1 /* Implementation of normal Python-accessible methods on the _dbus_bindings
2 * Connection type; separated out to keep the file size manageable.
4 * Copyright (C) 2006 Collabora Ltd. <http://www.collabora.co.uk/>
6 * Licensed under the Academic Free License version 2.1
8 * This library is free software; you can redistribute it and/or modify
9 * it under the terms of the GNU Lesser General Public License as published by
10 * the Free Software Foundation; either version 2.1 of the License, or
11 * (at your option) any later version.
13 * This library is distributed in the hope that it will be useful,
14 * but WITHOUT ANY WARRANTY; without even the implied warranty of
15 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
16 * GNU Lesser General Public License for more details.
18 * You should have received a copy of the GNU Lesser General Public License
19 * along with this library; if not, write to the Free Software
20 * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
24 #include "dbus_bindings-internal.h"
25 #include "conn-internal.h"
28 _object_path_unregister(DBusConnection
*conn
, void *user_data
)
30 PyGILState_STATE gil
= PyGILState_Ensure();
31 PyObject
*tuple
= NULL
;
32 Connection
*conn_obj
= NULL
;
35 conn_obj
= (Connection
*)DBusPyConnection_ExistingFromDBusConnection(conn
);
36 if (!conn_obj
) goto out
;
39 DBG("Connection at %p unregistering object path %s",
40 conn_obj
, PyString_AS_STRING((PyObject
*)user_data
));
41 tuple
= DBusPyConnection_GetObjectPathHandlers((PyObject
*)conn_obj
, (PyObject
*)user_data
);
43 if (tuple
== Py_None
) goto out
;
45 DBG("%s", "... yes we have handlers for that object path");
47 /* 0'th item is the unregisterer (if that's a word) */
48 callable
= PyTuple_GetItem(tuple
, 0);
49 if (callable
&& callable
!= Py_None
) {
50 DBG("%s", "... and we even have an unregisterer");
51 /* any return from the unregisterer is ignored */
52 Py_XDECREF(PyObject_CallFunctionObjArgs(callable
, conn_obj
, NULL
));
57 /* the user_data (a Python str) is no longer ref'd by the DBusConnection */
58 Py_XDECREF((PyObject
*)user_data
);
59 if (PyErr_Occurred()) {
62 PyGILState_Release(gil
);
65 static DBusHandlerResult
66 _object_path_message(DBusConnection
*conn
, DBusMessage
*message
,
69 DBusHandlerResult ret
;
70 PyGILState_STATE gil
= PyGILState_Ensure();
71 Connection
*conn_obj
= NULL
;
72 PyObject
*tuple
= NULL
;
74 PyObject
*callable
; /* borrowed */
76 dbus_message_ref(message
);
77 msg_obj
= DBusPyMessage_ConsumeDBusMessage(message
);
79 ret
= DBUS_HANDLER_RESULT_NEED_MEMORY
;
83 conn_obj
= (Connection
*)DBusPyConnection_ExistingFromDBusConnection(conn
);
85 ret
= DBUS_HANDLER_RESULT_NOT_YET_HANDLED
;
90 DBG("Connection at %p messaging object path %s",
91 conn_obj
, PyString_AS_STRING((PyObject
*)user_data
));
92 DBG_DUMP_MESSAGE(message
);
93 tuple
= DBusPyConnection_GetObjectPathHandlers((PyObject
*)conn_obj
, (PyObject
*)user_data
);
94 if (!tuple
|| tuple
== Py_None
) {
95 ret
= DBUS_HANDLER_RESULT_NOT_YET_HANDLED
;
99 DBG("%s", "... yes we have handlers for that object path");
101 /* 1st item (0-based) is the message callback */
102 callable
= PyTuple_GetItem(tuple
, 1);
104 DBG("%s", "... error getting message handler from tuple");
105 ret
= DBUS_HANDLER_RESULT_NOT_YET_HANDLED
;
107 else if (callable
== Py_None
) {
108 /* there was actually no handler after all */
