                                  Z_TRI03    3 node triangle
760                                  Z_TRI06    6 node triangle
761                                  Z_QUA04    4 node quad
762                                  Z_QUA08    8 node quad
764    (OUT) conn_array            = 2D array containing connectivity
765                                  of each border element of the type.
767                                 (Array will have been allocated
768                                  num_of_elements of the type by
769                                  connectivity length of the type)
771                        ex) If number_of_elements[Z_TRI03] = 25
772                               number_of_elements[Z_QUA04] = 100
773                               number_of_elements[Z_QUA08] = 30
774                            as obtained in:
775                             USERD_get_border_availability
777                            Then the allocated dimensions available
778                            for this routine will be:
779                               conn_array[25][3]   when called with Z_TRI03
781                               conn_array[100][4]  when called with Z_QUA04
783                               conn_array[30][8]   when called with Z_QUA08
785    (OUT) parent_element_type   = 1D array containing element type of the
786                                  parent element (the one that the border
787                                  element is a face/edge of).
789                                 (Array will have been allocated
790                                  num_of_elements of the type long)
792    (OUT) parent_element_num   = 1D array containing element number of the
793                                  parent element (the one that the border
794                                  element is a face/edge of).
796                                 (Array will have been allocated
797                                  num_of_elements of the type long)
799    
800    Notes:
801    -----
802    * Not called unless USERD_get_border_availability returned Z_OK
804    * Will be based on Current_time_step
808 --------------------------------------------------------------------
809 USERD_get_changing_geometry_status
811    Description:
812    -----------
813    Gets the changing geometry status for the model
815    Specification:
816    -------------
817    int USERD_get_changing_geometry_status( void )
819    Returns:
820    -------
821    Z_STATIC        if geometry does not change
822    Z_CHANGE_COORDS if changing coordinates only
823    Z_CHANGE_CONN   if changing connectivity
825    Arguments:
826    ---------
827    none
829    Notes:
830    -----
831    * EnSight does not support changing number of parts.  But the
832      coords and/or the connectivity of the parts can change.  Note that
833      a part is allowed to be empty (number of nodes and elements equal
834      to zero).
837 --------------------------------------------------------------------
838 USERD_get_constant_val
840    Description:
841    -----------
842    Get the value of a constant at a time step
844    Specification:
845    -------------
846    float USERD_get_constant_value(int which_var,
847                                   int imag_data)
849    Returns:
850    -------
851    Value of the requested constant variable
853    Arguments:
854    ---------
855    (IN)  which_var            = The variable number
857    (IN)  imag_data            = TRUE if want imaginary data value.
858                                 FALSE if want real data value.
860    Notes:
861    -----
862    * Will be based on Current_time_step
866 --------------------------------------------------------------------
867 USERD_get_dataset_query_file_info
869    Description:
870    -----------
871    Get the information about files in the dataset.  Used for the
872    dataset query option within EnSight.
874    Specification:
875    -------------
876    int USERD_get_dataset_query_file_info(Z_QFILES *qfiles)
878    Returns:
879    -------
880    Z_OK  if successful
881    Z_ERR if not successful
883    Arguments:
884    ---------
885    (OUT) qfiles   = Structure containing information about each file
886                     of the dataset. The Z_QFILES structure is defined
887                     in the global_extern.h file
889                    (The structure will have been allocated
890                     Num_dataset_files long, with 10 description
891                     lines per file).
893       qfiles[].name        = The name of the file
894                              (Z_MAXFILENP is the dimensioned length
895                               of the name)
897       qfiles[].sizeb       = The number of bytes in the file
898                              (Typically obtained with a call to the
899                               "stat" system routine) (Is a long)
901       qfiles[].timemod     = The time the file was last modified 
902                              (Z_MAXTIMLEN is the dimensioned length
903                               of this string)
904                              (Typically obtained with a call to the
905                               "stat" system routine)
907       qfiles[].num_d_lines = The number of description lines you
908                               are providing from the file. Max = 10
910       qfiles[].f_desc[]    = The description line(s) per file,
911                               qfiles[].num_d_lines of them
912                               (Z_MAXFILENP is the allocated length of
913                                each line)
915    Notes:
916    -----
917    * If Num_dataset_files is 0, this routine will not be called.
918      (See USERD_get_number_of_files_in_dataset)
921 --------------------------------------------------------------------
922 USERD_get_descrip_lines
924    Description:
925    -----------
926    Get two description lines associated with geometry per time step,
927    or one description line associated with a variable per time step.
929    Specification:
930    -------------
931    int USERD_get_descrip_lines(int which_type,
932                                int which_var,
933                                int imag_data,
934                                char line1[Z_BUFL],
935                                char line2[Z_BUFL])
937    Returns:
938    -------
939    Z_OK  if successful
940    Z_ERR if not successful
942    Arguments:
943    ---------
944    (IN)  which_type           = Z_GEOM for geometry (2 lines)
945                               = Z_VARI for variable (1 line)
947    (IN)  which_var            = If it is a variable, which one.
948                                 Ignored if geometry type.
950    (IN)  imag_data            = TRUE if want imaginary data file.
951                                 FALSE if want real data file.
953    (OUT) line1                = The 1st geometry description line,
954                                 or the variable description line.
956    (OUT) line2                = The 2nd geometry description line
957                                 Not used if variable type.
959    Notes:
960    -----
961    * Will be based on Current_time_step
963    * These are the lines EnSight can echo to the screen in
964      annotation mode.
968 --------------------------------------------------------------------
969 USERD_get_element_label_status
971    Description:
972    -----------
973    Answers the question as to whether element labels will be provided.
975    Specification:
976    -------------
977    int USERD_get_element_label_status( void )
979    Returns:
980    -------
981    TRUE        if element labels will be provided
982    FALSE       if element labels will NOT be provided
984    Arguments:
985    ---------
986    none
988    Notes:
989    -----
990    * element lables are needed in order to do any element querying, or
991      element labeling on-screen within EnSight.
993        For unstructured parts, you can read them from your file if
994        available, or can assign them, etc. They need to be unique
995        per part, and are often unique per model.
997          USERD_get_part_element_ids_by_type is used to obtain the ids,
998          on a per part, per type basis, if TRUE status is returned here.
1000        For structured parts, EnSight will assign ids if you return a
1001          status of TRUE here.  You cannot assign them youself!!
