1 What: /sys/bus/iio/devices/triggerX/master_mode_available
3 Contact: benjamin.gaignard@st.com
5 Reading returns the list possible master modes which are:
9 The UG bit from the TIMx_EGR register is
10 used as trigger output (TRGO).
12 The Counter Enable signal CNT_EN is used
15 The update event is selected as trigger output.
16 For instance a master timer can then be used
17 as a prescaler for a slave timer.
19 The trigger output send a positive pulse
20 when the CC1IF flag is to be set.
22 OC1REF signal is used as trigger output.
24 OC2REF signal is used as trigger output.
26 OC3REF signal is used as trigger output.
28 OC4REF signal is used as trigger output.
30 Additional modes (on TRGO2 only):
33 OC5REF signal is used as trigger output.
35 OC6REF signal is used as trigger output.
36 - "compare_pulse_OC4REF":
37 OC4REF rising or falling edges generate pulses.
38 - "compare_pulse_OC6REF":
39 OC6REF rising or falling edges generate pulses.
40 - "compare_pulse_OC4REF_r_or_OC6REF_r":
41 OC4REF or OC6REF rising edges generate pulses.
42 - "compare_pulse_OC4REF_r_or_OC6REF_f":
43 OC4REF rising or OC6REF falling edges generate
45 - "compare_pulse_OC5REF_r_or_OC6REF_r":
46 OC5REF or OC6REF rising edges generate pulses.
47 - "compare_pulse_OC5REF_r_or_OC6REF_f":
48 OC5REF rising or OC6REF falling edges generate
53 +-----------+ +-------------+ +---------+
54 | Prescaler +-> | Counter | +-> | Master | TRGO(2)
55 +-----------+ +--+--------+-+ |-> | Control +-->
57 +--v--------+-+ OCxREF || +---------+
58 | Chx compare +----------> | Output | ChX
59 +-----------+-+ | | Control +-->
62 +-----------v-+ OC6REF | .
63 | Ch6 compare +---------+>
66 Example with: "compare_pulse_OC4REF_r_or_OC6REF_r"::
86 What: /sys/bus/iio/devices/triggerX/master_mode
88 Contact: benjamin.gaignard@st.com
90 Reading returns the current master modes.
91 Writing set the master mode
93 What: /sys/bus/iio/devices/iio:deviceX/in_count0_preset
95 Contact: benjamin.gaignard@st.com
97 Reading returns the current preset value.
98 Writing sets the preset value.
99 When counting up the counter starts from 0 and fires an
100 event when reach preset value.
101 When counting down the counter start from preset value
102 and fire event when reach 0.
104 What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
106 Contact: benjamin.gaignard@st.com
108 Reading returns the list possible enable modes.
110 What: /sys/bus/iio/devices/iio:deviceX/in_count0_enable_mode
112 Contact: benjamin.gaignard@st.com
114 Configure the device counter enable modes, in all case
115 counting direction is set by in_count0_count_direction
116 attribute and the counter is clocked by the internal clock.
119 Counter is always ON.
122 Counting is enabled when connected trigger signal
123 level is high else counting is disabled.
126 Counting is enabled on rising edge of the connected
127 trigger, and remains enabled for the duration of this
130 What: /sys/bus/iio/devices/iio:deviceX/in_count_trigger_mode_available
132 Contact: benjamin.gaignard@st.com
134 Reading returns the list possible trigger modes.
136 What: /sys/bus/iio/devices/iio:deviceX/in_count0_trigger_mode
138 Contact: benjamin.gaignard@st.com
140 Configure the device counter trigger mode
141 counting direction is set by in_count0_count_direction
142 attribute and the counter is clocked by the connected trigger