1 Power allocator governor tunables
2 =================================
4 Trip points
5 -----------
7 The governor works optimally with the following two passive trip points:
9 1.  "switch on" trip point: temperature above which the governor
10     control loop starts operating.  This is the first passive trip
11     point of the thermal zone.
13 2.  "desired temperature" trip point: it should be higher than the
14     "switch on" trip point.  This the target temperature the governor
15     is controlling for.  This is the last passive trip point of the
16     thermal zone.
18 PID Controller
19 --------------
21 The power allocator governor implements a
22 Proportional-Integral-Derivative controller (PID controller) with
23 temperature as the control input and power as the controlled output:
25     P_max = k_p * e + k_i * err_integral + k_d * diff_err + sustainable_power
27 where
28     e = desired_temperature - current_temperature
29     err_integral is the sum of previous errors
30     diff_err = e - previous_error
32 It is similar to the one depicted below:
34                                       k_d
35                                        |
36 current_temp                           |
37      |                                 v
38      |                +----------+   +---+
39      |         +----->| diff_err |-->| X |------+
40      |         |      +----------+   +---+      |
41      |         |                                |      tdp        actor
42      |         |                      k_i       |       |  get_requested_power()
43      |         |                       |        |       |        |     |
44      |         |                       |        |       |        |     | ...
45      v         |                       v        v       v        v     v
46    +---+       |      +-------+      +---+    +---+   +---+   +----------+
47    | S |-------+----->| sum e |----->| X |--->| S |-->| S |-->|power     |
48    +---+       |      +-------+      +---+    +---+   +---+   |allocation|
49      ^         |                                ^             +----------+
50      |         |                                |                |     |
51      |         |        +---+                   |                |     |
52      |         +------->| X |-------------------+                v     v
53      |                  +---+                               granted performance
54 desired_temperature       ^
55                           |
56                           |
57                       k_po/k_pu
59 Sustainable power
60 -----------------
62 An estimate of the sustainable dissipatable power (in mW) should be
63 provided while registering the thermal zone.  This estimates the
64 sustained power that can be dissipated at the desired control
65 temperature.  This is the maximum sustained power for allocation at
66 the desired maximum temperature.  The actual sustained power can vary
67 for a number of reasons.  The closed loop controller will take care of
68 variations such as environmental conditions, and some factors related
69 to the speed-grade of the silicon.  `sustainable_power` is therefore
70 simply an estimate, and may be tuned to affect the aggressiveness of
71 the thermal ramp. For reference, the sustainable power of a 4" phone
72 is typically 2000mW, while on a 10" tablet is around 4500mW (may vary
73 depending on screen size).
75 If you are using device tree, do add it as a property of the
76 thermal-zone.  For example:
78         thermal-zones {
79                 soc_thermal {
80                         polling-delay = <1000>;
81                         polling-delay-passive = <100>;
82                         sustainable-power = <2500>;
83                         ...
85 Instead, if the thermal zone is registered from the platform code, pass a
86 `thermal_zone_params` that has a `sustainable_power`.  If no
87 `thermal_zone_params` were being passed, then something like below
88 will suffice:
90         static const struct thermal_zone_params tz_params = {
91                 .sustainable_power = 3500,
92         };
94 and then pass `tz_params` as the 5th parameter to
95 `thermal_zone_device_register()`
97 k_po and k_pu
98 -------------
100 The implementation of the PID controller in the power allocator
101 thermal governor allows the configuration of two proportional term
102 constants: `k_po` and `k_pu`.  `k_po` is the proportional term
103 constant during temperature overshoot periods (current temperature is
104 above "desired temperature" trip point).  Conversely, `k_pu` is the
105 proportional term constant during temperature undershoot periods
106 (current temperature below "desired temperature" trip point).
108 These controls are intended as the primary mechanism for configuring
109 the permitted thermal "ramp" of the system.  For instance, a lower
110 `k_pu` value will provide a slower ramp, at the cost of capping
111 available capacity at a low temperature.  On the other hand, a high
112 value of `k_pu` will result in the governor granting very high power
113 whilst temperature is low, and may lead to temperature overshooting.
115 The default value for `k_pu` is:
117     2 * sustainable_power / (desired_temperature - switch_on_temp)
119 This means that at `switch_on_temp` the output of the controller's
120 proportional term will be 2 * `sustainable_power`.  The default value
121 for `k_po` is:
123     sustainable_power / (desired_temperature - switch_on_temp)
125 Focusing on the proportional and feed forward values of the PID
126 controller equation we have:
128     P_max = k_p * e + sustainable_power
130 The proportional term is proportional to the difference between the
131 desired temperature and the current one.  When the current temperature
132 is the desired one, then the proportional component is zero and
133 `P_max` = `sustainable_power`.  That is, the system should operate in
134 thermal equilibrium under constant load.  `sustainable_power` is only
135 an estimate, which is the reason for closed-loop control such as this.