1004 --------------------------------------------------------------------
1005 USERD_get_geom_timeset_number -
1007    Description:
1008    -----------
1009     Gets the timeset number to be used for geometry
1011    Specification:
1012    -------------
1013    int USERD_get_geom_timeset_number( void )
1015    Returns:
1016    -------
1017    Geom_timeset_number = The timeset number that will be used for geometry.   
1018                          For example, if USERD_get_number_of timesets
1019                          returns 2, the valid timeset numbers would be
1020                          1 or 2.
1022    Arguments:
1023    ---------
1024    none
1026    Notes:
1027    -----
1028    *  If your model is static, which you indicated by returning a zero
1029       in USERD_get_number_of_timesets, you can return a zero here as well.
1033 --------------------------------------------------------------------
1034 USERD_get_gold_part_build_info
1036    Description:
1037    -----------
1038    Gets the info needed for the part building process.
1040    Specification:
1041    -------------
1042    int USERD_get_gold_part_build_info(int *part_id,
1043                                       int *part_types,
1044                                       char *part_description[Z_BUFL],
1045                                       int *number_of_nodes,
1046                                       int *number_of_elements[Z_MAXTYPE],
1047                                       int *ijk_dimensions[3],
1048                                       int *iblanking_options[6])
1050    Returns:
1051    -------
1052    Z_OK  if successful
1053    Z_ERR if not successful
1055    Arguments:
1056    ---------
1057     (OUT) part_id                = Array containing the external part
1058                                    ids for each of the model parts.
1059   
1060                                    IMPORTANT:
1061                                     Parts numbers must be >= 1, because
1062                                     of the way they are used in the GUI
1063   
1064                *******************************************
1065                 The ids provided here are the numbers by
1066                 which the parts will be referred to in the
1067                 GUI (if possible). They are basically
1068                 labels as far as you are concerned.
1069   
1070                 Note: The part numbers you pass to routines
1071                 which receive a part_number or block_number
1072                 or which_part as an argument are the 1-based
1073                 table index of the parts!
1074   
1075                 example:  If Numparts_available = 3
1076   
1077                           Table index        part_id
1078                           -----------        -------
1079                            1                  13
1080                            2                  57
1081                            3                  125
1082   
1083                            ^                   ^
1084                            |                   |
1085                            |                    These are placed in:
1086                            |                      part_id[0] = 13
1087                            |                      part_id[1] = 57
1088                            |                      part_id[2] = 125
1089                            |                    for GUI labeling purposes.
1090                            |
1091                             These implied table indices are the part_number,
1092                             block_number, or which_part numbers that you would
1093                             pass to routines like:
1094   
1095                            USERD_get_part_coords(int part_number,...
1096                            USERD_get_part_node_ids(int part_number,...
1097                            USERD_get_part_elements_by_type(int part_number,...
1098                            USERD_get_part_element_ids_by_type(int part_number,...
1099                            USERD_get_block_coords_by_component(int block_number,...
1100                            USERD_get_block_iblanking(int block_number,...
1101                            USERD_get_block_ghost_flags(int block_number,...
1102                            USERD_get_ghosts_in_block_flag(int block_number)
1103                            USERD_get_border_availability( int part_number,...
1104                            USERD_get_border_elements_by_type( int part_number,...
1105                            USERD_get_var_by_component(int which_variable,
1106                                                       int which_part,...
1107                            USERD_get_var_value_at_specific(int which_var,
1108                                                            int which_node_or_elem,
1109                                                            int which_part,...
1110                ********************************************
1111   
1112                                     (Array will have been allocated
1113                                      Numparts_available long)
1115    (OUT) part_types             = Array containing one of the
1116                                   following for each model part:
1118                                        Z_UNSTRUCTURED or
1119                                        Z_STRUCTURED  or
1120                                        Z_IBLANKED
1122                                   (Array will have been allocated
1123                                    Numparts_available long)
1125    (OUT) part_description       = Array containing a description
1126                                   for each of the model parts
1128                                   (Array will have been allocated
1129                                    Numparts_available by Z_BUFL
1130                                    long)
1132    (OUT) number_of_nodes        = Number of unstructured nodes in the part
1134                                    (Array will have been allocated
1135                                     Numparts_available long)
1137    (OUT) number_of_elements     = 2D array containing number of
1138                                   each type of element for each
1139                                   unstructured model part.
1140                                   ------------
1141                                   Possible types are:
1143                                 Z_POINT   =  point
1144                                 Z_BAR02   =  2-noded bar
1145                                 Z_BAR03   =  3-noded bar
1146                                 Z_TRI03   =  3-noded triangle
1147                                 Z_TRI06   =  6-noded triangle
1148                                 Z_QUA04   =  4-noded quadrilateral
1149                                 Z_QUA08   =  8-noded quadrilateral
1150                                 Z_TET04   =  4-noded tetrahedron
1151                                 Z_TET10   = 10-noded tetrahedron
1152                                 Z_PYR05   =  5-noded pyramid
1153                                 Z_PYR13   = 13-noded pyramid
1154                                 Z_PEN06   =  6-noded pentahedron
1155                                 Z_PEN15   = 15-noded pentahedron
1156                                 Z_HEX08   =  8-noded hexahedron
1157                                 Z_HEX20   = 20-noded hexahedron
1159                                (Ignored unless Z_UNSTRUCTURED type)
1161                                   (Array will have been allocated
1162                                    Numparts_available by
1163                                    Z_MAXTYPE long)
1165    (OUT) ijk_dimensions         = 2D array containing ijk dimensions
1166                                   for each structured model part.
1167                                            ----------
1168                                   (Ignored if Z_UNSTRUCTURED type)
1170                                   (Array will have been allocated
1171                                    Numparts_available by 3 long)
1173                              ijk_dimensions[][0] = I dimension
1174                              ijk_dimensions[][1] = J dimension
1175                              ijk_dimensions[][2] = K dimension
1177    (OUT) iblanking_options      = 2D array containing iblanking
1178                                   options possible for each
1179                                   structured model part.
1180                                   ----------
1181                                   (Ignored unless Z_IBLANKED type)
1183                                   (Array will have been allocated
1184                                    Numparts_available by 6 long)
1186       iblanking_options[][Z_EXT]     = TRUE if external (outside)
1187                        [][Z_INT]     = TRUE if internal (inside)
1188                        [][Z_BND]     = TRUE if boundary
1189                        [][Z_INTBND]  = TRUE if internal boundary
1190                        [][Z_SYM]     = TRUE if symmetry surface
1193    Notes:
1194    -----
1195    * If you haven't built a table of pointers to the different parts,
1196      you might want to do so here as you gather the needed info.