109 DBG("%s", "... but those handlers don't do messages");
110 ret
= DBUS_HANDLER_RESULT_NOT_YET_HANDLED
;
113 DBG("%s", "... and we have a message handler for that object path");
114 ret
= DBusPyConnection_HandleMessage(conn_obj
, msg_obj
, callable
);
119 Py_XDECREF(conn_obj
);
121 if (PyErr_Occurred()) {
124 PyGILState_Release(gil
);
128 static const DBusObjectPathVTable _object_path_vtable
= {
129 _object_path_unregister
,
130 _object_path_message
,
133 static DBusHandlerResult
134 _filter_message(DBusConnection
*conn
, DBusMessage
*message
, void *user_data
)
136 DBusHandlerResult ret
;
137 PyGILState_STATE gil
= PyGILState_Ensure();
138 Connection
*conn_obj
= NULL
;
139 PyObject
*callable
= NULL
;
141 #ifndef DBUS_PYTHON_DISABLE_CHECKS
145 dbus_message_ref(message
);
146 msg_obj
= DBusPyMessage_ConsumeDBusMessage(message
);
148 DBG("%s", "OOM while trying to construct Message");
149 ret
= DBUS_HANDLER_RESULT_NEED_MEMORY
;
153 conn_obj
= (Connection
*)DBusPyConnection_ExistingFromDBusConnection(conn
);
155 DBG("%s", "failed to traverse DBusConnection -> Connection weakref");
156 ret
= DBUS_HANDLER_RESULT_NOT_YET_HANDLED
;
161 /* The user_data is a pointer to a Python object. To avoid
162 * cross-library reference cycles, the DBusConnection isn't allowed
163 * to reference it. However, as long as the Connection is still
164 * alive, its ->filters list owns a reference to the same Python
165 * object, so the object should also still be alive.
167 * To ensure that this works, be careful whenever manipulating the
168 * filters list! (always put things in the list *before* giving
169 * them to libdbus, etc.)
171 #ifdef DBUS_PYTHON_DISABLE_CHECKS
172 callable
= (PyObject
*)user_data
;
174 size
= PyList_GET_SIZE(conn_obj
->filters
);
175 for (i
= 0; i
< size
; i
++) {
176 callable
= PyList_GET_ITEM(conn_obj
->filters
, i
);
177 if (callable
== user_data
) {
186 DBG("... filter %p has vanished from ->filters, so not calling it",
188 ret
= DBUS_HANDLER_RESULT_NOT_YET_HANDLED
;
193 ret
= DBusPyConnection_HandleMessage(conn_obj
, msg_obj
, callable
);
196 Py_XDECREF(conn_obj
);
197 Py_XDECREF(callable
);
198 PyGILState_Release(gil
);
202 PyDoc_STRVAR(Connection__require_main_loop__doc__
,
203 "_require_main_loop()\n\n"
204 "Raise an exception if this Connection is not bound to any main loop -\n"
205 "in this state, asynchronous calls, receiving signals and exporting objects\n"
208 "`dbus.mainloop.NULL_MAIN_LOOP` is treated like a valid main loop - if you're\n"
209 "using that, you presumably know what you're doing.\n");
211 Connection__require_main_loop (Connection
*self
, PyObject
*args UNUSED
)
213 if (!self
->has_mainloop
) {
214 PyErr_SetString(PyExc_RuntimeError
,
215 "To make asynchronous calls, receive signals or "
216 "export objects, D-Bus connections must be attached "
217 "to a main loop by passing mainloop=... to the "
218 "constructor or calling "
219 "dbus.set_default_main_loop(...)");
225 PyDoc_STRVAR(Connection_close__doc__
,
227 "Close the connection.");
229 Connection_close (Connection
*self
, PyObject
*args UNUSED
)
232 /* Because the user explicitly asked to close the connection, we'll even
233 let them close shared connections. */
235 Py_BEGIN_ALLOW_THREADS
236 dbus_connection_close(self
->conn
);
242 PyDoc_STRVAR(Connection_get_is_connected__doc__
,
243 "get_is_connected() -> bool\n\n"
244 "Return true if this Connection is connected.\n");
