[ARM] pxa: update defconfig for Verdex Pro
[linux-2.6/verdex.git] / arch / s390 / Kconfig
blob43c0acad7160e55eef1bc719c39111a3cdf97a14
2 # For a description of the syntax of this configuration file,
3 # see Documentation/kbuild/kconfig-language.txt.
6 config SCHED_MC
7         def_bool y
8         depends on SMP
10 config MMU
11         def_bool y
13 config ZONE_DMA
14         def_bool y
15         depends on 64BIT
17 config LOCKDEP_SUPPORT
18         def_bool y
20 config STACKTRACE_SUPPORT
21         def_bool y
23 config HAVE_LATENCYTOP_SUPPORT
24         def_bool y
26 config RWSEM_GENERIC_SPINLOCK
27         bool
29 config RWSEM_XCHGADD_ALGORITHM
30         def_bool y
32 config ARCH_HAS_ILOG2_U32
33         bool
34         default n
36 config ARCH_HAS_ILOG2_U64
37         bool
38         default n
40 config GENERIC_HWEIGHT
41         def_bool y
43 config GENERIC_TIME
44         def_bool y
46 config GENERIC_TIME_VSYSCALL
47         def_bool y
49 config GENERIC_CLOCKEVENTS
50         def_bool y
52 config GENERIC_BUG
53         bool
54         depends on BUG
55         default y
57 config NO_IOMEM
58         def_bool y
60 config NO_DMA
61         def_bool y
63 config GENERIC_LOCKBREAK
64         bool
65         default y
66         depends on SMP && PREEMPT
68 config PGSTE
69         bool
70         default y if KVM
72 config VIRT_CPU_ACCOUNTING
73         def_bool y
75 config ARCH_SUPPORTS_DEBUG_PAGEALLOC
76         def_bool y
78 mainmenu "Linux Kernel Configuration"
80 config S390
81         def_bool y
82         select USE_GENERIC_SMP_HELPERS if SMP
83         select HAVE_SYSCALL_WRAPPERS
84         select HAVE_FUNCTION_TRACER
85         select HAVE_FUNCTION_TRACE_MCOUNT_TEST
86         select HAVE_FTRACE_MCOUNT_RECORD
87         select HAVE_SYSCALL_TRACEPOINTS
88         select HAVE_DYNAMIC_FTRACE
89         select HAVE_FUNCTION_GRAPH_TRACER
90         select HAVE_DEFAULT_NO_SPIN_MUTEXES
91         select HAVE_OPROFILE
92         select HAVE_KPROBES
93         select HAVE_KRETPROBES
94         select HAVE_KVM if 64BIT
95         select HAVE_ARCH_TRACEHOOK
96         select INIT_ALL_POSSIBLE
97         select HAVE_PERF_EVENTS
99 config SCHED_OMIT_FRAME_POINTER
100         bool
101         default y
103 source "init/Kconfig"
105 source "kernel/Kconfig.freezer"
107 menu "Base setup"
109 comment "Processor type and features"
111 source "kernel/time/Kconfig"
113 config 64BIT
114         bool "64 bit kernel"
115         help
116           Select this option if you have a 64 bit IBM zSeries machine
117           and want to use the 64 bit addressing mode.
119 config 32BIT
120         bool
121         default y if !64BIT
123 config KTIME_SCALAR
124         def_bool 32BIT
126 config SMP
127         bool "Symmetric multi-processing support"
128         ---help---
129           This enables support for systems with more than one CPU. If you have
130           a system with only one CPU, like most personal computers, say N. If
131           you have a system with more than one CPU, say Y.
133           If you say N here, the kernel will run on single and multiprocessor
134           machines, but will use only one CPU of a multiprocessor machine. If
135           you say Y here, the kernel will run on many, but not all,
136           singleprocessor machines. On a singleprocessor machine, the kernel
137           will run faster if you say N here.
139           See also the SMP-HOWTO available at
140           <http://www.tldp.org/docs.html#howto>.
