Add linux-next specific files for 20110831
[linux-2.6/next.git] / drivers / power / collie_battery.c
blob548d263b1ad0b1444cf65198c112e7c237b9f1bc
1 /*
2 * Battery and Power Management code for the Sharp SL-5x00
4 * Copyright (C) 2009 Thomas Kunze
6 * based on tosa_battery.c
8 * This program is free software; you can redistribute it and/or modify
9 * it under the terms of the GNU General Public License version 2 as
10 * published by the Free Software Foundation.
13 #include <linux/kernel.h>
14 #include <linux/module.h>
15 #include <linux/power_supply.h>
16 #include <linux/delay.h>
17 #include <linux/spinlock.h>
18 #include <linux/interrupt.h>
19 #include <linux/gpio.h>
20 #include <linux/mfd/ucb1x00.h>
22 #include <asm/mach/sharpsl_param.h>
23 #include <asm/mach-types.h>
24 #include <mach/collie.h>
26 static DEFINE_MUTEX(bat_lock); /* protects gpio pins */
27 static struct work_struct bat_work;
28 static struct ucb1x00 *ucb;
30 struct collie_bat {
31 int status;
32 struct power_supply psy;
33 int full_chrg;
35 struct mutex work_lock; /* protects data */
37 bool (*is_present)(struct collie_bat *bat);
38 int gpio_full;
39 int gpio_charge_on;
41 int technology;
43 int gpio_bat;
44 int adc_bat;
45 int adc_bat_divider;
46 int bat_max;
47 int bat_min;
49 int gpio_temp;
50 int adc_temp;
51 int adc_temp_divider;
54 static struct collie_bat collie_bat_main;
56 static unsigned long collie_read_bat(struct collie_bat *bat)
58 unsigned long value = 0;
60 if (bat->gpio_bat < 0 || bat->adc_bat < 0)
61 return 0;
62 mutex_lock(&bat_lock);
63 gpio_set_value(bat->gpio_bat, 1);
64 msleep(5);
65 ucb1x00_adc_enable(ucb);
66 value = ucb1x00_adc_read(ucb, bat->adc_bat, UCB_SYNC);
67 ucb1x00_adc_disable(ucb);
68 gpio_set_value(bat->gpio_bat, 0);
69 mutex_unlock(&bat_lock);
70 value = value * 1000000 / bat->adc_bat_divider;
72 return value;
75 static unsigned long collie_read_temp(struct collie_bat *bat)
77 unsigned long value = 0;
78 if (bat->gpio_temp < 0 || bat->adc_temp < 0)
79 return 0;
81 mutex_lock(&bat_lock);
82 gpio_set_value(bat->gpio_temp, 1);
83 msleep(5);
84 ucb1x00_adc_enable(ucb);
85 value = ucb1x00_adc_read(ucb, bat->adc_temp, UCB_SYNC);
86 ucb1x00_adc_disable(ucb);
87 gpio_set_value(bat->gpio_temp, 0);
88 mutex_unlock(&bat_lock);
90 value = value * 10000 / bat->adc_temp_divider;
92 return value;
95 static int collie_bat_get_property(struct power_supply *psy,
96 enum power_supply_property psp,
97 union power_supply_propval *val)
99 int ret = 0;
100 struct collie_bat *bat = container_of(psy, struct collie_bat, psy);
102 if (bat->is_present && !bat->is_present(bat)
103 && psp != POWER_SUPPLY_PROP_PRESENT) {
104 return -ENODEV;
107 switch (psp) {
108 case POWER_SUPPLY_PROP_STATUS:
109 val->intval = bat->status;
110 break;
111 case POWER_SUPPLY_PROP_TECHNOLOGY:
112 val->intval = bat->technology;
113 break;
114 case POWER_SUPPLY_PROP_VOLTAGE_NOW:
115 val->intval = collie_read_bat(bat);
116 break;
117 case POWER_SUPPLY_PROP_VOLTAGE_MAX:
118 if (bat->full_chrg == -1)
119 val->intval = bat->bat_max;
120 else
121 val->intval = bat->full_chrg;
122 break;
123 case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
124 val->intval = bat->bat_max;
125 break;
126 case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
127 val->intval = bat->bat_min;
128 break;
129 case POWER_SUPPLY_PROP_TEMP:
130 val->intval = collie_read_temp(bat);
131 break;
132 case POWER_SUPPLY_PROP_PRESENT:
133 val->intval = bat->is_present ? bat->is_present(bat) : 1;
134 break;
135 default:
136 ret = -EINVAL;
137 break;
139 return ret;
142 static void collie_bat_external_power_changed(struct power_supply *psy)
144 schedule_work(&bat_work);
147 static irqreturn_t collie_bat_gpio_isr(int irq, void *data)
149 pr_info("collie_bat_gpio irq: %d\n", gpio_get_value(irq_to_gpio(irq)));
150 schedule_work(&bat_work);
151 return IRQ_HANDLED;
154 static void collie_bat_update(struct collie_bat *bat)
156 int old;
157 struct power_supply *psy = &bat->psy;
159 mutex_lock(&bat->work_lock);
161 old = bat->status;
163 if (bat->is_present && !bat->is_present(bat)) {
164 printk(KERN_NOTICE "%s not present\n", psy->name);
165 bat->status = POWER_SUPPLY_STATUS_UNKNOWN;
166 bat->full_chrg = -1;
167 } else if (power_supply_am_i_supplied(psy)) {
168 if (bat->status == POWER_SUPPLY_STATUS_DISCHARGING) {
169 gpio_set_value(bat->gpio_charge_on, 1);
170 mdelay(15);
173 if (gpio_get_value(bat->gpio_full)) {
174 if (old == POWER_SUPPLY_STATUS_CHARGING ||
175 bat->full_chrg == -1)
176 bat->full_chrg = collie_read_bat(bat);
178 gpio_set_value(bat->gpio_charge_on, 0);
179 bat->status = POWER_SUPPLY_STATUS_FULL;
180 } else {
181 gpio_set_value(bat->gpio_charge_on, 1);
182 bat->status = POWER_SUPPLY_STATUS_CHARGING;
184 } else {
185 gpio_set_value(bat->gpio_charge_on, 0);
186 bat->status = POWER_SUPPLY_STATUS_DISCHARGING;
189 if (old != bat->status)
190 power_supply_changed(psy);
192 mutex_unlock(&bat->work_lock);
195 static void collie_bat_work(struct work_struct *work)
197 collie_bat_update(&collie_bat_main);
201 static enum power_supply_property collie_bat_main_props[] = {
202 POWER_SUPPLY_PROP_STATUS,
203 POWER_SUPPLY_PROP_TECHNOLOGY,
204 POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
205 POWER_SUPPLY_PROP_VOLTAGE_NOW,
206 POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
207 POWER_SUPPLY_PROP_VOLTAGE_MAX,
208 POWER_SUPPLY_PROP_PRESENT,
209 POWER_SUPPLY_PROP_TEMP,
212 static enum power_supply_property collie_bat_bu_props[] = {
213 POWER_SUPPLY_PROP_STATUS,
214 POWER_SUPPLY_PROP_TECHNOLOGY,
215 POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
216 POWER_SUPPLY_PROP_VOLTAGE_NOW,
217 POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
218 POWER_SUPPLY_PROP_VOLTAGE_MAX,
219 POWER_SUPPLY_PROP_PRESENT,
222 static struct collie_bat collie_bat_main = {
223 .status = POWER_SUPPLY_STATUS_DISCHARGING,
224 .full_chrg = -1,
225 .psy = {
226 .name = "main-battery",
227 .type = POWER_SUPPLY_TYPE_BATTERY,
228 .properties = collie_bat_main_props,
229 .num_properties = ARRAY_SIZE(collie_bat_main_props),
230 .get_property = collie_bat_get_property,
231 .external_power_changed = collie_bat_external_power_changed,
232 .use_for_apm = 1,
235 .gpio_full = COLLIE_GPIO_CO,
236 .gpio_charge_on = COLLIE_GPIO_CHARGE_ON,
238 .technology = POWER_SUPPLY_TECHNOLOGY_LIPO,
240 .gpio_bat = COLLIE_GPIO_MBAT_ON,
241 .adc_bat = UCB_ADC_INP_AD1,
242 .adc_bat_divider = 155,
243 .bat_max = 4310000,
244 .bat_min = 1551 * 1000000 / 414,
246 .gpio_temp = COLLIE_GPIO_TMP_ON,
247 .adc_temp = UCB_ADC_INP_AD0,
248 .adc_temp_divider = 10000,
251 static struct collie_bat collie_bat_bu = {
252 .status = POWER_SUPPLY_STATUS_UNKNOWN,
253 .full_chrg = -1,
255 .psy = {
256 .name = "backup-battery",
257 .type = POWER_SUPPLY_TYPE_BATTERY,
258 .properties = collie_bat_bu_props,
259 .num_properties = ARRAY_SIZE(collie_bat_bu_props),
260 .get_property = collie_bat_get_property,
261 .external_power_changed = collie_bat_external_power_changed,
264 .gpio_full = -1,
265 .gpio_charge_on = -1,