246 Connection_get_is_connected (Connection
*self
, PyObject
*args UNUSED
)
251 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
252 Py_BEGIN_ALLOW_THREADS
253 ret
= dbus_connection_get_is_connected(self
->conn
);
255 return PyBool_FromLong(ret
);
258 PyDoc_STRVAR(Connection_get_is_authenticated__doc__
,
259 "get_is_authenticated() -> bool\n\n"
260 "Return true if this Connection was ever authenticated.\n");
262 Connection_get_is_authenticated (Connection
*self
, PyObject
*args UNUSED
)
267 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
268 Py_BEGIN_ALLOW_THREADS
269 ret
= dbus_connection_get_is_authenticated(self
->conn
);
271 return PyBool_FromLong(ret
);
274 PyDoc_STRVAR(Connection_set_exit_on_disconnect__doc__
,
275 "set_exit_on_disconnect(bool)\n\n"
276 "Set whether the C function ``_exit`` will be called when this Connection\n"
277 "becomes disconnected. This will cause the program to exit without calling\n"
278 "any cleanup code or exit handlers.\n"
280 "The default is for this feature to be disabled for Connections and enabled\n"
283 Connection_set_exit_on_disconnect (Connection
*self
, PyObject
*args
)
285 int exit_on_disconnect
;
288 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
289 if (!PyArg_ParseTuple(args
, "i:set_exit_on_disconnect",
290 &exit_on_disconnect
)) {
293 Py_BEGIN_ALLOW_THREADS
294 dbus_connection_set_exit_on_disconnect(self
->conn
,
295 exit_on_disconnect
? 1 : 0);
300 PyDoc_STRVAR(Connection_send_message__doc__
,
301 "send_message(msg) -> long\n\n"
302 "Queue the given message for sending, and return the message serial number.\n"
305 " `msg` : dbus.lowlevel.Message\n"
306 " The message to be sent.\n"
309 Connection_send_message(Connection
*self
, PyObject
*args
)
314 dbus_uint32_t serial
;
317 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
318 if (!PyArg_ParseTuple(args
, "O", &obj
)) return NULL
;
320 msg
= DBusPyMessage_BorrowDBusMessage(obj
);
321 if (!msg
) return NULL
;
323 Py_BEGIN_ALLOW_THREADS
324 ok
= dbus_connection_send(self
->conn
, msg
, &serial
);
328 return PyErr_NoMemory();
331 return PyLong_FromUnsignedLong(serial
);
334 /* The timeout is in seconds here, since that's conventional in Python. */
335 PyDoc_STRVAR(Connection_send_message_with_reply__doc__
,
336 "send_message_with_reply(msg, reply_handler, timeout_s=-1, "
337 "require_main_loop=False) -> dbus.lowlevel.PendingCall\n\n"
338 "Queue the message for sending; expect a reply via the returned PendingCall,\n"
339 "which can also be used to cancel the pending call.\n"
342 " `msg` : dbus.lowlevel.Message\n"
343 " The message to be sent\n"
344 " `reply_handler` : callable\n"
345 " Asynchronous reply handler: will be called with one positional\n"
346 " parameter, a Message instance representing the reply.\n"
347 " `timeout_s` : float\n"
348 " If the reply takes more than this many seconds, a timeout error\n"
349 " will be created locally and raised instead. If this timeout is\n"
350 " negative (default), a sane default (supplied by libdbus) is used.\n"
351 " `require_main_loop` : bool\n"
352 " If True, raise RuntimeError if this Connection does not have a main\n"
353 " loop configured. If False (default) and there is no main loop, you are\n"
354 " responsible for calling block() on the PendingCall.\n"
358 Connection_send_message_with_reply(Connection
*self
, PyObject
*args
, PyObject
*kw
)
361 double timeout_s
= -1.0;
