Add linux-next specific files for 20110817
[linux-2.6/next.git] / Documentation / filesystems / sysv-fs.txt
blob253b50d1328ed8d62e873f9e6ca750972bc603ce
1 It implements all of
2   - Xenix FS,
3   - SystemV/386 FS,
4   - Coherent FS.
6 To install:
7 * Answer the 'System V and Coherent filesystem support' question with 'y'
8   when configuring the kernel.
9 * To mount a disk or a partition, use
10     mount [-r] -t sysv device mountpoint
11   The file system type names
12                -t sysv
13                -t xenix
14                -t coherent
15   may be used interchangeably, but the last two will eventually disappear.
17 Bugs in the present implementation:
18 - Coherent FS:
19   - The "free list interleave" n:m is currently ignored.
20   - Only file systems with no filesystem name and no pack name are recognized.
21   (See Coherent "man mkfs" for a description of these features.)
22 - SystemV Release 2 FS:
23   The superblock is only searched in the blocks 9, 15, 18, which
24   corresponds to the beginning of track 1 on floppy disks. No support
25   for this FS on hard disk yet.
28 These filesystems are rather similar. Here is a comparison with Minix FS:
30 * Linux fdisk reports on partitions
31   - Minix FS     0x81 Linux/Minix
32   - Xenix FS     ??
33   - SystemV FS   ??
34   - Coherent FS  0x08 AIX bootable
36 * Size of a block or zone (data allocation unit on disk)
37   - Minix FS     1024
38   - Xenix FS     1024 (also 512 ??)
39   - SystemV FS   1024 (also 512 and 2048)
40   - Coherent FS   512
42 * General layout: all have one boot block, one super block and
43   separate areas for inodes and for directories/data.
44   On SystemV Release 2 FS (e.g. Microport) the first track is reserved and
45   all the block numbers (including the super block) are offset by one track.
47 * Byte ordering of "short" (16 bit entities) on disk:
48   - Minix FS     little endian  0 1
49   - Xenix FS     little endian  0 1
50   - SystemV FS   little endian  0 1
51   - Coherent FS  little endian  0 1
52   Of course, this affects only the file system, not the data of files on it!
54 * Byte ordering of "long" (32 bit entities) on disk:
55   - Minix FS     little endian  0 1 2 3
56   - Xenix FS     little endian  0 1 2 3
57   - SystemV FS   little endian  0 1 2 3
58   - Coherent FS  PDP-11         2 3 0 1
59   Of course, this affects only the file system, not the data of files on it!
61 * Inode on disk: "short", 0 means non-existent, the root dir ino is:
62   - Minix FS                            1
63   - Xenix FS, SystemV FS, Coherent FS   2
65 * Maximum number of hard links to a file:
66   - Minix FS     250
67   - Xenix FS     ??
68   - SystemV FS   ??
69   - Coherent FS  >=10000
71 * Free inode management:
72   - Minix FS                             a bitmap
73   - Xenix FS, SystemV FS, Coherent FS
74       There is a cache of a certain number of free inodes in the super-block.
75       When it is exhausted, new free inodes are found using a linear search.
77 * Free block management:
78   - Minix FS                             a bitmap
79   - Xenix FS, SystemV FS, Coherent FS
80       Free blocks are organized in a "free list". Maybe a misleading term,
81       since it is not true that every free block contains a pointer to
82       the next free block. Rather, the free blocks are organized in chunks
83       of limited size, and every now and then a free block contains pointers
84       to the free blocks pertaining to the next chunk; the first of these
85       contains pointers and so on. The list terminates with a "block number"
86       0 on Xenix FS and SystemV FS, with a block zeroed out on Coherent FS.