1198    * Will be based on Current_time_step
1201 --------------------------------------------------------------------
1202 USERD_get_gold_variable_info
1204    Description:
1205    -----------
1206    Get the variable descriptions, types and filenames
1208    Specification:
1209    -------------
1210    int USERD_get_gold_variable_info(char **var_description,
1211                                     char **var_filename,
1212                                     int *var_type,
1213                                     int *var_classify,
1214                                     int *var_complex,
1215                                     char **var_ifilename,
1216                                     float *var_freq,
1217                                     int *var_contran,
1218                                     int *var_timeset)
1220    Returns:
1221    -------
1222    Z_OK  if successful
1223    Z_ERR if not successful
1225    Arguments:
1226    ---------
1227    (OUT) var_description      = Variable descriptions
1229                                 (Array will have been allocated
1230                                  Num_variables by Z_BUFL long)
1232            variable description restrictions:
1233            ----------------------------------
1234            1. Only first 19 characters used in EnSight.
1235            2. Leading and trailing whitespace will be removed by EnSight.
1236            3. Illegal characters will be replaced by underscores.
1237            4. Thay may not start with a numeric digit.
1238            4. No two variables may have the same description.
1241    (OUT) var_filename         = Variable real filenames
1243                                 (Array will have been allocated
1244                                  Num_variables by Z_BUFL long)
1246    (OUT) var_type             = Variable type
1248                                 (Array will have been allocated
1249                                  Num_variables long)
1251                                 types are:  Z_CONSTANT
1252                                             Z_SCALAR
1253                                             Z_VECTOR
1254                                             Z_TENSOR
1255                                             Z_TENSOR9
1257    (OUT) var_classify         = Variable classification
1259                                 (Array will have been allocated
1260                                  Num_variables long)
1262                                 types are:  Z_PER_NODE
1263                                             Z_PER_ELEM
1265    (OUT) var_complex          = TRUE if complex, FALSE otherwise
1267                                 (Array will have been allocated
1268                                  Num_variables long)
1270    (OUT) var_ifilename        = Variable imaginary filenames (if complex)
1272                                 (Array will have been allocated
1273                                  Num_variables by Z_BUFL long)
1275    (OUT) var_freq             = complex frequency  (if complex)
1277                                 (Array will have been allocated
1278                                  Num_variables long)
1280    (OUT) var_contran          = TRUE if constant changes per time step
1281                                 FALSE if constant truly same at all time steps
1283                                 (Array will have been allocated
1284                                  Num_variables long)
1286    (OUT) var_timeset          = Timeset the variable will use (1 based).
1287                                 (For static models, set it to 1)
1289                                 (Array will have been allocated
1290                                  Num_variables long)
1292                                  For example:  If USERD_get_number_of_timesets
1293                                                returns 2, the valid
1294                                                timeset_number's would be 1 or 2
1297    Notes:
1298    -----
1299    * The implied variable numbers apply, but be aware that the
1300      arrays are zero based.
1301      So for variable 1, will need to provide   var_description[0]
1302                                                var_filename[0]
1303                                                var_type[0]
1304                                                var_classify[0]
1305                                                var_complex[0]
1306                                                var_ifilename[0]
1307                                                var_freq[0]
1308                                                var_contran[0]
1309                                                var_timeset[0]
1312         for variable 2, will need to provide   var_description[1]
1313                                                var_filename[1]
1314                                                var_type[1]
1315                                                var_classify[1]
1316                                                var_complex[1]
1317                                                var_ifilename[1]
1318                                                var_freq[1]
1319                                                var_contran[1]
1320                                                var_timeset[1]
1321               etc.
1324 --------------------------------------------------------------------
1325 USERD_get_maxsize_info
1327    Description:
1328    -----------
1329    Gets maximum part sizes for efficient memory allocation.
1331    Transient models (especially those that increase in size) can cause
1332    reallocations, at time step changes, to keep chewing up more and
1333    more memory.   The way to avoid this is to know what the maximum
1334    size of such memory will be, and allocate for this maximum initially.
1336    Accordingly, if you choose to provide this information (it is optional),
1337    EnSight will take advantage of it.
1340    Specification:
1341    -------------
1342    int USERD_get_maxsize_info(int *max_number_of_nodes,
1343                               int *max_number_of_elements[Z_MAXTYPE],
1344                               int *max_ijk_dimensions[3])
1346    Returns:
1347    -------
1348    Z_OK  if supplying maximum data
1349    Z_ERR if not supplying maximum data, or some error occurred
1350            while trying to obtain it.
1352    Arguments:
1353    ---------
1354    (OUT) max_number_of_nodes    = Maximum number of unstructured nodes
1355                                   in the part (over all time).
1357                                    (Array will have been allocated
1358                                     Numparts_available long)
1360    (OUT) max_number_of_elements = 2D array containing maximum number of
1361                                   each type of element for each
1362                                   unstructured model part (over all time).
1363                                   ------------
1364                                   Possible types are:
1366                                 Z_POINT   =  point
1367                                 Z_BAR02   =  2-noded bar
1368                                 Z_BAR03   =  3-noded bar
1369                                 Z_TRI03   =  3-noded triangle
1370                                 Z_TRI06   =  6-noded triangle
1371                                 Z_QUA04   =  4-noded quadrilateral
1372                                 Z_QUA08   =  8-noded quadrilateral
1373                                 Z_TET04   =  4-noded tetrahedron
1374                                 Z_TET10   = 10-noded tetrahedron
1375                                 Z_PYR05   =  5-noded pyramid
1376                                 Z_PYR13   = 13-noded pyramid
1377                                 Z_PEN06   =  6-noded pentahedron
1378                                 Z_PEN15   = 15-noded pentahedron
1379                                 Z_HEX08   =  8-noded hexahedron
1380                                 Z_HEX20   = 20-noded hexahedron
1382                                (Ignored unless Z_UNSTRUCTURED type)
1384                                   (Array will have been allocated
1385                                    Numparts_available by
1386                                    Z_MAXTYPE long)
1388    (OUT) max_ijk_dimensions  = 2D array containing maximum ijk dimensions
1389                                for each structured model part (over all time).
