1 title: UCS C-Series Rack Server: Power supply unit (PSU)
2 agents: agent_ucs_bladecenter
3 catalog: hw/server/cisco
7 This check provides information about the power supply unit (PSU) of an UCS C-Series Rack Server.
8 This main check provides info about the PSU overall operability status. The sub check
9 ucs_c_rack_server_psu.voltage provides info about the PSU voltage status.
11 This check supports the following C-Series Rack Server models providing XML API 2.0
12 [Cisco UCS Rack-Mount Servers Cisco IMC XML API 2.0]:
14 - Cisco UCS C220 M5 Rack Server
16 - Cisco UCS C240 M5 Rack Server
18 - Cisco UCS C480 M5 Rack Server
20 - Cisco UCS C480 ML M5 Rack Server
22 - Cisco UCS C220 M4 Rack Server
24 - Cisco UCS C240 M4 Rack Server
26 - Cisco UCS C460 M4 Rack Server
28 This check does not support the C-Series Rack Server model "Cisco UCS C125 M5 Rack Server Node"
29 which is used as part of a "Cisco UCS C4200 Series Rack Server Chassis".
33 - {OK} in case the monitored operability status is one of:
36 - {WARN} in case the monitored operability status is one of:
37 powered-off, removed, identity-unestablishable, bios-post-timeout, disabled, malformed-fru, fabric-unsupported-conn, config, decomissioning, chassis-limit-exceeded, not-supported, discovery
39 - {CRIT} in case the monitored operability status is one of:
40 inoperable, degraded, power-problem, voltage-problem, thermal-problem, performance-problem, accessibility-problem, fabric-conn-problem, equipment-problem, peer-comm-problem
42 - {UNKNOWN} in ccase the monitored operability status is one of:
46 All PSUs of the rack server are found automatically.
49 One service for every power supply unit e.g. PSU 1.