363 PyObject
*obj
, *callable
;
365 DBusPendingCall
*pending
;
366 int require_main_loop
= 0;
367 static char *argnames
[] = {"msg", "reply_handler", "timeout_s",
368 "require_main_loop", NULL
};
371 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
372 if (!PyArg_ParseTupleAndKeywords(args
, kw
,
373 "OO|fi:send_message_with_reply",
375 &obj
, &callable
, &timeout_s
,
376 &require_main_loop
)) {
379 if (require_main_loop
&& !Connection__require_main_loop(self
, NULL
)) {
383 msg
= DBusPyMessage_BorrowDBusMessage(obj
);
384 if (!msg
) return NULL
;
390 if (timeout_s
> ((double)INT_MAX
) / 1000.0) {
391 PyErr_SetString(PyExc_ValueError
, "Timeout too long");
394 timeout_ms
= (int)(timeout_s
* 1000.0);
397 Py_BEGIN_ALLOW_THREADS
398 ok
= dbus_connection_send_with_reply(self
->conn
, msg
, &pending
,
403 return PyErr_NoMemory();
407 /* connection is disconnected (doesn't return FALSE!) */
408 PyErr_SetString (DBusPyException
, "Connection is disconnected - "
409 "unable to make method call");
413 return DBusPyPendingCall_ConsumeDBusPendingCall(pending
, callable
);
416 /* Again, the timeout is in seconds, since that's conventional in Python. */
417 PyDoc_STRVAR(Connection_send_message_with_reply_and_block__doc__
,
418 "send_message_with_reply_and_block(msg, timeout_s=-1)"
419 " -> dbus.lowlevel.Message\n\n"
420 "Send the message and block while waiting for a reply.\n"
422 "This does not re-enter the main loop, so it can lead to a deadlock, if\n"
423 "the called method tries to make a synchronous call to a method in this\n"
424 "application. As such, it's probably a bad idea.\n"
427 " `msg` : dbus.lowlevel.Message\n"
428 " The message to be sent\n"
429 " `timeout_s` : float\n"
430 " If the reply takes more than this many seconds, a timeout error\n"
431 " will be created locally and raised instead. If this timeout is\n"
432 " negative (default), a sane default (supplied by libdbus) is used.\n"
434 " A `dbus.lowlevel.Message` instance (probably a `dbus.lowlevel.MethodReturnMessage`) on success\n"
435 ":Raises dbus.DBusException:\n"
436 " On error (including if the reply arrives but is an\n"
441 Connection_send_message_with_reply_and_block(Connection
*self
, PyObject
*args
)
443 double timeout_s
= -1.0;
446 DBusMessage
*msg
, *reply
;
450 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
451 if (!PyArg_ParseTuple(args
, "O|f:send_message_with_reply_and_block", &obj
,
456 msg
= DBusPyMessage_BorrowDBusMessage(obj
);
457 if (!msg
) return NULL
;
463 if (timeout_s
> ((double)INT_MAX
) / 1000.0) {
464 PyErr_SetString(PyExc_ValueError
, "Timeout too long");
467 timeout_ms
= (int)(timeout_s
* 1000.0);
470 dbus_error_init(&error
);
471 Py_BEGIN_ALLOW_THREADS
472 reply
= dbus_connection_send_with_reply_and_block(self
->conn
, msg
,
477 return DBusPyException_ConsumeError(&error
);
479 return DBusPyMessage_ConsumeDBusMessage(reply
);
482 PyDoc_STRVAR(Connection_flush__doc__
,
484 "Block until the outgoing message queue is empty.\n");
486 Connection_flush (Connection
*self
, PyObject
*args UNUSED
)
489 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
490 Py_BEGIN_ALLOW_THREADS
491 dbus_connection_flush (self
->conn
);
497 * dbus_connection_preallocate_send
498 * dbus_connection_free_preallocated_send
499 * dbus_connection_send_preallocated
500 * dbus_connection_borrow_message
501 * dbus_connection_return_message
502 * dbus_connection_steal_borrowed_message
