1 What: /sys/.../events/in_illuminance0_thresh_either_en
4 Contact: Johan Hovold <jhovold@gmail.com>
6 Event generated when channel passes one of the four thresholds
7 in each direction (rising|falling) and a zone change occurs.
8 The corresponding light zone can be read from
11 What: /sys/.../events/in_illuminance0_threshY_hysteresis
14 Contact: Johan Hovold <jhovold@gmail.com>
16 Get the hysteresis for thresholds Y, that is,
17 threshY_hysteresis = threshY_raising - threshY_falling
19 What: /sys/.../events/illuminance_threshY_falling_value
20 What: /sys/.../events/illuminance_threshY_raising_value
23 Contact: Johan Hovold <jhovold@gmail.com>
25 Specifies the value of threshold that the device is comparing
26 against for the events enabled by
27 in_illuminance0_thresh_either_en (0..255), where Y in 0..3.
29 Note that threshY_falling must be less than or equal to
32 These thresholds correspond to the eight zone-boundary
33 registers (boundaryY_{low,high}) and define the five light
36 What: /sys/bus/iio/devices/iio:deviceX/in_illuminance0_zone
39 Contact: Johan Hovold <jhovold@gmail.com>
41 Get the current light zone (0..4) as defined by the
42 in_illuminance0_threshY_{falling,rising} thresholds.
44 What: /sys/bus/iio/devices/iio:deviceX/out_currentY_raw
47 Contact: Johan Hovold <jhovold@gmail.com>
49 Get output current for channel Y (0..255), that is,
50 out_currentY_currentZ_raw, where Z is the current zone.
52 What: /sys/bus/iio/devices/iio:deviceX/out_currentY_currentZ_raw
55 Contact: Johan Hovold <jhovold@gmail.com>
57 Set the output current for channel out_currentY when in zone
58 Z (0..255), where Y in 0..2 and Z in 0..4.
60 These values correspond to the ALS-mapper target registers for