include: replace linux/module.h with "struct module" wherever possible
[linux-2.6/next.git] / include / linux / virtio_blk.h
blobe0edb40ca7aaca3ffeeb9261fa017eedd6548291
1 #ifndef _LINUX_VIRTIO_BLK_H
2 #define _LINUX_VIRTIO_BLK_H
3 /* This header is BSD licensed so anyone can use the definitions to implement
4 * compatible drivers/servers.
6 * Redistribution and use in source and binary forms, with or without
7 * modification, are permitted provided that the following conditions
8 * are met:
9 * 1. Redistributions of source code must retain the above copyright
10 * notice, this list of conditions and the following disclaimer.
11 * 2. Redistributions in binary form must reproduce the above copyright
12 * notice, this list of conditions and the following disclaimer in the
13 * documentation and/or other materials provided with the distribution.
14 * 3. Neither the name of IBM nor the names of its contributors
15 * may be used to endorse or promote products derived from this software
16 * without specific prior written permission.
17 * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ``AS IS'' AND
18 * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
19 * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
20 * ARE DISCLAIMED. IN NO EVENT SHALL IBM OR CONTRIBUTORS BE LIABLE
21 * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
22 * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
23 * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
24 * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
25 * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
26 * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
27 * SUCH DAMAGE. */
28 #include <linux/types.h>
29 #include <linux/virtio_ids.h>
30 #include <linux/virtio_config.h>
32 /* Feature bits */
33 #define VIRTIO_BLK_F_BARRIER 0 /* Does host support barriers? */
34 #define VIRTIO_BLK_F_SIZE_MAX 1 /* Indicates maximum segment size */
35 #define VIRTIO_BLK_F_SEG_MAX 2 /* Indicates maximum # of segments */
36 #define VIRTIO_BLK_F_GEOMETRY 4 /* Legacy geometry available */
37 #define VIRTIO_BLK_F_RO 5 /* Disk is read-only */
38 #define VIRTIO_BLK_F_BLK_SIZE 6 /* Block size of disk is available*/
39 #define VIRTIO_BLK_F_SCSI 7 /* Supports scsi command passthru */
40 #define VIRTIO_BLK_F_FLUSH 9 /* Cache flush command support */
41 #define VIRTIO_BLK_F_TOPOLOGY 10 /* Topology information is available */
43 #define VIRTIO_BLK_ID_BYTES 20 /* ID string length */
45 struct virtio_blk_config {
46 /* The capacity (in 512-byte sectors). */
47 __u64 capacity;
48 /* The maximum segment size (if VIRTIO_BLK_F_SIZE_MAX) */
49 __u32 size_max;
50 /* The maximum number of segments (if VIRTIO_BLK_F_SEG_MAX) */
51 __u32 seg_max;
52 /* geometry the device (if VIRTIO_BLK_F_GEOMETRY) */
53 struct virtio_blk_geometry {
54 __u16 cylinders;
55 __u8 heads;
56 __u8 sectors;
57 } geometry;
59 /* block size of device (if VIRTIO_BLK_F_BLK_SIZE) */
60 __u32 blk_size;
62 /* the next 4 entries are guarded by VIRTIO_BLK_F_TOPOLOGY */
63 /* exponent for physical block per logical block. */
64 __u8 physical_block_exp;
65 /* alignment offset in logical blocks. */
66 __u8 alignment_offset;
67 /* minimum I/O size without performance penalty in logical blocks. */
68 __u16 min_io_size;
69 /* optimal sustained I/O size in logical blocks. */
70 __u32 opt_io_size;
72 } __attribute__((packed));
75 * Command types
77 * Usage is a bit tricky as some bits are used as flags and some are not.
79 * Rules:
80 * VIRTIO_BLK_T_OUT may be combined with VIRTIO_BLK_T_SCSI_CMD or
81 * VIRTIO_BLK_T_BARRIER. VIRTIO_BLK_T_FLUSH is a command of its own
82 * and may not be combined with any of the other flags.
85 /* These two define direction. */
86 #define VIRTIO_BLK_T_IN 0
87 #define VIRTIO_BLK_T_OUT 1
89 /* This bit says it's a scsi command, not an actual read or write. */
90 #define VIRTIO_BLK_T_SCSI_CMD 2
92 /* Cache flush command */
93 #define VIRTIO_BLK_T_FLUSH 4
95 /* Get device ID command */
96 #define VIRTIO_BLK_T_GET_ID 8
98 /* Barrier before this op. */
99 #define VIRTIO_BLK_T_BARRIER 0x80000000
101 /* This is the first element of the read scatter-gather list. */
102 struct virtio_blk_outhdr {
103 /* VIRTIO_BLK_T* */
104 __u32 type;
105 /* io priority. */
106 __u32 ioprio;
107 /* Sector (ie. 512 byte offset) */
108 __u64 sector;
111 struct virtio_scsi_inhdr {
112 __u32 errors;
113 __u32 data_len;
114 __u32 sense_len;
115 __u32 residual;
118 /* And this is the final byte of the write scatter-gather list. */
119 #define VIRTIO_BLK_S_OK 0
120 #define VIRTIO_BLK_S_IOERR 1
121 #define VIRTIO_BLK_S_UNSUPP 2
122 #endif /* _LINUX_VIRTIO_BLK_H */