2 # Block device driver configuration
7 menu "Multi-device support (RAID and LVM)"
10 bool "Multiple devices driver support (RAID and LVM)"
12 Support multiple physical spindles through a single logical device.
13 Required for RAID and logical volume management.
16 tristate "RAID support"
19 This driver lets you combine several hard disk partitions into one
20 logical block device. This can be used to simply append one
21 partition to another one or to combine several redundant hard disks
22 into a RAID1/4/5 device so as to provide protection against hard
23 disk failures. This is called "Software RAID" since the combining of
24 the partitions is done by the kernel. "Hardware RAID" means that the
25 combining is done by a dedicated controller; if you have such a
26 controller, you do not need to say Y here.
28 More information about Software RAID on Linux is contained in the
29 Software RAID mini-HOWTO, available from
30 <http://www.tldp.org/docs.html#howto>. There you will also learn
31 where to get the supporting user space utilities raidtools.
36 tristate "Linear (append) mode"
39 If you say Y here, then your multiple devices driver will be able to
40 use the so-called linear mode, i.e. it will combine the hard disk
41 partitions by simply appending one to the other.
43 To compile this as a module, choose M here: the module
44 will be called linear.
49 tristate "RAID-0 (striping) mode"
52 If you say Y here, then your multiple devices driver will be able to
53 use the so-called raid0 mode, i.e. it will combine the hard disk
54 partitions into one logical device in such a fashion as to fill them
55 up evenly, one chunk here and one chunk there. This will increase
56 the throughput rate if the partitions reside on distinct disks.
58 Information about Software RAID on Linux is contained in the
59 Software-RAID mini-HOWTO, available from
60 <http://www.tldp.org/docs.html#howto>. There you will also
61 learn where to get the supporting user space utilities raidtools.
63 To compile this as a module, choose M here: the module
69 tristate "RAID-1 (mirroring) mode"
72 A RAID-1 set consists of several disk drives which are exact copies
73 of each other. In the event of a mirror failure, the RAID driver
74 will continue to use the operational mirrors in the set, providing
75 an error free MD (multiple device) to the higher levels of the
76 kernel. In a set with N drives, the available space is the capacity
77 of a single drive, and the set protects against a failure of (N - 1)
80 Information about Software RAID on Linux is contained in the
81 Software-RAID mini-HOWTO, available from
82 <http://www.tldp.org/docs.html#howto>. There you will also
83 learn where to get the supporting user space utilities raidtools.
85 If you want to use such a RAID-1 set, say Y. To compile this code
86 as a module, choose M here: the module will be called raid1.
91 tristate "RAID-10 (mirrored striping) mode (EXPERIMENTAL)"
92 depends on BLK_DEV_MD && EXPERIMENTAL
94 RAID-10 provides a combination of striping (RAID-0) and
95 mirroring (RAID-1) with easier configuration and more flexible
97 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
98 be the same size (or at least, only as much as the smallest device
100 RAID-10 provides a variety of layouts that provide different levels
101 of redundancy and performance.
103 RAID-10 requires mdadm-1.7.0 or later, available at:
105 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
110 tristate "RAID-4/RAID-5/RAID-6 mode"
111 depends on BLK_DEV_MD
115 A RAID-5 set of N drives with a capacity of C MB per drive provides
116 the capacity of C * (N - 1) MB, and protects against a failure
117 of a single drive. For a given sector (row) number, (N - 1) drives
118 contain data sectors, and one drive contains the parity protection.
119 For a RAID-4 set, the parity blocks are present on a single drive,
120 while a RAID-5 set distributes the parity across the drives in one
121 of the available parity distribution methods.
123 A RAID-6 set of N drives with a capacity of C MB per drive
124 provides the capacity of C * (N - 2) MB, and protects
125 against a failure of any two drives. For a given sector
126 (row) number, (N - 2) drives contain data sectors, and two
127 drives contains two independent redundancy syndromes. Like
128 RAID-5, RAID-6 distributes the syndromes across the drives
129 in one of the available parity distribution methods.
131 Information about Software RAID on Linux is contained in the
132 Software-RAID mini-HOWTO, available from
133 <http://www.tldp.org/docs.html#howto>. There you will also
134 learn where to get the supporting user space utilities raidtools.