503 * dbus_connection_pop_message
506 /* Non-main-loop handling not yet implemented: */
507 /* dbus_connection_read_write_dispatch */
508 /* dbus_connection_read_write */
510 /* Main loop handling not yet implemented: */
511 /* dbus_connection_get_dispatch_status */
512 /* dbus_connection_dispatch */
513 /* dbus_connection_set_watch_functions */
514 /* dbus_connection_set_timeout_functions */
515 /* dbus_connection_set_wakeup_main_function */
516 /* dbus_connection_set_dispatch_status_function */
518 /* Normally in Python this would be called fileno(), but I don't want to
519 * encourage people to select() on it */
520 PyDoc_STRVAR(Connection_get_unix_fd__doc__
,
521 "get_unix_fd() -> int or None\n\n"
522 "Get the connection's UNIX file descriptor, if any.\n\n"
523 "This can be used for SELinux access control checks with ``getpeercon()``\n"
524 "for example. **Do not** read or write to the file descriptor, or try to\n"
525 "``select()`` on it.\n");
527 Connection_get_unix_fd (Connection
*self
, PyObject
*unused UNUSED
)
533 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
534 Py_BEGIN_ALLOW_THREADS
535 ok
= dbus_connection_get_unix_fd (self
->conn
, &fd
);
537 if (!ok
) Py_RETURN_NONE
;
538 return PyInt_FromLong(fd
);
541 PyDoc_STRVAR(Connection_get_peer_unix_user__doc__
,
542 "get_peer_unix_user() -> long or None\n\n"
543 "Get the UNIX user ID at the other end of the connection, if it has been\n"
544 "authenticated. Return None if this is a non-UNIX platform or the\n"
545 "connection has not been authenticated.\n");
547 Connection_get_peer_unix_user (Connection
*self
, PyObject
*unused UNUSED
)
553 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
554 Py_BEGIN_ALLOW_THREADS
555 ok
= dbus_connection_get_unix_user (self
->conn
, &uid
);
557 if (!ok
) Py_RETURN_NONE
;
558 return PyLong_FromUnsignedLong (uid
);
561 PyDoc_STRVAR(Connection_get_peer_unix_process_id__doc__
,
562 "get_peer_unix_process_id() -> long or None\n\n"
563 "Get the UNIX process ID at the other end of the connection, if it has been\n"
564 "authenticated. Return None if this is a non-UNIX platform or the\n"
565 "connection has not been authenticated.\n");
567 Connection_get_peer_unix_process_id (Connection
*self
, PyObject
*unused UNUSED
)
573 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
574 Py_BEGIN_ALLOW_THREADS
575 ok
= dbus_connection_get_unix_process_id (self
->conn
, &pid
);
577 if (!ok
) Py_RETURN_NONE
;
578 return PyLong_FromUnsignedLong (pid
);
581 /* TODO: wrap dbus_connection_set_unix_user_function Pythonically */
583 PyDoc_STRVAR(Connection_add_message_filter__doc__
,
584 "add_message_filter(callable)\n\n"
585 "Add the given message filter to the internal list.\n\n"
586 "Filters are handlers that are run on all incoming messages, prior to the\n"
587 "objects registered to handle object paths.\n"
589 "Filters are run in the order that they were added. The same handler can\n"
590 "be added as a filter more than once, in which case it will be run more\n"
591 "than once. Filters added during a filter callback won't be run on the\n"
592 "message being processed.\n"
595 Connection_add_message_filter(Connection
*self
, PyObject
*callable
)
600 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
601 /* The callable must be referenced by ->filters *before* it is
602 * given to libdbus, which does not own a reference to it.