142           Even if you don't know what to do here, say Y.
144 config NR_CPUS
145         int "Maximum number of CPUs (2-64)"
146         range 2 64
147         depends on SMP
148         default "32" if !64BIT
149         default "64" if 64BIT
150         help
151           This allows you to specify the maximum number of CPUs which this
152           kernel will support.  The maximum supported value is 64 and the
153           minimum value which makes sense is 2.
155           This is purely to save memory - each supported CPU adds
156           approximately sixteen kilobytes to the kernel image.
158 config HOTPLUG_CPU
159         bool "Support for hot-pluggable CPUs"
160         depends on SMP
161         select HOTPLUG
162         default n
163         help
164           Say Y here to be able to turn CPUs off and on. CPUs
165           can be controlled through /sys/devices/system/cpu/cpu#.
166           Say N if you want to disable CPU hotplug.
168 config MATHEMU
169         bool "IEEE FPU emulation"
170         depends on MARCH_G5
171         help
172           This option is required for IEEE compliant floating point arithmetic
173           on older S/390 machines. Say Y unless you know your machine doesn't
174           need this.
176 config COMPAT
177         bool "Kernel support for 31 bit emulation"
178         depends on 64BIT
179         select COMPAT_BINFMT_ELF
180         help
181           Select this option if you want to enable your system kernel to
182           handle system-calls from ELF binaries for 31 bit ESA.  This option
183           (and some other stuff like libraries and such) is needed for
184           executing 31 bit applications.  It is safe to say "Y".
186 config SYSVIPC_COMPAT
187         bool
188         depends on COMPAT && SYSVIPC
189         default y
191 config AUDIT_ARCH
192         bool
193         default y
195 config S390_SWITCH_AMODE
196         bool "Switch kernel/user addressing modes"
197         help
198           This option allows to switch the addressing modes of kernel and user
199           space. The kernel parameter switch_amode=on will enable this feature,
200           default is disabled. Enabling this (via kernel parameter) on machines
201           earlier than IBM System z9-109 EC/BC will reduce system performance.
203           Note that this option will also be selected by selecting the execute
204           protection option below. Enabling the execute protection via the
205           noexec kernel parameter will also switch the addressing modes,
206           independent of the switch_amode kernel parameter.
209 config S390_EXEC_PROTECT
210         bool "Data execute protection"
211         select S390_SWITCH_AMODE
212         help
213           This option allows to enable a buffer overflow protection for user
214           space programs and it also selects the addressing mode option above.
215           The kernel parameter noexec=on will enable this feature and also
216           switch the addressing modes, default is disabled. Enabling this (via
217           kernel parameter) on machines earlier than IBM System z9-109 EC/BC
218           will reduce system performance.
220 comment "Code generation options"
222 choice
223         prompt "Processor type"
224         default MARCH_G5
226 config MARCH_G5
227         bool "S/390 model G5 and G6"
228         depends on !64BIT
229         help
230           Select this to build a 31 bit kernel that works
231           on all S/390 and zSeries machines.
233 config MARCH_Z900
234         bool "IBM eServer zSeries model z800 and z900"
235         help
236           Select this to optimize for zSeries machines. This
237           will enable some optimizations that are not available
238           on older 31 bit only CPUs.
240 config MARCH_Z990
241         bool "IBM eServer zSeries model z890 and z990"
242         help
243           Select this enable optimizations for model z890/z990.
244           This will be slightly faster but does not work on
245           older machines such as the z900.
247 config MARCH_Z9_109
248         bool "IBM System z9"
249         help
250           Select this to enable optimizations for IBM System z9-109, IBM
251           System z9 Enterprise Class (z9 EC), and IBM System z9 Business
252           Class (z9 BC). The kernel will be slightly faster but will not
253           work on older machines such as the z990, z890, z900, and z800.
255 config MARCH_Z10
256         bool "IBM System z10"
257         help
258           Select this to enable optimizations for IBM System z10. The
259           kernel will be slightly faster but will not work on older
260           machines such as the z990, z890, z900, z800, z9-109, z9-ec
261           and z9-bc.