1390                                            ----------
1391                                 (Ignored if Z_UNSTRUCTURED type)
1393                                 (Array will have been allocated
1394                                  Numparts_available by 3 long)
1396                              max_ijk_dimensions[][0] = maximum I dimension
1397                              max_ijk_dimensions[][1] = maximum J dimension
1398                              max_ijk_dimensions[][2] = maximum K dimension
1400    Notes:
1401    -----
1402    * You need to have first called USERD_get_number_of_model_parts and
1403      USERD_get_gold_part_build_info, so Numparts_available is known and
1404      so EnSight will know what the type is (Z_UNSTRUCTURED, Z_STRUCTURED,
1405      or Z_IBLANKED) of each part.
1407    * This will NOT be based on Current_time_step - it is to be the maximum
1408      values over all time!!
1410    * This information is optional.  If you return Z_ERR, Ensight will still
1411      process things fine, reallocating as needed, etc.  However, for
1412      large transient models you will likely use considerably more memory
1413      and take more processing time for the memory reallocations. So, if it
1414      is possible to provide this information "up front", it is recommended
1415      to do so.
1420 --------------------------------------------------------------------
1421 USERD_get_model_extents
1423    Description:
1424    -----------
1425    Gets the model bounding box extents.  If this routine supplys them
1426    EnSight will not have to spend time doing so.  If this routine
1427    returns Z_ERR, EnSight will have to take the time to touch all the
1428    nodes and gather the extent info.
1430    Specification:
1431    -------------
1432    int USERD_get_model_extents(float extents[6])
1434    Returns:
1435    -------
1436    Z_OK  if successful
1437    Z_ERR if not successful  (whereupon EnSight will determine by reading
1438                              all coords of all parts)
1440    Arguments:
1441    ---------
1442    (OUT) extents[0]   = min x
1443                 [1]   = max x
1444                 [2]   = min y
1445                 [3]   = max y
1446                 [4]   = min z
1447                 [5]   = max z
1449    Notes:
1450    -----
1451    * This will be based on Current_time_step
1454 --------------------------------------------------------------------
1455 USERD_get_name_of_reader
1457    Description:
1458    -----------
1459    Gets the name of your user defined reader.  The user interface will
1460    ask for this and include it in the available reader list.
1462    Specification:
1463    -------------
1464    int USERD_get_name_of_reader(char reader_name[Z_MAX_USERD_NAME],
1465                                 int *two_fields)
1467    Returns:
1468    -------
1469    Z_OK  if successful
1470    Z_ERR if not successful
1472    Arguments:
1473    ---------
1474    (OUT) reader_name          = the name of the your reader or data format.
1475                               (max length is Z_MAX_USERD_NAME, which is 20)
1477    (OUT) *two_fields          = FALSE if only one data field required
1478                                       in the data dialog of EnSight.
1479                                 TRUE if two data fields required.
1481    Notes:
1482    -----
1483    * Always called.  Please be sure to provide a name for your custom
1484      reader format.
1488 --------------------------------------------------------------------
1489 USERD_get_node_label_status
1491    Description:
1492    -----------
1493    Answers the question as to whether node labels will be provided.
1495    Specification:
1496    -------------
1497    int USERD_get_node_label_status( void )
1499    Returns:
1500    -------
1501    TRUE        if node labels will be provided
1502    FALSE       if node labels will NOT be provided
1504    Arguments:
1505    ---------
1506    none
1508    Notes:
1509    -----
1510    * Node ids are needed in order to do any node querying, or node
1511      labeling on-screen within EnSight.
1513        For unstructured parts, you can read them from your file if
1514        available, or can assign them, etc. They need to be unique
1515        per part, and are often unique per model.  They must also be
1516        positive numbers greater than zero.
1518          USERD_get_part_node_ids is used to obtain the ids, if the
1519          status returned here is TRUE.
1521          (Unlike API 1.0, where the connectivity of elements had to be
1522           according to the node ids - API 2.0's element connectivities
1523           are not affected either way by the status here.)
1525        For structured parts, EnSight will assign ids if you return a
1526          status of TRUE here.  You cannot assign them yourself!!
1530 --------------------------------------------------------------------
1531 USERD_get_num_of_time_steps
1533    Description:
1534    -----------
1535    Gets the number of time steps of data available for desired timeset.
1537    Specification:
1538    -------------
1539    int USERD_get_num_of_time_steps( int timeset_number )
1541    Returns:
1542    -------
1543    Number of time steps in timeset  (>0 if okay, <=0 if problems).
1545    Arguments:
1546    ---------
1547    (IN) timeset number = the timeset number
1549                          For example: If USERD_get_number_of_timesets
1550                                       returns 2, the valid
1551                                       timeset_number's would be 1 and 2
1553    Notes:
1554    -----
1555    * This should be >= 1       1 indicates a static model
1556                               >1 indicates a transient model
1558    * Num_time_steps[timeset_number] would be set here
1562 --------------------------------------------------------------------
1563 USERD_get_number_of_files_in_dataset
1565    Description:
1566    -----------
1567    Get the total number of files in the dataset.  Used for the
1568    dataset query option within EnSight.
1570    Specification:
1571    -------------
1572    int USERD_get_number_of_files_in_dataset( void )
1574    Returns:
1575    -------
1576    The total number of files in the dataset.
1578    Arguments:
1579    ---------
1580    none
1582    Notes:
1583    -----
1584    * You can be as complete as you want about this.  If you don't
1585      care about the dataset query option, return a value of 0
1586      If you only want certain files, you can just include them. But,
1587      you will need to supply the info in USERD_get_dataset_query_file_info
1588      for each file you include here.
1590    * Num_dataset_files would be set here
1594 --------------------------------------------------------------------
1595 USERD_get_number_of_model_parts
1597    Description:
1598    -----------
1599    Gets the total number of unstructured and structured parts
1600    in the model, for which you can supply information.
1602    Specification:
1603    -------------
1604    int USERD_get_number_of_model_parts( void )
1606    Returns:
1607    -------
1608    Number of parts  (>0 if okay, <=0 if problems).
1610    Arguments:
1611    ---------
1612    none
1614    Notes:
1615    -----
1616    * If going to have to read down through the parts in order to
1617      know how many, you may want to build a table of pointers to
1618      the various parts, so you can easily get to particular parts in
1619      later processes.  If you can simply read the number of parts
1620      at the head of the file, then you would probably not build the
1621      table at this time.
1623    * This routine would set Numparts_available, which is equal to
1624      Num_unstructured_parts + Num_structured_blocks.
1628 --------------------------------------------------------------------
1629 USERD_get_number_of_timesets
1631    Description:
1632    -----------
1633     Gets the number of timesets used in the model.
1635    Specification:
1636    -------------
1637    int USERD_get_number_of_timesets( void )
1639    Returns:
1640    -------
1641    Number of timesets in the model
1643    Arguments:
1644    ---------
1645    none
1647    Notes:
1648    -----
1649    * Num_timesets would be set here
1651    * If you have a static model, both geometry and variables, you should
1652      return a value of zero.