136 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
137 compile this code as a module, choose M here: the module
138 will be called raid456.
142 config MD_RAID5_RESHAPE
143 bool "Support adding drives to a raid-5 array"
144 depends on MD_RAID456
147 A RAID-5 set can be expanded by adding extra drives. This
148 requires "restriping" the array which means (almost) every
149 block must be written to a different place.
151 This option allows such restriping to be done while the array
154 You will need mdadm version 2.4.1 or later to use this
155 feature safely. During the early stage of reshape there is
156 a critical section where live data is being over-written. A
157 crash during this time needs extra care for recovery. The
158 newer mdadm takes a copy of the data in the critical section
159 and will restore it, if necessary, after a crash.
161 The mdadm usage is e.g.
162 mdadm --grow /dev/md1 --raid-disks=6
163 to grow '/dev/md1' to having 6 disks.
165 Note: The array can only be expanded, not contracted.
166 There should be enough spares already present to make the new
172 tristate "Multipath I/O support"
173 depends on BLK_DEV_MD
175 Multipath-IO is the ability of certain devices to address the same
176 physical disk over multiple 'IO paths'. The code ensures that such
177 paths can be defined and handled at runtime, and ensures that a
178 transparent failover to the backup path(s) happens if a IO errors
179 arrives on the primary path.
184 tristate "Faulty test module for MD"
185 depends on BLK_DEV_MD
187 The "faulty" module allows for a block device that occasionally returns
188 read or write errors. It is useful for testing.
193 tristate "Device mapper support"
196 Device-mapper is a low level volume manager. It works by allowing
197 people to specify mappings for ranges of logical sectors. Various
198 mapping types are available, in addition people may write their own
199 modules containing custom mappings if they wish.
201 Higher level volume managers such as LVM2 use this driver.
203 To compile this as a module, choose M here: the module will be
209 boolean "Device mapper debugging support"
210 depends on BLK_DEV_DM && EXPERIMENTAL
212 Enable this for messages that may help debug device-mapper problems.
217 tristate "Crypt target support"
218 depends on BLK_DEV_DM && EXPERIMENTAL
222 This device-mapper target allows you to create a device that
223 transparently encrypts the data on it. You'll need to activate
224 the ciphers you're going to use in the cryptoapi configuration.
226 Information on how to use dm-crypt can be found on
228 <http://www.saout.de/misc/dm-crypt/>
230 To compile this code as a module, choose M here: the module will
236 tristate "Snapshot target (EXPERIMENTAL)"
237 depends on BLK_DEV_DM && EXPERIMENTAL
239 Allow volume managers to take writable snapshots of a device.
242 tristate "Mirror target (EXPERIMENTAL)"
243 depends on BLK_DEV_DM && EXPERIMENTAL
245 Allow volume managers to mirror logical volumes, also
246 needed for live data migration tools such as 'pvmove'.
249 tristate "Zero target (EXPERIMENTAL)"
250 depends on BLK_DEV_DM && EXPERIMENTAL
252 A target that discards writes, and returns all zeroes for
253 reads. Useful in some recovery situations.
256 tristate "Multipath target (EXPERIMENTAL)"
257 depends on BLK_DEV_DM && EXPERIMENTAL
259 Allow volume managers to support multipath hardware.
261 config DM_MULTIPATH_EMC
262 tristate "EMC CX/AX multipath support (EXPERIMENTAL)"
263 depends on DM_MULTIPATH && BLK_DEV_DM && EXPERIMENTAL
265 Multipath support for EMC CX/AX series hardware.
267 config DM_MULTIPATH_RDAC
268 tristate "LSI/Engenio RDAC multipath support (EXPERIMENTAL)"
269 depends on DM_MULTIPATH && BLK_DEV_DM && EXPERIMENTAL
271 Multipath support for LSI/Engenio RDAC.
274 tristate "I/O delaying target (EXPERIMENTAL)"
275 depends on BLK_DEV_DM && EXPERIMENTAL
277 A target that delays reads and/or writes and can send
278 them to different devices. Useful for testing.