263 endchoice
265 config PACK_STACK
266         bool "Pack kernel stack"
267         help
268           This option enables the compiler option -mkernel-backchain if it
269           is available. If the option is available the compiler supports
270           the new stack layout which dramatically reduces the minimum stack
271           frame size. With an old compiler a non-leaf function needs a
272           minimum of 96 bytes on 31 bit and 160 bytes on 64 bit. With
273           -mkernel-backchain the minimum size drops to 16 byte on 31 bit
274           and 24 byte on 64 bit.
276           Say Y if you are unsure.
278 config SMALL_STACK
279         bool "Use 8kb for kernel stack instead of 16kb"
280         depends on PACK_STACK && 64BIT && !LOCKDEP
281         help
282           If you say Y here and the compiler supports the -mkernel-backchain
283           option the kernel will use a smaller kernel stack size. The reduced
284           size is 8kb instead of 16kb. This allows to run more threads on a
285           system and reduces the pressure on the memory management for higher
286           order page allocations.
288           Say N if you are unsure.
290 config CHECK_STACK
291         bool "Detect kernel stack overflow"
292         help
293           This option enables the compiler option -mstack-guard and
294           -mstack-size if they are available. If the compiler supports them
295           it will emit additional code to each function prolog to trigger
296           an illegal operation if the kernel stack is about to overflow.
298           Say N if you are unsure.
300 config STACK_GUARD
301         int "Size of the guard area (128-1024)"
302         range 128 1024
303         depends on CHECK_STACK
304         default "256"
305         help
306           This allows you to specify the size of the guard area at the lower
307           end of the kernel stack. If the kernel stack points into the guard
308           area on function entry an illegal operation is triggered. The size
309           needs to be a power of 2. Please keep in mind that the size of an
310           interrupt frame is 184 bytes for 31 bit and 328 bytes on 64 bit.
311           The minimum size for the stack guard should be 256 for 31 bit and
312           512 for 64 bit.
314 config WARN_STACK
315         bool "Emit compiler warnings for function with broken stack usage"
316         help
317           This option enables the compiler options -mwarn-framesize and
318           -mwarn-dynamicstack. If the compiler supports these options it
319           will generate warnings for function which either use alloca or
320           create a stack frame bigger than CONFIG_WARN_STACK_SIZE.
322           Say N if you are unsure.
324 config WARN_STACK_SIZE
325         int "Maximum frame size considered safe (128-2048)"
326         range 128 2048
327         depends on WARN_STACK
328         default "2048"
329         help
330           This allows you to specify the maximum frame size a function may
331           have without the compiler complaining about it.
333 config ARCH_POPULATES_NODE_MAP
334         def_bool y
336 comment "Kernel preemption"
338 source "kernel/Kconfig.preempt"
340 config ARCH_SPARSEMEM_ENABLE
341         def_bool y
342         select SPARSEMEM_VMEMMAP_ENABLE
343         select SPARSEMEM_VMEMMAP
344         select SPARSEMEM_STATIC if !64BIT
346 config ARCH_SPARSEMEM_DEFAULT
347         def_bool y
349 config ARCH_SELECT_MEMORY_MODEL
350        def_bool y
352 config ARCH_ENABLE_MEMORY_HOTPLUG
353         def_bool y
354         depends on SPARSEMEM
356 config ARCH_ENABLE_MEMORY_HOTREMOVE
357         def_bool y
359 config ARCH_HIBERNATION_POSSIBLE
360        def_bool y if 64BIT
362 source "mm/Kconfig"
364 comment "I/O subsystem configuration"
366 config QDIO
367         tristate "QDIO support"
368         ---help---
369           This driver provides the Queued Direct I/O base support for
370           IBM System z.
372           To compile this driver as a module, choose M here: the
373           module will be called qdio.
375           If unsure, say Y.
377 config CHSC_SCH
378         tristate "Support for CHSC subchannels"
379         help
380           This driver allows usage of CHSC subchannels. A CHSC subchannel
381           is usually present on LPAR only.