604 if (PyList_Append(self
->filters
, callable
) < 0) {
608 Py_BEGIN_ALLOW_THREADS
609 ok
= dbus_connection_add_filter(self
->conn
, _filter_message
, callable
,
614 Py_XDECREF(PyObject_CallMethod(self
->filters
, "remove", "(O)",
622 PyDoc_STRVAR(Connection_remove_message_filter__doc__
,
623 "remove_message_filter(callable)\n\n"
624 "Remove the given message filter (see `add_message_filter` for details).\n"
626 ":Raises LookupError:\n"
627 " The given callable is not among the registered filters\n");
629 Connection_remove_message_filter(Connection
*self
, PyObject
*callable
)
634 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
635 /* It's safe to do this before removing it from libdbus, because
636 * the presence of callable in our arguments means we have a ref
638 obj
= PyObject_CallMethod(self
->filters
, "remove", "(O)", callable
);
639 if (!obj
) return NULL
;
642 Py_BEGIN_ALLOW_THREADS
643 dbus_connection_remove_filter(self
->conn
, _filter_message
, callable
);
649 PyDoc_STRVAR(Connection__register_object_path__doc__
,
650 "register_object_path(path, on_message, on_unregister=None, fallback=False)\n"
652 "Register a callback to be called when messages arrive at the given\n"
653 "object-path. Used to export objects' methods on the bus in a low-level\n"
654 "way. For the high-level interface to this functionality (usually\n"
655 "recommended) see the `dbus.service.Object` base class.\n"
659 " Object path to be acted on\n"
660 " `on_message` : callable\n"
661 " Called when a message arrives at the given object-path, with\n"
662 " two positional parameters: the first is this Connection,\n"
663 " the second is the incoming `dbus.lowlevel.Message`.\n"
664 " `on_unregister` : callable or None\n"
665 " If not None, called when the callback is unregistered.\n"
666 " `fallback` : bool\n"
667 " If True (the default is False), when a message arrives for a\n"
668 " 'subdirectory' of the given path and there is no more specific\n"
669 " handler, use this handler. Normally this handler is only run if\n"
670 " the paths match exactly.\n"
673 Connection__register_object_path(Connection
*self
, PyObject
*args
,
678 PyObject
*callbacks
, *path
, *tuple
, *on_message
, *on_unregister
= Py_None
;
679 static char *argnames
[] = {"path", "on_message", "on_unregister",
683 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
684 if (!Connection__require_main_loop(self
, NULL
)) {
687 if (!PyArg_ParseTupleAndKeywords(args
, kwargs
,
688 "OO|Oi:_register_object_path",
691 &on_message
, &on_unregister
,
692 &fallback
)) return NULL
;
694 /* Take a reference to path, which we give away to libdbus in a moment.
696 Also, path needs to be a string (not a subclass which could do something
697 mad) to preserve the desirable property that the DBusConnection can
698 never strongly reference the Connection, even indirectly.
700 if (PyString_CheckExact(path
)) {
703 else if (PyUnicode_Check(path
)) {
704 path
= PyUnicode_AsUTF8String(path
);
705 if (!path
) return NULL
;
707 else if (PyString_Check(path
)) {
708 path
= PyString_FromString(PyString_AS_STRING(path
));
709 if (!path
) return NULL
;
712 PyErr_SetString(PyExc_TypeError
, "path must be a str or unicode object");
716 if (!dbus_py_validate_object_path(PyString_AS_STRING(path
))) {
721 tuple
= Py_BuildValue("(OO)", on_unregister
, on_message
);
727 /* Guard against registering a handler that already exists. */
728 callbacks
= PyDict_GetItem(self
->object_paths
, path
);
729 if (callbacks
&& callbacks
!= Py_None
) {
730 PyErr_Format(PyExc_KeyError
, "Can't register the object-path "
731 "handler for '%s': there is already a handler",
732 PyString_AS_STRING(path
));
738 /* Pre-allocate a slot in the dictionary, so we know we'll be able
739 * to replace it with the callbacks without OOM.
