Updated and Validated
[betaflight.git] / docs / Battery.md
blob4d2f385f6ef4e19a83d3835273e6d9b27ad64b90
1 # Battery Monitoring
3 Betaflight has a battery monitoring feature.  The voltage of the main battery can be measured by the system and used to trigger a low-battery warning [buzzer](Buzzer.md), on-board status LED flashing and LED strip patterns.
5 Low battery warnings can:
7 * Help ensure you have time to safely land the aircraft
8 * Help maintain the life and safety of your LiPo/LiFe batteries, which should not be discharged below manufacturer recommendations
10 Minimum and maximum cell voltages can be set, and these voltages are used to auto-detect the number of cells in the battery when it is first connected.
12 Per-cell monitoring is not supported, as we only use one ADC to read the battery voltage.
13   
14 ## Supported targets
16 All targets support battery voltage monitoring unless status.
18 ## Connections
20 When dealing with batteries **ALWAYS CHECK POLARITY!**
22 Measure expected voltages **first** and then connect to the flight controller.  Powering the flight controller with
23 incorrect voltage or reversed polarity will likely fry your flight controller. Ensure your flight controller
24 has a voltage divider capable of measuring your particular battery voltage.
26 ### Naze32
28 The Naze32 has an on-board battery divider circuit; just connect your main battery to the VBAT connector.
30 **CAUTION:**  When installing the connection from main battery to the VBAT connector, be sure to first disconnect the main battery from the frame/power distribution board.  Check the wiring very carefully before connecting battery again.  Incorrect connections can immediately and completely destroy the flight controller and connected peripherals (ESC, GPS, Receiver etc.).
32 ### CC3D
34 The CC3D has no battery divider.  To use voltage monitoring, you must create a divider that gives a 3.3v 
35 MAXIMUM output when the main battery is fully charged.  Connect the divider output to S5_IN/PA0/RC5.
37 Notes:
39 * S5_IN/PA0/RC5 is Pin 7 on the 8 pin connector, second to last pin, on the opposite end from the 
40   GND/+5/PPM signal input.
42 * When battery monitoring is enabled on the CC3D, RC5 can no-longer be used for PWM input.
44 ### Sparky
46 See the [Sparky board chapter](boards/Board%20-%20Sparky.md).
48 ## Configuration
50 Enable the `VBAT` feature.
52 Configure min/max cell voltages using the following CLI setting:
54 `vbat_scale` - Adjust this to match actual measured battery voltage to reported value (which may be displayed via the `status` command)
56 `vbat_max_cell_voltage` - Maximum voltage per cell, used for auto-detecting battery voltage in 0.01V units, i.e. 430 = 4.3V
58 `vbat_min_cell_voltage` - Minimum voltage per cell; this triggers battery-critical alarms, in 0.01V units, i.e. 330 = 3.3V
60 `vbat_warning_cell_voltage` - Warning voltage per cell; this triggers battery-warning alarms, in 0.01V units, i.e. 340 = 3.4V
62 `vbat_hysteresis` - Sets the hysteresis value for low-battery alarms, in 0.01V units, i.e. 10 = 0.10V
64 `vbat_duration_for_warning` - Period voltage has to sustain before the battery state is set to battery-warning, in 0.1 s, i.e. 60 = 6.0 seconds
66 `vbat_duration_for_critical` - Period voltage has to sustain before the battery state is set to battery-critical, in 0.1 s, i.e. 21 = 2.1 seconds
68 e.g.
69 ```
70 set vbat_scale = 110
71 set vbat_max_cell_voltage = 430
72 set vbat_min_cell_voltage = 330
73 set vbat_warning_cell_voltage = 340
74 set vbat_hysteresis = 1
75 set vbat_duration_for_warning = 60
76 set vbat_duration_for_critical = 20
77 ```
79 # Current Monitoring
81 Current monitoring (amperage) is supported by connecting a current meter to the appropriate current meter ADC input (see the documentation for your particular board).