1654    * If you have a transient model, then you should return one or more.
1656    For example:
1658       Geometry    Variables                                 No. of timesets
1659       ---------   ------------------------------            ---------------
1660       static      static                                      0
1661       static      transient, all using same timeset           1
1663       transient   transient, all using same timeset as geom   1
1665       static      transient, using 3 different timesets       3
1667       transient   transient, using 3 different timesets and
1668                              none of them the same as the
1669                              geometry timeset                 4
1670           etc.
1672    NOTE: ALL GEOMETRY MUST USE THE SAME TIMESET!!! You will have to provide
1673                                                    the timeset number to use
1674                                                    for geometry in:
1675                                                USERD_get_geom_timeset_number
1677          Variables can use the same timeset as the geometry, or can use
1678          other timesets. More than one variable can use the same timeset.
1680    example:  changing geometry at 5 steps, 0.0, 1.0, 2.0, 3.0, 4.0
1681              variable 1 provided at these same five steps
1682              variable 2 provided at 3 steps, 0.5, 1.25, 3.33
1684         This routine should return a value of 2, because only
1685         two different timesets are needed. Timeset 1 would be for the
1686         geometry and variable 1 (they both use it). Timeset 2 would
1687         be for variable 2, which needs its own in this case.
1693 --------------------------------------------------------------------
1694 USERD_get_number_of_variables
1696    Description:
1697    -----------
1698    Get the number of variables for which you will be providing info.
1700    Specification:
1701    -------------
1702    int USERD_get_number_of_variables( void )
1704    Returns:
1705    -------
1706    Number of variables (includes constant, scalar, vector and tensor types)
1707                        (>=0 if okay, <0 if problem)
1709    Arguments:
1710    ---------
1711    none
1713    Notes:
1714    -----
1715     *****************************************************************
1716    * Variable numbers, by which references will be made, are implied
1717      here. If you say there are 3 variables, the variable numbers
1718      will be 1, 2, and 3.
1719     *****************************************************************
1721    * Num_variables would be set here
1725 --------------------------------------------------------------------
1726 USERD_get_part_coords
1728    Description:
1729    -----------
1730    Gets the coordinates for an unstructured part.
1732    Specification:
1733    -------------
1734    int USERD_get_part_coords(int part_number, float **coord_array)
1736    Returns:
1737    -------
1738    Z_OK  if successful
1739    Z_ERR if not successful
1741    Arguments:
1742    ---------
1743    (IN)  part_number             = The part number
1744                                     (1-based index of part table, namely:
1745   
1746                                        1 ... Numparts_available.
1747   
1748                                      It is NOT the part_id that
1749                                      is loaded in USERD_get_gold_part_build_info)
1751    (OUT) coord_array             = 2D float array which contains,
1752                                    x,y,z coordinates of each node
1753                                    in the part.
1755        (IMPORTANT: The second dimension of this aray is 1-based!!!)
1757                                 (Array will have been allocated
1758                                  3 by (number_of_nodes + 1) for the part
1759                                  long - see USERD_get_gold_part_build_info)
1762                        ex) If number_of_nodes = 100
1763                            as obtained in:
1764                              USERD_get_gold_part_build_info
1766                            Then the allocated dimensions of the
1767                            pointer sent to this routine will be:
1768                              coord_array[3][101]
1770                            Ignore the coord_array[0][0]
1771                                       coord_array[1][0]
1772                                       coord_array[2][0] locations and start
1773                            the node coordinates at:
1774                              coord_array[0][1]
1775                              coord_array[1][1]
1776                              coord_array[2][1]
1778                              coord_array[0][2]
1779                              coord_array[1][2]
1780                              coord_array[2][2]
1782                                    etc.
1784    Notes:
1785    -----
1786    * Not called unless Num_unstructured_parts is > 0
1788    * Will be based on Current_time_step
1791 --------------------------------------------------------------------
1792 USERD_get_part_element_ids_by_type
1794    Description:
1795    -----------
1796    Gets the ids for the elements of a particular type for an unstructured part.
1798    Specification:
1799    -------------
1800    int USERD_get_part_element_ids_by_type(int part_number,
1801                                           int element_type,
1802                                           int *elemid_array)
1804    Returns:
1805    -------
1806    Z_OK  if successful
1807    Z_ERR if not successful
1809    Arguments:
1810    ---------
1811    (IN)  part_number             = The part number
1812                                     (1-based index of part table, namely:
1813   
1814                                        1 ... Numparts_available.
1815   
1816                                      It is NOT the part_id that
1817                                      is loaded in USERD_get_gold_part_build_info)
1819    (IN)  element_type            = One of the following (See global_extern.h)
1820                                    Z_POINT    node point element
1821                                    Z_BAR02    2 node bar
1822                                    Z_BAR03    3 node bar
1823                                    Z_TRI03    3 node triangle
1824                                    Z_TRI06    6 node triangle
1825                                    Z_QUA04    4 node quad
1826                                    Z_QUA08    8 node quad
1827                                    Z_TET04    4 node tetrahedron
1828                                    Z_TET10   10 node tetrahedron
1829                                    Z_PYR05    5 node pyramid
1830                                    Z_PYR13   13 node pyramid
1831                                    Z_PEN06    6 node pentahedron
1832                                    Z_PEN15   15 node pentahedron
1833                                    Z_HEX08    8 node hexahedron
1834                                    Z_HEX20   20 node hexahedron
1836    (OUT) elemid_array            = 1D array containing id of each
1837                                    element of the type.
1839                                   (Array will have been allocated
1840                                    number_of_elements of the type long)
1842                        ex) If number_of_elements[Z_TRI03] = 25
1843                               number_of_elements[Z_QUA04] = 100
1844                               number_of_elements[Z_HEX08] = 30
1845                            as obtained in:
1846                             USERD_get_gold_part_build_info
1848                            Then the allocated dimensions available
1849                            for this routine will be:
1850                               conn_array[25]   when called with Z_TRI03
1852                               conn_array[100]  when called with Z_QUA04
1854                               conn_array[30]  when called with Z_HEX08
1856    Notes:
1857    -----
1858    * Not called unless Num_unstructured_parts is > 0  and element
1859      label status is TRUE
1861    * Will be based on Current_time_step
1865 --------------------------------------------------------------------
1866 USERD_get_part_elements_by_type
1868    Description:
1869    -----------
1870    Gets the connectivities for the elements of a particular type in an
1871    unstructured part
1873    Specification:
1874    -------------
1875    int USERD_get_part_elements_by_type(int part_number,
1876                                        int element_type,
1877                                        int **conn_array)
1879    Returns:
1880    -------
1881    Z_OK  if successful
1882    Z_ERR if not successful
1884    Arguments:
1885    ---------
1886    (IN)  part_number           = The part number
1887                                     (1-based index of part table, namely:
1888   
1889                                        1 ... Numparts_available.
