1 What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory
4 Contact: Jacopo Mondi <jacopo@jmondi.org>
6 Writing '1' triggers a 'Factory' calibration cycle.
8 What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background
11 Contact: Jacopo Mondi <jacopo@jmondi.org>
13 Writing '1' triggers a 'Background' calibration cycle.
15 What: /sys/bus/iio/devices/iio:deviceX/error_status_available
18 Contact: Jacopo Mondi <jacopo@jmondi.org>
20 Reading returns the list of possible chip error status.
21 Available options are:
22 - 'error_fatal': Analog front-end initialization error
23 - 'error_i2c': Read/write to non-existing register
24 - 'error_algorithm': Corrupted parameters
25 - 'error_calibration': Calibration has failed
26 - 'error_self_diagnostic': Internal interface failure
27 - 'error_out_of_range': Measured concentration out of scale
28 - 'error_memory': Error during memory operations
29 - 'error_no_measurement': Cleared at first measurement
30 - 'error_low_voltage': Sensor regulated voltage too low
31 - 'error_measurement_timeout': Unable to complete measurement
33 What: /sys/bus/iio/devices/iio:deviceX/error_status
36 Contact: Jacopo Mondi <jacopo@jmondi.org>
38 Reading returns the current chip error status.