83 When enabled, the following values calculated and used by the telemetry and OLED display subsystems:
84 * Amps
85 * mAh used
86 * Capacity remaining
88 ## Configuration
90 Enable current monitoring using the CLI command:
92 ```
93 feature CURRENT_METER
94 ```
96 Configure the current meter type using the `amperage_meter_type` settings here:
98 | Value   | Sensor Type            |
99 | ------- | ---------------------- | 
100 | NONE    | None                   |
101 | ADC     | ADC/hardware sensor    |
102 | VIRTUAL | Virtual sensor         |
104 Configure capacity using the `bat_capacity` setting, in mAh units.
106 If you're using an OSD that expects the multiwii current meter output value, then set `multiwii_amperage_meter_output` to `ON` (this multiplies amperage sent to MSP by 10 and truncates negative values)).
108 ### ADC Sensor
110 The current meter needs to be configured so the value read at the Analog to Digital Converter (ADC) input matches actual current draw.  Just like you need a voltmeter to correctly calibrate your voltage reading you also need an ammeter to calibrate the current sensor.
111 Unlike voltage sensing which is usually quite good from the factory, current sensing varies significantly from board to board and should be calibrated.
113 It is recommended to set `multiwii_amperage_meter_output` to `OFF` when calibrating ADC current sensor.
115 To measure the current a linear response device is used that converts the current traveling through it to a voltage to be read by the ADC on your flight controller.
116 The maximum voltage that the flight controller can read is 3.3V (3300 mV), this is usually the limiting factor on the maximum measurable current.
117 Most sensors use a shunt resistor to measure current however there are a few that use hall effect sensors.
119 The flight controller uses the following equation to convert the measured ADC voltage to a current.
121 Current(Amps) = ADC (mV) / amperage_meter_scale * 10 + amperage_meter_offset / 1000
123 Where the calibrations are:
125 | Setting                       | Description                                              |
126 | ----------------------------- | -------------------------------------------------------- | 
127 | `amperage_meter_scale`     | The scaling factor in mV/10A  |
128 | `amperage_meter_offset`    | The offset in mA |
130 This is in the mathematical form of y = x/m + b and with a few measurements along this line you can calibrate any combination of sensor and flight controller to a high accuracy.
132 #### Calibrate using an ammeter
134 **!!Important: Always take off your props before doing any testing!!**
136 To calibrate your flight controller with a current meter follow these steps.
138 1. Make a copy of [this google sheet](https://docs.google.com/spreadsheets/d/1lkL-X_FT9x2oqrwQEctDsEUhgdY19upNGc78M6FfJXY/). It will do all the math for you.
139 2. Hook your ammeter up in series with your drone and a charged battery. I suggest an XT60 extender with one lead cut. Now your ammeter will be displaying the true current draw of your system.
140 3. Connect to your flight controller through the configurator and check your current calibrations. Change them in the google sheet if needed.
141 4. Use the motor tab to increase the throttle and change the current draw of the drone to around 1 A on the ammeter (it does not matter if it is not exact).
142 5. Switch back to the power and battery tab and record current from the ammeter in the measured current column and the current reported by Betaflight in the flight controller current column (both in amps, to 2 decimal places).
143 6. Repeat this measurement (steps 4 and 5) 3 or more times at various currents from 0 to 5 Amps (make sure not to go over your ammeter rated current).
144 7. Once this is done make sure the results are linear on the graph and that the regression value is green. You can now update to the new calibration values and enjoy accurate battery usage information.
146 The same method can be applied to both hall effect sensors and shunt resistors. Shunt resistors will usually have an offset of less than +/- 1000 mA however hall effect sensors offsets will be much higher.
147 Note that while your calibration may be correct there is still a maximum current measure that you may exceed at maximum throttle, this will cause the current recorded by the flight controller to ceiling at this value even if the actual current is higher.
148 As a result the reported mAh used may be less than is actually used, always keep an eye on the battery voltage as well.
150 If you do not want to use google sheets then simply use some other tool that preforms a linear regression on the dataset. Multiply `amperage_meter_scale` used in testing by the slope and subtract the intercept in mA from  `amperage_meter_offset` to get the corrected calibration values.