1890   
1891                                      It is NOT the part_id that
1892                                      is loaded in USERD_get_gold_part_build_info)
1894    (IN)  element_type          = One of the following (See global_extern.h)
1895                                  Z_POINT    node point element
1896                                  Z_BAR02    2 node bar
1897                                  Z_BAR03    3 node bar
1898                                  Z_TRI03    3 node triangle
1899                                  Z_TRI06    6 node triangle
1900                                  Z_QUA04    4 node quad
1901                                  Z_QUA08    8 node quad
1902                                  Z_TET04    4 node tetrahedron
1903                                  Z_TET10   10 node tetrahedron
1904                                  Z_PYR05    5 node pyramid
1905                                  Z_PYR13   13 node pyramid
1906                                  Z_PEN06    6 node pentahedron
1907                                  Z_PEN15   15 node pentahedron
1908                                  Z_HEX08    8 node hexahedron
1909                                  Z_HEX20   20 node hexahedron
1911    (OUT) conn_array            = 2D array containing connectivity
1912                                  of each element of the type.
1914                                 (Array will have been allocated
1915                                  num_of_elements of the type by
1916                                  connectivity length of the type)
1918                        ex) If number_of_elements[Z_TRI03] = 25
1919                               number_of_elements[Z_QUA04] = 100
1920                               number_of_elements[Z_HEX08] = 30
1921                            as obtained in:
1922                             USERD_get_gold_part_build_info
1924                            Then the allocated dimensions available
1925                            for this routine will be:
1926                               conn_array[25][3]   when called with Z_TRI03
1928                               conn_array[100][4]  when called with Z_QUA04
1930                               conn_array[30][8]   when called with Z_HEX08
1931    
1932    Notes:
1933    -----
1934    * Not called unless Num_unstructured_parts is > 0
1936    * Will be based on Current_time_step
1939 --------------------------------------------------------------------
1940 USERD_get_part_node_ids
1942    Description:
1943    -----------
1944    Gets the node ids of an unstructured part.
1946    Specification:
1947    -------------
1948    int USERD_get_part_node_ids(int part_number, int *nodeid_array)
1950    Returns:
1951    -------
1952    Z_OK  if successful
1953    Z_ERR if not successful
1955    Arguments:
1956    ---------
1957    (IN)  part_number             = The part number
1958                                     (1-based index of part table, namely:
1959   
1960                                        1 ... Numparts_available.
1961   
1962                                      It is NOT the part_id that
1963                                      is loaded in USERD_get_gold_part_build_info)
1965    (OUT) nodeid_array            = 1D array containing node ids of
1966                                     each node in the part.
1968            (IMPORTANT: This array is 1-based!!!)
1970                                    (Array will have been allocated
1971                                     (number_of_nodes + 1) for the part long
1972                                     see USERD_get_gold_part_build_info)
1974                        ex) If number_of_nodes = 100
1975                            as obtained in:
1976                              USERD_get_gold_part_build_info
1978                            Then the allocated dimensions of the
1979                            pointer sent to this routine will be:
1980                              nodeid_array[101]
1982                            Ignore the nodeid_array[0] location and start
1983                            the node ids at:
1984                              nodeid_array[1]
1986                              nodeid_array[2]
1988                                    etc.
1990    Notes:
1991    -----
1992    * Not called unless Num_unstructured_parts is > 0  and node label
1993      status is TRUE
1995    * Will be based on Current_time_step
1997    * The ids are purely labels, used when displaying or querying node ids.
1998      However, any node id < 0 will never be displayed
2001 --------------------------------------------------------------------
2002 USERD_get_reader_descrip
2004    Description:
2005    -----------
2006    Gets the description of the reader, so gui can give more info
2008    Specification:
2009    -------------
2010    int USERD_get_reader_descrip(char descrip[Z_MAXFILENP])
2012    Returns:
2013    -------
2014    Z_OK  if successful
2015    Z_ERR if not successful
2017    Arguments:
2018    ---------
2019    (OUT) descrip  = the description of the reader (max length is MAXFILENP,
2020                                                    which is 255)
2022    Notes:
2023    -----
2024    * OPTIONAL ROUTINE!   You can have it or not.
2027 --------------------------------------------------------------------
2028 USERD_get_reader_version
2030    Description:
2031    -----------
2032    Gets the version number of the user defined reader
2034    Specification:
2035    -------------
2036    int USERD_get_reader_version(char version_number[Z_MAX_USERD_NAME])
2038    Returns:
2039    -------
2040    Z_OK  if successful
2041    Z_ERR if not successful (and will assume is version 1.0)
2043    Arguments:
2044    ---------
2045    (OUT) version_number       = the version number of the reader
2046                                 (max length is Z_MAX_USERD_NAME, which
2047                                  is 20)
2049    Notes:
2050    -----
2051    * This needs to be "2.000" or greater. Otherwise EnSight will assume
2052      this reader is API 1.0 instead of 2.0
2056 --------------------------------------------------------------------
2057 USERD_get_sol_times
2059    Description:
2060    -----------
2061    Get the solution times associated with each time step for 
2062    desired timeset.
2064    Specification:
2065    -------------
2066    int USERD_get_sol_times(int timeset_number,
2067                            float *solution_times)
2069    Returns:
2070    -------
2071    Z_OK  if successful
2072    Z_ERR if not successful
2074    Arguments:
2075    ---------
2076    (IN)  timeset_number     = the timeset number
2078                               For example: If USERD_get_number_of_timesets
2079                                            returns 2, the valid
2080                                            timeset_number's would be 1 and 2
2082    (OUT) solution_times       = 1D array of solution times per time step
2084                                   (Array will have been allocated
2085                                    Num_time_steps[timeset_number] long)
2087    Notes:
2088    -----
2089    * The solution times must be non-negative and increasing.
