1 title: Perle Mediaconverter: CM 1110 modules states
7 This check monitors the power state and fiber and copper LPRF and
8 link status of CM 1110 modules of Perle Meadiconverter devices
9 which support the PERLE-MCR-MGT MIB.
11 The check reports CRIT if no power to module. Otherwise it is OK.
13 The check is OK if the fiber and copper link states are UP. Otherwise
16 If the fiber LPRF state is OK the check is OK. If it is OFFLINE,
17 link fault, auto neg error or not applicable, the check goes CRIT.
19 If the copper LPRF state is OK the check is OK. Otherwise, in case of
20 remote fault, the check goes CRIT.
26 One service per module is created.