382           The driver creates a device /dev/chsc, which may be used to
383           obtain I/O configuration information about the machine and
384           to issue asynchronous chsc commands (DANGEROUS).
385           You will usually only want to use this interface on a special
386           LPAR designated for system management.
388           To compile this driver as a module, choose M here: the
389           module will be called chsc_sch.
391           If unsure, say N.
393 comment "Misc"
395 config IPL
396         bool "Builtin IPL record support"
397         help
398           If you want to use the produced kernel to IPL directly from a
399           device, you have to merge a bootsector specific to the device
400           into the first bytes of the kernel. You will have to select the
401           IPL device.
403 choice
404         prompt "IPL method generated into head.S"
405         depends on IPL
406         default IPL_VM
407         help
408           Select "tape" if you want to IPL the image from a Tape.
410           Select "vm_reader" if you are running under VM/ESA and want
411           to IPL the image from the emulated card reader.
413 config IPL_TAPE
414         bool "tape"
416 config IPL_VM
417         bool "vm_reader"
419 endchoice
421 source "fs/Kconfig.binfmt"
423 config FORCE_MAX_ZONEORDER
424         int
425         default "9"
427 config PROCESS_DEBUG
428         bool "Show crashed user process info"
429         help
430           Say Y to print all process fault locations to the console.  This is
431           a debugging option; you probably do not want to set it unless you
432           are an S390 port maintainer.
434 config PFAULT
435         bool "Pseudo page fault support"
436         help
437           Select this option, if you want to use PFAULT pseudo page fault
438           handling under VM. If running native or in LPAR, this option
439           has no effect. If your VM does not support PFAULT, PAGEEX
440           pseudo page fault handling will be used.
441           Note that VM 4.2 supports PFAULT but has a bug in its
442           implementation that causes some problems.
443           Everybody who wants to run Linux under VM != VM4.2 should select
444           this option.
446 config SHARED_KERNEL
447         bool "VM shared kernel support"
448         help
449           Select this option, if you want to share the text segment of the
450           Linux kernel between different VM guests. This reduces memory
451           usage with lots of guests but greatly increases kernel size.
452           Also if a kernel was IPL'ed from a shared segment the kexec system
453           call will not work.
454           You should only select this option if you know what you are
455           doing and want to exploit this feature.
457 config CMM
458         tristate "Cooperative memory management"
459         help
460           Select this option, if you want to enable the kernel interface
461           to reduce the memory size of the system. This is accomplished
462           by allocating pages of memory and put them "on hold". This only
463           makes sense for a system running under VM where the unused pages
464           will be reused by VM for other guest systems. The interface
465           allows an external monitor to balance memory of many systems.
466           Everybody who wants to run Linux under VM should select this
467           option.
469 config CMM_PROC
470         bool "/proc interface to cooperative memory management"
471         depends on CMM
472         help
473           Select this option to enable the /proc interface to the
474           cooperative memory management.
476 config CMM_IUCV
477         bool "IUCV special message interface to cooperative memory management"
478         depends on CMM && (SMSGIUCV=y || CMM=SMSGIUCV)
479         help
480           Select this option to enable the special message interface to
481           the cooperative memory management.
483 config APPLDATA_BASE
484         bool "Linux - VM Monitor Stream, base infrastructure"
485         depends on PROC_FS
486         help
487           This provides a kernel interface for creating and updating z/VM APPLDATA
488           monitor records. The monitor records are updated at certain time
489           intervals, once the timer is started.
490           Writing 1 or 0 to /proc/appldata/timer starts(1) or stops(0) the timer,
491           i.e. enables or disables monitoring on the Linux side.
492           A custom interval value (in seconds) can be written to
493           /proc/appldata/interval.