2093 --------------------------------------------------------------------
2094 USERD_get_timeset_description -
2096    Description:
2097    -----------
2098    Get the description to associate with the desired timeset.
2100    Specification:
2101    -------------
2102    int USERD_get_timeset_description(int timeset_number,
2103                                      char timeset_description[Z_BUFL])
2105    Returns:
2106    -------
2107    Z_OK  if successful
2108    Z_ERR if not successful
2110    Arguments:
2111    ---------
2112    (IN)  timeset_number     = the timeset number
2114                               For example: If USERD_get_number_of_timesets
2115                                            returns 2, the valid
2116                                            timeset_number's would be 1 and 2
2118    (OUT) timeset_description  = timeset description string
2121    Notes:
2122    -----
2123    * A string of NULLs is valid for timeset_description
2128 --------------------------------------------------------------------
2129 USERD_get_var_by_component
2131    Description:
2132    -----------
2133    Gets the values of a variable component.  Both unstructured and structured
2134    parts use this routine.
2136    if Z_PER_NODE:
2137      Get the component value at each node for a given variable in the part.
2139    or if Z_PER_ELEM:
2140      Get the component value at each element of a specific part and type
2141      for a given variable.
2143    Specification:
2144    -------------
2145    int USERD_get_var_by_component(int which_variable,
2146                                   int which_part,
2147                                   int var_type,
2148                                   int which_type,
2149                                   int imag_data,
2150                                   int component,
2151                                   float *var_array)
2153    Returns:
2154    -------
2155    Z_OK  if successful
2156    Z_ERR if not successful
2158    or:  Z_UNDEF, in which case you need not load any values into var_array
2161    Arguments:
2162    ---------
2163    (IN)  which_variable          = The variable number
2165    (IN)  which_part                 Since EnSight Version 7.4
2166                                     -------------------------
2167                                   = The part number
2168   
2169                                     (1-based index of part table, namely:
2170   
2171                                        1 ... Numparts_available.
2172   
2173                                      It is NOT the part_id that
2174                                      is loaded in USERD_get_gold_part_build_info)
2175   
2176                                     Prior to EnSight Version 7.4
2177                                     ----------------------------
2178                                   = The part id   This is the part_id label loaded
2179                                                   in USERD_get_gold_part_build_info.
2180                                                   It is NOT the part table index.
2182    (IN)  var_type                = Z_SCALAR
2183                                    Z_VECTOR
2184                                    Z_TENSOR   (symmetric tensor)
2185                                    Z_TENSOR9  (asymmetric tensor)
2187    (IN)  which_type
2189             if Z_PER_NODE:         Not used
2191             if Z_PER_ELEM:       = The element type
2192                                    Z_POINT    node point element
2193                                    Z_BAR02    2 node bar
2194                                    Z_BAR03    3 node bar
2195                                    Z_TRI03    3 node triangle
2196                                    Z_TRI06    6 node triangle
2197                                    Z_QUA04    4 node quad
2198                                    Z_QUA08    8 node quad
2199                                    Z_TET04    4 node tetrahedron
2200                                    Z_TET10   10 node tetrahedron
2201                                    Z_PYR05    5 node pyramid
2202                                    Z_PYR13   13 node pyramid
2203                                    Z_PEN06    6 node pentahedron
2204                                    Z_PEN15   15 node pentahedron
2205                                    Z_HEX08    8 node hexahedron
2206                                    Z_HEX20   20 node hexahedron
2208    (IN)  imag_data               = TRUE if imag component
2209                                    FALSE if real component
2211    (IN)  component               = The component: (0       if Z_SCALAR)
2212                                                   (0 - 2   if Z_VECTOR)
2213                                                   (0 - 5   if Z_TENSOR)
2214                                                   (0 - 8   if Z_TENSOR9)
2216                                  * 6 Symmetric Indicies, 0:5    *
2217                                  * ---------------------------- *
2218                                  *     | 11 12 13 |   | 0 3 4 | *
2219                                  *     |          |   |       | *
2220                                  * T = |    22 23 | = |   1 5 | *
2221                                  *     |          |   |       | *
2222                                  *     |       33 |   |     2 | *
2225                                  * 9 General   Indicies, 0:8    *
2226                                  * ---------------------------- *
2227                                  *     | 11 12 13 |   | 0 3 4 | *
2228                                  *     |          |   |       | *
2229                                  * T = | 21 22 23 | = | 6 1 5 | *
2230                                  *     |          |   |       | *
2231                                  *     | 31 32 33 |   | 7 8 2 | *
2233    (OUT) var_array 
2235       -----------------------------------------------------------------------
2236       (IMPORTANT: this array is 1-based for both Z_PER_NODE and Z_PER_ELEM!!!)
2237       -----------------------------------------------------------------------
2239             if Z_PER_NODE:    = 1D array containing variable component value
2240                                 for each node.
2242                                 (Array will have been allocated
2243                                  (number_of_nodes + 1) long)
2245                       Info stored in this fashion:
2246                             var_array[0] = not used
2247                             var_array[1] = var component for node 1 of part
2248                             var_array[2] = var_component for node 2 of part
2249                             var_array[3] = var_component for node 3 of part
2250                             etc.
2252             if Z_PER_ELEM:    = 1D array containing variable component
2253                                 value for each element of a particular
2254                                 part and type.
2255                                     
2256                               (Array will have been allocated
2257                                (number_of_elements[which_part][which_type] + 1)
2258                                 long.  See USERD_get_gold_part_build_info)
2260                   Info stored in this fashion:
2261                     var_array[1] = var component for elem 1 (of part and type)
2262                     var_array[2] = var component for elem 2 (of part and type)
2263                     var_array[3] = var component for elem 3 (of part and type)
2264                     etc.
2266    Notes:
2267    -----
2268    * Not called unless Num_variables is > 0
2270    * The per_node or per_elem classification must be obtainable from the
2271      variable number (a var_classify array needs to be retained)
2273    * Will be based on Current_time_step
2275    * If the variable is not defined for this part, simply return with a
2276      value of Z_UNDEF.  EnSight will treat the variable as undefined for
2277      this part.
2280 --------------------------------------------------------------------
2281 USERD_get_var_value_at_specific
2283    Description:
2284    -----------
2285    if Z_PER_NODE:
2286      Get the value of a particular variable at a particular node in a
2287      particular part at a particular time.
2289    or if Z_PER_ELEM:
2290      Get the value of a particular variable at a particular element of
2291      a particular type in a particular part at a particular time.