740 * This ensures we can keep libdbus' opinion of whether those
741 * paths are handled in sync with our own. */
742 if (PyDict_SetItem(self
->object_paths
, path
, Py_None
) < 0) {
748 Py_BEGIN_ALLOW_THREADS
750 ok
= dbus_connection_register_fallback(self
->conn
,
751 PyString_AS_STRING(path
),
752 &_object_path_vtable
,
756 ok
= dbus_connection_register_object_path(self
->conn
,
757 PyString_AS_STRING(path
),
758 &_object_path_vtable
,
764 if (PyDict_SetItem(self
->object_paths
, path
, tuple
) < 0) {
765 /* That shouldn't have happened, we already allocated enough
766 memory for it. Oh well, try to undo the registration to keep
767 things in sync. If this fails too, we've leaked a bit of
768 memory in libdbus, but tbh we should never get here anyway. */
769 Py_BEGIN_ALLOW_THREADS
770 ok
= dbus_connection_unregister_object_path(self
->conn
,
771 PyString_AS_STRING(path
));
775 /* don't DECREF path: libdbus owns a ref now */
780 /* Oops, OOM. Tidy up, if we can, ignoring any error. */
781 PyDict_DelItem(self
->object_paths
, path
);
790 PyDoc_STRVAR(Connection__unregister_object_path__doc__
,
791 "unregister_object_path(path)\n\n"
792 "Remove a previously registered handler for the given object path.\n"
796 " The object path whose handler is to be removed\n"
797 ":Raises KeyError: if there is no handler registered for exactly that\n"
801 Connection__unregister_object_path(Connection
*self
, PyObject
*args
,
807 static char *argnames
[] = {"path", NULL
};
810 DBUS_PY_RAISE_VIA_NULL_IF_FAIL(self
->conn
);
811 if (!PyArg_ParseTupleAndKeywords(args
, kwargs
,
812 "O:_unregister_object_path",
813 argnames
, &path
)) return NULL
;
815 /* Take a ref to the path. Same comments as for _register_object_path. */
816 if (PyString_CheckExact(path
)) {
819 else if (PyUnicode_Check(path
)) {
820 path
= PyUnicode_AsUTF8String(path
);
821 if (!path
) return NULL
;
823 else if (PyString_Check(path
)) {
824 path
= PyString_FromString(PyString_AS_STRING(path
));
825 if (!path
) return NULL
;
828 PyErr_SetString(PyExc_TypeError
, "path must be a str or unicode object");
832 /* Guard against unregistering a handler that doesn't, in fact, exist,
833 or whose unregistration is already in progress. */
834 callbacks
= PyDict_GetItem(self
->object_paths
, path
);
835 if (!callbacks
|| callbacks
== Py_None
) {
836 PyErr_Format(PyExc_KeyError
, "Can't unregister the object-path "
837 "handler for '%s': there is no such handler",
838 PyString_AS_STRING(path
));
843 /* Hang on to a reference to the callbacks for the moment. */
844 Py_INCREF(callbacks
);
846 /* Get rid of the object-path while we still have the GIL, to
847 guard against unregistering twice from different threads (which
848 causes undefined behaviour in libdbus).
850 Because deletion would make it possible for the re-insertion below
851 to fail, we instead set the handler to None as a placeholder.
853 if (PyDict_SetItem(self
->object_paths
, path
, Py_None
) < 0) {
854 /* If that failed, there's no need to be paranoid as below - the
855 callbacks are still set, so we failed, but at least everything
857 Py_DECREF(callbacks
);
863 This is something of a critical section - the dict of object-paths
864 and libdbus' internal structures are out of sync for a bit. We have
865 to be able to cope with that.
867 It's really annoying that dbus_connection_unregister_object_path
868 can fail, *and* has undefined behaviour if the object path has
869 already been unregistered. Either/or would be fine.