152 ### Virtual Sensor
154 The virtual sensor uses the throttle position to calculate an estimated current value. This is useful when a real sensor is not available. The following settings adjust the virtual sensor calibration:
156 | Setting                       | Description                                              |
157 | ----------------------------- | -------------------------------------------------------- | 
158 | `amperage_meter_scale`     | The throttle scaling factor [centiamps, i.e. 1/100th A]  |
159 | `amperage_meter_offset`    | The current at zero throttle (while disarmed) [centiamps, i.e. 1/100th A] |
161 There are two simple methods to tune these parameters:  one uses a battery charger and another depends on actual current measurements.
163 #### Tuning Using Actual Current Measurements
164 If you know your craft's current draw (in Amperes) while disarmed (Imin) and at maximum throttle while armed (Imax), calculate the scaling factors as follows:
166 amperage_meter_scale = (Imax - Imin) * 100000 / (Tmax + (Tmax * Tmax / 50))
167 amperage_meter_offset = Imin * 100
169 Note: Tmax is maximum throttle offset (i.e. for `max_throttle` = 1850, Tmax = 1850 - 1000 = 850)
171 For example, assuming a maximum current of 34.2A, a minimum current of 2.8A, and a Tmax `max_throttle` = 1850:
173 amperage_meter_scale = (Imax - Imin) * 100000 / (Tmax + (Tmax * Tmax / 50))
174                     = (34.2 - 2.8) * 100000 / (850 + (850 * 850 / 50))
175                     = 205
176 amperage_meter_offset = Imin * 100 = 280
178 Measuring Imax requires a battery and an ESC that can both deliver and support max current for the duration of the measurement, so it's prone to big inaccuracies. Alternatively, current can be measured at a much lower throttle position and be taken into account in the calculations.
180 Following the previous example, if we measured an Ibench current of 6A at 30% of throttle (1255 in the motors tab because (0.3*(max_throttle-1000))+1000))
182 Tbench = Tmax * bench_throttle = 850 * 0.3 = 255
183 amperage_meter_scale = (Ibench - Imin) * 100000 / (Tbench + (Tbench * Tbench / 50))
184                     = (6 - 2.8) * 100000 / (255 + (255 * 255 / 50))
185                     = 205
186 amperage_meter_offset = Imin * 100 = 280
188 #### Tuning Using Battery Charger Measurement
189 If you cannot measure current draw directly, you can approximate it indirectly using your battery charger.  
190 However, note it may be difficult to adjust `amperage_meter_offset` using this method unless you can 
191 measure the actual current draw with the craft disarmed.
193 Note:
194 + This method depends on the accuracy of your battery charger; results may vary.
195 + If you add or replace equipment that changes the in-flight current draw (e.g. video transmitter, 
196   camera, gimbal, motors, prop pitch/sizes, ESCs, etc.), you should recalibrate.
198 The general method is:
200 1. Fully charge your flight battery
201 2. Fly your craft, using >50% of your battery pack capacity (estimated)
202 3. Note Cleanflight's reported mAh drawn
203 4. Fully charge your flight battery again, noting the amount of mAh recharged
204 5. Adjust `amperage_meter_scale` to according to the formula given below
205 6. Repeat and test
207 Given (a) the mAh recharged and (b) the cleanflight reported mAh drawn, calculate a new `amperage_meter_scale` value as follows:
209 amperage_meter_scale = old_amperage_meter_scale * (mAh_recharged / cleanflight_reported_mAh_drawn)
211 For example, assuming:
212 + An amount recharged of 1500 mAh
213 + A Cleanflight reported current drawn of 2000 mAh
214 + An existing `amperage_meter_scale` value of 400 (the default)
216 Then the updated `amperage_meter_scale` is:
218 amperage_meter_scale = old_amperage_meter_scale * (mAh_recharged / cleanflight_reported_mAh_drawn)
219                      = 400 * (1500 / 2000)
220                      = 300