495           Defaults are 60 seconds interval and timer off.
496           The /proc entries can also be read from, showing the current settings.
498 config APPLDATA_MEM
499         tristate "Monitor memory management statistics"
500         depends on APPLDATA_BASE && VM_EVENT_COUNTERS
501         help
502           This provides memory management related data to the Linux - VM Monitor
503           Stream, like paging/swapping rate, memory utilisation, etc.
504           Writing 1 or 0 to /proc/appldata/memory creates(1) or removes(0) a z/VM
505           APPLDATA monitor record, i.e. enables or disables monitoring this record
506           on the z/VM side.
508           Default is disabled.
509           The /proc entry can also be read from, showing the current settings.
511           This can also be compiled as a module, which will be called
512           appldata_mem.o.
514 config APPLDATA_OS
515         tristate "Monitor OS statistics"
516         depends on APPLDATA_BASE
517         help
518           This provides OS related data to the Linux - VM Monitor Stream, like
519           CPU utilisation, etc.
520           Writing 1 or 0 to /proc/appldata/os creates(1) or removes(0) a z/VM
521           APPLDATA monitor record, i.e. enables or disables monitoring this record
522           on the z/VM side.
524           Default is disabled.
525           This can also be compiled as a module, which will be called
526           appldata_os.o.
528 config APPLDATA_NET_SUM
529         tristate "Monitor overall network statistics"
530         depends on APPLDATA_BASE && NET
531         help
532           This provides network related data to the Linux - VM Monitor Stream,
533           currently there is only a total sum of network I/O statistics, no
534           per-interface data.
535           Writing 1 or 0 to /proc/appldata/net_sum creates(1) or removes(0) a z/VM
536           APPLDATA monitor record, i.e. enables or disables monitoring this record
537           on the z/VM side.
539           Default is disabled.
540           This can also be compiled as a module, which will be called
541           appldata_net_sum.o.
543 source kernel/Kconfig.hz
545 config S390_HYPFS_FS
546         bool "s390 hypervisor file system support"
547         select SYS_HYPERVISOR
548         default y
549         help
550           This is a virtual file system intended to provide accounting
551           information in an s390 hypervisor environment.
553 config KEXEC
554         bool "kexec system call"
555         help
556           kexec is a system call that implements the ability to shutdown your
557           current kernel, and to start another kernel.  It is like a reboot
558           but is independent of hardware/microcode support.
560 config ZFCPDUMP
561         bool "zfcpdump support"
562         select SMP
563         default n
564         help
565           Select this option if you want to build an zfcpdump enabled kernel.
566           Refer to <file:Documentation/s390/zfcpdump.txt> for more details on this.
568 config S390_GUEST
569 bool "s390 guest support for KVM (EXPERIMENTAL)"
570         depends on 64BIT && EXPERIMENTAL
571         select VIRTIO
572         select VIRTIO_RING
573         select VIRTIO_CONSOLE
574         help
575           Select this option if you want to run the kernel as a guest under
576           the KVM hypervisor. This will add detection for KVM as well  as a
577           virtio transport. If KVM is detected, the virtio console will be
578           the default console.
580 config SECCOMP
581         bool "Enable seccomp to safely compute untrusted bytecode"
582         depends on PROC_FS
583         default y
584         help
585           This kernel feature is useful for number crunching applications
586           that may need to compute untrusted bytecode during their
587           execution. By using pipes or other transports made available to
588           the process as file descriptors supporting the read/write
589           syscalls, it's possible to isolate those applications in
590           their own address space using seccomp. Once seccomp is
591           enabled via /proc/<pid>/seccomp, it cannot be disabled
592           and the task is only allowed to execute a few safe syscalls
593           defined by each seccomp mode.
595           If unsure, say Y.
597 endmenu
599 menu "Power Management"
601 source "kernel/power/Kconfig"
603 endmenu
605 source "net/Kconfig"
607 config PCMCIA
608         def_bool n
610 config CCW
611         def_bool y
613 source "drivers/Kconfig"
615 source "fs/Kconfig"
617 source "arch/s390/Kconfig.debug"
619 source "security/Kconfig"
621 source "crypto/Kconfig"
623 source "lib/Kconfig"
625 source "arch/s390/kvm/Kconfig"