267 .technology = POWER_SUPPLY_TECHNOLOGY_LiMn,
269 .gpio_bat = COLLIE_GPIO_BBAT_ON,
270 .adc_bat = UCB_ADC_INP_AD1,
271 .adc_bat_divider = 155,
272 .bat_max = 3000000,
273 .bat_min = 1900000,
275 .gpio_temp = -1,
276 .adc_temp = -1,
277 .adc_temp_divider = -1,
280 static struct {
281 int gpio;
282 char *name;
283 bool output;
284 int value;
285 } gpios[] = {
286 { COLLIE_GPIO_CO, "main battery full", 0, 0 },
287 { COLLIE_GPIO_MAIN_BAT_LOW, "main battery low", 0, 0 },
288 { COLLIE_GPIO_CHARGE_ON, "main charge on", 1, 0 },
289 { COLLIE_GPIO_MBAT_ON, "main battery", 1, 0 },
290 { COLLIE_GPIO_TMP_ON, "main battery temp", 1, 0 },
291 { COLLIE_GPIO_BBAT_ON, "backup battery", 1, 0 },
294 #ifdef CONFIG_PM
295 static int collie_bat_suspend(struct ucb1x00_dev *dev, pm_message_t state)
297 /* flush all pending status updates */
298 flush_work_sync(&bat_work);
299 return 0;
302 static int collie_bat_resume(struct ucb1x00_dev *dev)
304 /* things may have changed while we were away */
305 schedule_work(&bat_work);
306 return 0;
308 #else
309 #define collie_bat_suspend NULL
310 #define collie_bat_resume NULL
311 #endif
313 static int __devinit collie_bat_probe(struct ucb1x00_dev *dev)
315 int ret;
316 int i;
318 if (!machine_is_collie())
319 return -ENODEV;
321 ucb = dev->ucb;
323 for (i = 0; i < ARRAY_SIZE(gpios); i++) {
324 ret = gpio_request(gpios[i].gpio, gpios[i].name);
325 if (ret) {
326 i--;
327 goto err_gpio;
330 if (gpios[i].output)
331 ret = gpio_direction_output(gpios[i].gpio,
332 gpios[i].value);
333 else
334 ret = gpio_direction_input(gpios[i].gpio);
336 if (ret)
337 goto err_gpio;
340 mutex_init(&collie_bat_main.work_lock);
342 INIT_WORK(&bat_work, collie_bat_work);
344 ret = power_supply_register(&dev->ucb->dev, &collie_bat_main.psy);
345 if (ret)
346 goto err_psy_reg_main;
347 ret = power_supply_register(&dev->ucb->dev, &collie_bat_bu.psy);
348 if (ret)
349 goto err_psy_reg_bu;
351 ret = request_irq(gpio_to_irq(COLLIE_GPIO_CO),
352 collie_bat_gpio_isr,
353 IRQF_TRIGGER_RISING | IRQF_TRIGGER_FALLING,
354 "main full", &collie_bat_main);
355 if (!ret) {
356 schedule_work(&bat_work);
357 return 0;
359 power_supply_unregister(&collie_bat_bu.psy);
360 err_psy_reg_bu:
361 power_supply_unregister(&collie_bat_main.psy);
362 err_psy_reg_main:
364 /* see comment in collie_bat_remove */
365 cancel_work_sync(&bat_work);
367 i--;
368 err_gpio:
369 for (; i >= 0; i--)
370 gpio_free(gpios[i].gpio);
372 return ret;
375 static void __devexit collie_bat_remove(struct ucb1x00_dev *dev)
377 int i;
379 free_irq(gpio_to_irq(COLLIE_GPIO_CO), &collie_bat_main);
381 power_supply_unregister(&collie_bat_bu.psy);
382 power_supply_unregister(&collie_bat_main.psy);
385 * Now cancel the bat_work. We won't get any more schedules,
386 * since all sources (isr and external_power_changed) are
387 * unregistered now.
389 cancel_work_sync(&bat_work);
391 for (i = ARRAY_SIZE(gpios) - 1; i >= 0; i--)
392 gpio_free(gpios[i].gpio);
395 static struct ucb1x00_driver collie_bat_driver = {
396 .add = collie_bat_probe,
397 .remove = __devexit_p(collie_bat_remove),
398 .suspend = collie_bat_suspend,
399 .resume = collie_bat_resume,
402 static int __init collie_bat_init(void)
404 return ucb1x00_register_driver(&collie_bat_driver);
407 static void __exit collie_bat_exit(void)
409 ucb1x00_unregister_driver(&collie_bat_driver);
412 module_init(collie_bat_init);
413 module_exit(collie_bat_exit);
415 MODULE_LICENSE("GPL");
416 MODULE_AUTHOR("Thomas Kunze");
417 MODULE_DESCRIPTION("Collie battery driver");