usbnet: increase URB reference count before usb_unlink_urb
[linux/fpc-iii.git] / Documentation / hwmon / lineage-pem
blob2ba5ed126858e467b46380319a0b5876ecc91d18
1 Kernel driver lineage-pem
2 =========================
4 Supported devices:
5   * Lineage Compact Power Line Power Entry Modules
6     Prefix: 'lineage-pem'
7     Addresses scanned: -
8     Documentation:
9         http://www.lineagepower.com/oem/pdf/CPLI2C.pdf
11 Author: Guenter Roeck <guenter.roeck@ericsson.com>
14 Description
15 -----------
17 This driver supports various Lineage Compact Power Line DC/DC and AC/DC
18 converters such as CP1800, CP2000AC, CP2000DC, CP2100DC, and others.
20 Lineage CPL power entry modules are nominally PMBus compliant. However, most
21 standard PMBus commands are not supported. Specifically, all hardware monitoring
22 and status reporting commands are non-standard. For this reason, a standard
23 PMBus driver can not be used.
26 Usage Notes
27 -----------
29 This driver does not probe for Lineage CPL devices, since there is no register
30 which can be safely used to identify the chip. You will have to instantiate
31 the devices explicitly.
33 Example: the following will load the driver for a Lineage PEM at address 0x40
34 on I2C bus #1:
35 $ modprobe lineage-pem
36 $ echo lineage-pem 0x40 > /sys/bus/i2c/devices/i2c-1/new_device
38 All Lineage CPL power entry modules have a built-in I2C bus master selector
39 (PCA9541). To ensure device access, this driver should only be used as client
40 driver to the pca9541 I2C master selector driver.
43 Sysfs entries
44 -------------
46 All Lineage CPL devices report output voltage and device temperature as well as
47 alarms for output voltage, temperature, input voltage, input current, input power,
48 and fan status.
50 Input voltage, input current, input power, and fan speed measurement is only
51 supported on newer devices. The driver detects if those attributes are supported,
52 and only creates respective sysfs entries if they are.
54 in1_input               Output voltage (mV)
55 in1_min_alarm           Output undervoltage alarm
56 in1_max_alarm           Output overvoltage alarm
57 in1_crit                Output voltage critical alarm
59 in2_input               Input voltage (mV, optional)
60 in2_alarm               Input voltage alarm
62 curr1_input             Input current (mA, optional)
63 curr1_alarm             Input overcurrent alarm
65 power1_input            Input power (uW, optional)
66 power1_alarm            Input power alarm
68 fan1_input              Fan 1 speed (rpm, optional)
69 fan2_input              Fan 2 speed (rpm, optional)
70 fan3_input              Fan 3 speed (rpm, optional)
72 temp1_input
73 temp1_max
74 temp1_crit
75 temp1_alarm
76 temp1_crit_alarm
77 temp1_fault