2294    Specification:
2295    -------------
2296    int USERD_get_var_value_at_specific(int which_var,
2297                                        int which_node_or_elem,
2298                                        int which_part,
2299                                        int which_elem_type,
2300                                        int time_step,
2301                                        float values[3],
2302                                        int imag_data)
2304    Returns:
2305    -------
2306    Z_OK  if successful
2307    Z_ERR if not successful
2309    Arguments:
2310    ---------
2311    (IN)  which_var   = The variable number
2313    (IN)  which_node_or_elem
2315               If Z_PER_NODE:
2316                 = The node number.  This is not the id, but is
2317                                     the index of the global node 
2318                                     list (1 based), or the block's
2319                                     node list (1 based).
2321                   Thus,  coord_array[1]
2322                          coord_array[2]
2323                          coord_array[3]
2324                               .      |
2325                               .      |which_node_or_elem index
2326                               .             ----
2329               If Z_PER_ELEM:
2330                 = The element number.  This is not the id, but is
2331                                        the element number index
2332                                        of the number_of_element array
2333                                        (see USERD_get_gold_part_build_info),
2334                                         or the block's element list (1 based).
2336                   Thus,  for which_part:
2337                          conn_array[which_elem_type][0]
2338                          conn_array[which_elem_type][1]
2339                          conn_array[which_elem_type][2]
2340                               .                      |
2341                               .          which_node_or_elem index
2342                               .                        ----
2345    (IN)  which_part                 Since EnSight Version 7.4
2346                                     -------------------------
2347                                   = The part number
2348   
2349                                     (1-based index of part table, namely:
2350   
2351                                        1 ... Numparts_available.
2352   
2353                                      It is NOT the part_id that
2354                                      is loaded in USERD_get_gold_part_build_info)
2355   
2356                                     Prior to EnSight Version 7.4
2357                                     ----------------------------
2358                                   = The part id   This is the part_id label loaded
2359                                                   in USERD_get_gold_part_build_info.
2360                                                   It is NOT the part table index.
2362    (IN)  which_elem_type
2364               If Z_PER_NODE, or block part:
2365                 = Not used
2367               If Z_PER_ELEM:
2368                 = The element type.    This is the element type index
2369                                        of the number_of_element array
2370                                        (see USERD_get_gold_part_build_info)
2372    (IN)  time_step   = The time step
2374    (IN)  imag_data   = TRUE if want imaginary value.
2375                        FALSE if want real value.
2377    (OUT) values      = scalar or vector component value(s)
2378                         values[0] = scalar or vector[0]
2379                         values[1] = vector[1]
2380                         values[2] = vector[2]
2383    Notes:
2384    -----
2385    * This routine is used in node querys over time (or element querys over
2386      time for Z_PER_ELEM variables).  If these operations are not critical
2387      to you, this can be a dummy routine.
2389    * The per_node or per_elem classification must be obtainable from the
2390      variable number (a var_classify array needs to be retained)
2392    * The time step given is for the proper variable timeset.
2395 --------------------------------------------------------------------
2396 USERD_set_filenames
2398    Description:
2399    -----------
2400    Receives the geometry and result filenames entered in the data
2401    dialog.  The user written code will have to store and use these
2402    as needed. The user written code must manage its own files!!
2404    Specification:
2405    -------------
2406    int USERD_set_filenames(char filename_1[],
2407                            char filename_2[],
2408                            char the_path[],
2409                            int swapbytes)
2411    Returns:
2412    -------
2413    Z_OK  if successful
2414    Z_ERR if not successful
2416    Arguments:
2417    ---------
2418    (IN) filename_1   = the filename entered into the geometry
2419                          field of the data dialog.
2421    (IN) filename_2   = the filename entered into the result
2422                          field of the data dialog.
2423                          (If the two_fields flag in USERD_get_name_of_reader
2424                           is FALSE, this will be null string)
2426    (IN) the_path     = the path info from the data dialog.
2427                        Note: filename_1 and filename_2 have already
2428                             had the path prepended to them.  This
2429                             is provided in case it is needed for
2430                             filenames contained in one of the files
2432    (IN) swapbytes    = TRUE if should swap bytes when reading data.
2433                      = FALSE normally.
2435    Notes:
2436    -----
2437    * Since you must manage everything from the input that is entered in
2438      these data dialog fields, this is an important routine!
2440    * It may be that you will need to have an executive type file that contains
2441      info and other filenames within it, like EnSight6's case file.
2444 --------------------------------------------------------------------
2445 USERD_set_server_number
2447    Description:
2448    -----------
2449    Receives the server number of how many total servers.
2451    Specification:
2452    -------------
2453    int USERD_set_server_number(int cur_serv,
2454                                int tot_servs)
2456    Returns:
2457    -------
2458    nothing
2460    Arguments:
2461    ---------
2462    (IN) cur_serv    = the current server.
2464    (IN) tot_servs   = the total number of servers.
2466    Notes:
2467    -----
2468    * Only useful if your user defined reader is being used with EnSight's
2469      Server-of-Server capability.  And even then, it may or may not be
2470      something that you can take advantage of.  If your data is already
2471      partitioned in some manner, such that you can access the proper
2472      portions using this information.
2474      For all non-SOS uses, this will simply be 1 of 1
2478 --------------------------------------------------------------------
2479 USERD_set_time_set_and_step
2481    Description:
2482    -----------
2483    Set the current time step in the desired timeset.  All functions that
2484    need time, and that do not explicitly pass it in, will use the timeset
2485    and step set by this routine, if needed.
2487    Specification:
2488    -------------
2489    void USERD_set_time_set_and_step(int timeset_number,
2490                                     int time_step)
2492    Returns:
2493    -------
2494    nothing
2496    Arguments:
2497    ---------
2498    (IN) timeset_number  = the timeset number (1 based).
2500                           For example:  If USERD_get_number_of_timesets
2501                                         returns 2, the valid timeset_number's
2502                                         would be 1 and 2.
2504    (IN) time_step       = The current time step to set
2506    Notes:
2507    -----
2508    * Current_time_step and Current_timeset would be set here
2512 --------------------------------------------------------------------
2513 USERD_stop_part_building
2515    Description:
2516    -----------
2517    This routine called when the part building dialog is closed.  It is
2518    provided in case you desire to release memory, etc. that was only needed
2519    during the part building process.
2521    Specification:
2522    -------------
2523    void USERD_stop_part_building( void )
2525    Returns:
2526    -------
2527    nothing
2529    Arguments:
2530    ---------
2531    none
2533    Notes:
2534    -----
2537 ---- end of doucment ----