[linux-2.6/linux-mips.git] / drivers / hwmon / pmbus / Kconfig
blobc9237b9dcff2a29b7d289268597f8095981a460e
2 # PMBus chip drivers configuration
5 menuconfig PMBUS
6         tristate "PMBus support"
7         depends on I2C && EXPERIMENTAL
8         default n
9         help
10           Say yes here if you want to enable PMBus support.
12           This driver can also be built as a module. If so, the module will
13           be called pmbus_core.
15 if PMBUS
17 config SENSORS_PMBUS
18         tristate "Generic PMBus devices"
19         default y
20         help
21           If you say yes here you get hardware monitoring support for generic
22           PMBus devices, including but not limited to ADP4000, BMR450, BMR451,
23           BMR453, BMR454, LTC2978, NCP4200, and NCP4208.
25           This driver can also be built as a module. If so, the module will
26           be called pmbus.
28 config SENSORS_ADM1275
29         tristate "Analog Devices ADM1275"
30         default n
31         help
32           If you say yes here you get hardware monitoring support for Analog
33           Devices ADM1275 Hot-Swap Controller and Digital Power Monitor.
35           This driver can also be built as a module. If so, the module will
36           be called adm1275.
38 config SENSORS_LM25066
39         tristate "National Semiconductor LM25066 and compatibles"
40         default n
41         help
42           If you say yes here you get hardware monitoring support for National
43           Semiconductor LM25066, LM5064, and LM5066.
45           This driver can also be built as a module. If so, the module will
46           be called lm25066.
48 config SENSORS_MAX16064
49         tristate "Maxim MAX16064"
50         default n
51         help
52           If you say yes here you get hardware monitoring support for Maxim
53           MAX16064.
55           This driver can also be built as a module. If so, the module will
56           be called max16064.
58 config SENSORS_MAX34440
59         tristate "Maxim MAX34440/MAX34441"
60         default n
61         help
62           If you say yes here you get hardware monitoring support for Maxim
63           MAX34440 and MAX34441.
65           This driver can also be built as a module. If so, the module will
66           be called max34440.
68 config SENSORS_MAX8688
69         tristate "Maxim MAX8688"
70         default n
71         help
72           If you say yes here you get hardware monitoring support for Maxim
73           MAX8688.
75           This driver can also be built as a module. If so, the module will
76           be called max8688.
78 config SENSORS_UCD9000
79         tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
80         default n
81         help
82           If you say yes here you get hardware monitoring support for TI
83           UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
84           Controllers.
86           This driver can also be built as a module. If so, the module will
87           be called ucd9000.
89 config SENSORS_UCD9200
90         tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
91         default n
92         help
93           If you say yes here you get hardware monitoring support for TI
94           UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
95           Digital PWM System Controllers.
97           This driver can also be built as a module. If so, the module will
98           be called ucd9200.
100 endif # PMBUS