872 Py_BEGIN_ALLOW_THREADS
873 ok
= dbus_connection_unregister_object_path(self
->conn
,
874 PyString_AS_STRING(path
));
878 Py_DECREF(callbacks
);
879 PyDict_DelItem(self
->object_paths
, path
);
880 /* END PARANOIA on successful code path */
881 /* The above can't fail unless by some strange trickery the key is no
882 longer present. Ignore any errors. */
888 /* Oops, OOM. Put the callbacks back in the dict so
889 * we'll have another go if/when the user frees some memory
890 * and tries calling this method again. */
891 PyDict_SetItem(self
->object_paths
, path
, callbacks
);
892 /* END PARANOIA on failing code path */
893 /* If the SetItem failed, there's nothing we can do about it - but
894 since we know it's an existing entry, it shouldn't be able to fail
897 Py_DECREF(callbacks
);
898 return PyErr_NoMemory();
902 /* dbus_connection_get_object_path_data - not useful to Python,
903 * the object path data is just a PyString containing the path */
904 /* dbus_connection_list_registered could be useful, though */
906 /* dbus_connection_set_change_sigpipe - sets global state */
908 /* Maxima. Does Python code ever need to manipulate these?
909 * OTOH they're easy to wrap */
910 /* dbus_connection_set_max_message_size */
911 /* dbus_connection_get_max_message_size */
912 /* dbus_connection_set_max_received_size */
913 /* dbus_connection_get_max_received_size */
915 /* dbus_connection_get_outgoing_size - almost certainly unneeded */
917 PyDoc_STRVAR(new_for_bus__doc__
,
918 "Connection._new_for_bus([address: str or int]) -> Connection\n"
920 "If the address is an int it must be one of the constants BUS_SESSION,\n"
921 "BUS_SYSTEM, BUS_STARTER; if a string, it must be a D-Bus address.\n"
922 "The default is BUS_SESSION.\n"
925 PyDoc_STRVAR(get_unique_name__doc__
,
926 "get_unique_name() -> str\n\n"
927 "Return this application's unique name on this bus.\n"
929 ":Raises DBusException: if the connection has no unique name yet\n"
930 " (for Bus objects this can't happen, for peer-to-peer connections\n"
931 " this means you haven't called `set_unique_name`)\n");
933 PyDoc_STRVAR(set_unique_name__doc__
,
934 "set_unique_name(str)\n\n"
935 "Set this application's unique name on this bus. Raise ValueError if it has\n"
936 "already been set.\n");
938 struct PyMethodDef DBusPyConnection_tp_methods
[] = {
939 #define ENTRY(name, flags) {#name, (PyCFunction)Connection_##name, flags, Connection_##name##__doc__}
940 ENTRY(_require_main_loop
, METH_NOARGS
),
941 ENTRY(close
, METH_NOARGS
),
942 ENTRY(flush
, METH_NOARGS
),
943 ENTRY(get_is_connected
, METH_NOARGS
),
944 ENTRY(get_is_authenticated
, METH_NOARGS
),
945 ENTRY(set_exit_on_disconnect
, METH_VARARGS
),
946 ENTRY(get_unix_fd
, METH_NOARGS
),
947 ENTRY(get_peer_unix_user
, METH_NOARGS
),
948 ENTRY(get_peer_unix_process_id
, METH_NOARGS
),
949 ENTRY(add_message_filter
, METH_O
),
950 ENTRY(_register_object_path
, METH_VARARGS
|METH_KEYWORDS
),
951 ENTRY(remove_message_filter
, METH_O
),
952 ENTRY(send_message
, METH_VARARGS
),
953 ENTRY(send_message_with_reply
, METH_VARARGS
|METH_KEYWORDS
),
954 ENTRY(send_message_with_reply_and_block
, METH_VARARGS
),
955 ENTRY(_unregister_object_path
, METH_VARARGS
|METH_KEYWORDS
),
956 {"_new_for_bus", (PyCFunction
)DBusPyConnection_NewForBus
,
957 METH_CLASS
|METH_VARARGS
|METH_KEYWORDS
,
959 {"get_unique_name", (PyCFunction
)DBusPyConnection_GetUniqueName
,
961 get_unique_name__doc__
},
962 {"set_unique_name", (PyCFunction
)DBusPyConnection_SetUniqueName
,
964 set_unique_name__doc__
},
969 /* vim:set ft=c cino< sw=4 sts=4 et: */