3 The QCA7000 is a serial-to-powerline bridge with a host interface which could
4 be configured either as SPI or UART slave. This configuration is done by
9 In order to use the QCA7000 as SPI device it must be defined as a child of a
10 SPI master in the device tree.
13 - compatible : Should be "qca,qca7000"
14 - reg : Should specify the SPI chip select
15 - interrupts : The first cell should specify the index of the source
16 interrupt and the second cell should specify the trigger
18 - spi-cpha : Must be set
19 - spi-cpol : Must be set
22 - spi-max-frequency : Maximum frequency of the SPI bus the chip can operate at.
23 Numbers smaller than 1000000 or greater than 16000000
24 are invalid. Missing the property will set the SPI
25 frequency to 8000000 Hertz.
26 - qca,legacy-mode : Set the SPI data transfer of the QCA7000 to legacy mode.
27 In this mode the SPI master must toggle the chip select
28 between each data word. In burst mode these gaps aren't
29 necessary, which is faster. This setting depends on how
30 the QCA7000 is setup via GPIO pin strapping. If the
31 property is missing the driver defaults to burst mode.
33 The MAC address will be determined using the optional properties
34 defined in ethernet.txt.
38 /* Freescale i.MX28 SPI master*/
42 compatible = "fsl,imx28-spi";
43 pinctrl-names = "default";
44 pinctrl-0 = <&spi2_pins_a>;
47 compatible = "qca,qca7000";
49 interrupt-parent = <&gpio3>; /* GPIO Bank 3 */
50 interrupts = <25 0x1>; /* Index: 25, rising edge */
51 spi-cpha; /* SPI mode: CPHA=1 */
52 spi-cpol; /* SPI mode: CPOL=1 */
53 spi-max-frequency = <8000000>; /* freq: 8 MHz */
54 local-mac-address = [ A0 B0 C0 D0 E0 F0 ];
58 (b) Ethernet over UART
60 In order to use the QCA7000 as UART slave it must be defined as a child of a
61 UART master in the device tree. It is possible to preconfigure the UART
62 settings of the QCA7000 firmware, but it's not possible to change them during
66 - compatible : Should be "qca,qca7000"
69 - local-mac-address : see ./ethernet.txt
70 - current-speed : current baud rate of QCA7000 which defaults to 115200
71 if absent, see also ../serial/serial.yaml
75 /* Freescale i.MX28 UART */
76 auart0: serial@8006a000 {
77 compatible = "fsl,imx28-auart", "fsl,imx23-auart";
78 reg = <0x8006a000 0x2000>;
79 pinctrl-names = "default";
80 pinctrl-0 = <&auart0_2pins_a>;
83 compatible = "qca,qca7000";
84 local-mac-address = [ A0 B0 C0 D0 E0 F0 ];
85 current-speed = <38400>;