88 * Super-block location:
89   - Minix FS     block 1 = bytes 1024..2047
90   - Xenix FS     block 1 = bytes 1024..2047
91   - SystemV FS   bytes 512..1023
92   - Coherent FS  block 1 = bytes 512..1023
94 * Super-block layout:
95   - Minix FS
96                     unsigned short s_ninodes;
97                     unsigned short s_nzones;
98                     unsigned short s_imap_blocks;
99                     unsigned short s_zmap_blocks;
100                     unsigned short s_firstdatazone;
101                     unsigned short s_log_zone_size;
102                     unsigned long s_max_size;
103                     unsigned short s_magic;
104   - Xenix FS, SystemV FS, Coherent FS
105                     unsigned short s_firstdatazone;
106                     unsigned long  s_nzones;
107                     unsigned short s_fzone_count;
108                     unsigned long  s_fzones[NICFREE];
109                     unsigned short s_finode_count;
110                     unsigned short s_finodes[NICINOD];
111                     char           s_flock;
112                     char           s_ilock;
113                     char           s_modified;
114                     char           s_rdonly;
115                     unsigned long  s_time;
116                     short          s_dinfo[4]; -- SystemV FS only
117                     unsigned long  s_free_zones;
118                     unsigned short s_free_inodes;
119                     short          s_dinfo[4]; -- Xenix FS only
120                     unsigned short s_interleave_m,s_interleave_n; -- Coherent FS only
121                     char           s_fname[6];
122                     char           s_fpack[6];
123     then they differ considerably:
124         Xenix FS
125                     char           s_clean;
126                     char           s_fill[371];
127                     long           s_magic;
128                     long           s_type;
129         SystemV FS
130                     long           s_fill[12 or 14];
131                     long           s_state;
132                     long           s_magic;
133                     long           s_type;
134         Coherent FS
135                     unsigned long  s_unique;
136     Note that Coherent FS has no magic.
138 * Inode layout:
139   - Minix FS
140                     unsigned short i_mode;
141                     unsigned short i_uid;
142                     unsigned long  i_size;
143                     unsigned long  i_time;
144                     unsigned char  i_gid;
145                     unsigned char  i_nlinks;
146                     unsigned short i_zone[7+1+1];
147   - Xenix FS, SystemV FS, Coherent FS
148                     unsigned short i_mode;
149                     unsigned short i_nlink;
150                     unsigned short i_uid;
151                     unsigned short i_gid;
152                     unsigned long  i_size;
153                     unsigned char  i_zone[3*(10+1+1+1)];
154                     unsigned long  i_atime;
155                     unsigned long  i_mtime;
156                     unsigned long  i_ctime;
158 * Regular file data blocks are organized as
159   - Minix FS
160                7 direct blocks
161                1 indirect block (pointers to blocks)
162                1 double-indirect block (pointer to pointers to blocks)
163   - Xenix FS, SystemV FS, Coherent FS
164               10 direct blocks
165                1 indirect block (pointers to blocks)
166                1 double-indirect block (pointer to pointers to blocks)
167                1 triple-indirect block (pointer to pointers to pointers to blocks)
169 * Inode size, inodes per block
170   - Minix FS        32   32
171   - Xenix FS        64   16
172   - SystemV FS      64   16
173   - Coherent FS     64    8
175 * Directory entry on disk
176   - Minix FS
177                     unsigned short inode;
178                     char name[14/30];
179   - Xenix FS, SystemV FS, Coherent FS
180                     unsigned short inode;
181                     char name[14];
183 * Dir entry size, dir entries per block
184   - Minix FS     16/32    64/32
185   - Xenix FS     16       64
186   - SystemV FS   16       64
187   - Coherent FS  16       32
189 * How to implement symbolic links such that the host fsck doesn't scream:
190   - Minix FS     normal
191   - Xenix FS     kludge: as regular files with  chmod 1000
192   - SystemV FS   ??
193   - Coherent FS  kludge: as regular files with  chmod 1000
196 Notation: We often speak of a "block" but mean a zone (the allocation unit)
197 and not the disk driver's notion of "block".