1 Kernel driver tmp401
2 ====================
4 Supported chips:
5   * Texas Instruments TMP401
6     Prefix: 'tmp401'
7     Addresses scanned: I2C 0x4c
8     Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp401.html
9   * Texas Instruments TMP411
10     Prefix: 'tmp411'
11     Addresses scanned: I2C 0x4c
12     Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp411.html
14 Authors:
15          Hans de Goede <hdegoede@redhat.com>
16          Andre Prendel <andre.prendel@gmx.de>
18 Description
19 -----------
21 This driver implements support for Texas Instruments TMP401 and
22 TMP411 chips. These chips implements one remote and one local
23 temperature sensor. Temperature is measured in degrees
24 Celsius. Resolution of the remote sensor is 0.0625 degree. Local
25 sensor resolution can be set to 0.5, 0.25, 0.125 or 0.0625 degree (not
26 supported by the driver so far, so using the default resolution of 0.5
27 degree).
29 The driver provides the common sysfs-interface for temperatures (see
30 /Documentation/hwmon/sysfs-interface under Temperatures).
32 The TMP411 chip is compatible with TMP401. It provides some additional
33 features.
35 * Minimum and Maximum temperature measured since power-on, chip-reset
37   Exported via sysfs attributes tempX_lowest and tempX_highest.
39 * Reset of historical minimum/maximum temperature measurements
41   Exported via sysfs attribute temp_reset_history. Writing 1 to this