Linux 4.15.6
[linux/fpc-iii.git] / Documentation / hwmon / pc87427
blobc313eb66e08adb03eb6a71ea0553da3e47e96351
1 Kernel driver pc87427
2 =====================
4 Supported chips:
5   * National Semiconductor PC87427
6     Prefix: 'pc87427'
7     Addresses scanned: none, address read from Super I/O config space
8     Datasheet: No longer available
10 Author: Jean Delvare <jdelvare@suse.de>
12 Thanks to Amir Habibi at Candelis for setting up a test system, and to
13 Michael Kress for testing several iterations of this driver.
16 Description
17 -----------
19 The National Semiconductor Super I/O chip includes complete hardware
20 monitoring capabilities. It can monitor up to 18 voltages, 8 fans and
21 6 temperature sensors. Only the fans and temperatures are supported at
22 the moment, voltages aren't.
24 This chip also has fan controlling features (up to 4 PWM outputs),
25 which are partly supported by this driver.
27 The driver assumes that no more than one chip is present, which seems
28 reasonable.
31 Fan Monitoring
32 --------------
34 Fan rotation speeds are reported as 14-bit values from a gated clock
35 signal. Speeds down to 83 RPM can be measured.
37 An alarm is triggered if the rotation speed drops below a programmable
38 limit. Another alarm is triggered if the speed is too low to be measured
39 (including stalled or missing fan).
42 Fan Speed Control
43 -----------------
45 Fan speed can be controlled by PWM outputs. There are 4 possible modes:
46 always off, always on, manual and automatic. The latter isn't supported
47 by the driver: you can only return to that mode if it was the original
48 setting, and the configuration interface is missing.
51 Temperature Monitoring
52 ----------------------
54 The PC87427 relies on external sensors (following the SensorPath
55 standard), so the resolution and range depend on the type of sensor
56 connected. The integer part can be 8-bit or 9-bit, and can be signed or
57 not. I couldn't find a way to figure out the external sensor data
58 temperature format, so user-space adjustment (typically by a factor 2)
59 may be required.