137 Expanding `k_pu` we get:
138     P_max = 2 * sustainable_power * (T_set - T) / (T_set - T_on) +
139         sustainable_power
141 where
142     T_set is the desired temperature
143     T is the current temperature
144     T_on is the switch on temperature
146 When the current temperature is the switch_on temperature, the above
147 formula becomes:
149     P_max = 2 * sustainable_power * (T_set - T_on) / (T_set - T_on) +
150         sustainable_power = 2 * sustainable_power + sustainable_power =
151         3 * sustainable_power
153 Therefore, the proportional term alone linearly decreases power from
154 3 * `sustainable_power` to `sustainable_power` as the temperature
155 rises from the switch on temperature to the desired temperature.
157 k_i and integral_cutoff
158 -----------------------
160 `k_i` configures the PID loop's integral term constant.  This term
161 allows the PID controller to compensate for long term drift and for
162 the quantized nature of the output control: cooling devices can't set
163 the exact power that the governor requests.  When the temperature
164 error is below `integral_cutoff`, errors are accumulated in the
165 integral term.  This term is then multiplied by `k_i` and the result
166 added to the output of the controller.  Typically `k_i` is set low (1
167 or 2) and `integral_cutoff` is 0.
172 `k_d` configures the PID loop's derivative term constant.  It's
173 recommended to leave it as the default: 0.
175 Cooling device power API
176 ========================
178 Cooling devices controlled by this governor must supply the additional
179 "power" API in their `cooling_device_ops`.  It consists on three ops:
181 1. int get_requested_power(struct thermal_cooling_device *cdev,
182         struct thermal_zone_device *tz, u32 *power);
183 @cdev: The `struct thermal_cooling_device` pointer
184 @tz: thermal zone in which we are currently operating
185 @power: pointer in which to store the calculated power
187 `get_requested_power()` calculates the power requested by the device
188 in milliwatts and stores it in @power .  It should return 0 on
189 success, -E* on failure.  This is currently used by the power
190 allocator governor to calculate how much power to give to each cooling
191 device.
193 2. int state2power(struct thermal_cooling_device *cdev, struct
194         thermal_zone_device *tz, unsigned long state, u32 *power);
195 @cdev: The `struct thermal_cooling_device` pointer
196 @tz: thermal zone in which we are currently operating
197 @state: A cooling device state
198 @power: pointer in which to store the equivalent power
200 Convert cooling device state @state into power consumption in
201 milliwatts and store it in @power.  It should return 0 on success, -E*
202 on failure.  This is currently used by thermal core to calculate the
203 maximum power that an actor can consume.
205 3. int power2state(struct thermal_cooling_device *cdev, u32 power,
206         unsigned long *state);
207 @cdev: The `struct thermal_cooling_device` pointer
208 @power: power in milliwatts
209 @state: pointer in which to store the resulting state
211 Calculate a cooling device state that would make the device consume at
212 most @power mW and store it in @state.  It should return 0 on success,
213 -E* on failure.  This is currently used by the thermal core to convert
214 a given power set by the power allocator governor to a state that the
215 cooling device can set.  It is a function because this conversion may
216 depend on external factors that may change so this function should the
217 best conversion given "current circumstances".
219 Cooling device weights
220 ----------------------
222 Weights are a mechanism to bias the allocation among cooling
223 devices.  They express the relative power efficiency of different
224 cooling devices.  Higher weight can be used to express higher power
225 efficiency.  Weighting is relative such that if each cooling device
226 has a weight of one they are considered equal.  This is particularly
227 useful in heterogeneous systems where two cooling devices may perform
228 the same kind of compute, but with different efficiency.  For example,
229 a system with two different types of processors.
231 If the thermal zone is registered using
232 `thermal_zone_device_register()` (i.e., platform code), then weights
233 are passed as part of the thermal zone's `thermal_bind_parameters`.
234 If the platform is registered using device tree, then they are passed
235 as the `contribution` property of each map in the `cooling-maps` node.
237 Limitations of the power allocator governor
238 ===========================================
240 The power allocator governor's PID controller works best if there is a
241 periodic tick.  If you have a driver that calls
242 `thermal_zone_device_update()` (or anything that ends up calling the
243 governor's `throttle()` function) repetitively, the governor response
244 won't be very good.  Note that this is not particular to this
245 governor, step-wise will also misbehave if you call its throttle()
246 faster than the normal thermal framework tick (due to interrupts for
247 example) as it will overreact.