net: export NET_ADDR_* values to user-space API
[linux/fpc-iii.git] / Documentation / hwmon / max1619
blob518bae3a80c472245cf18421facdbd7fa41f4477
1 Kernel driver max1619
2 =====================
4 Supported chips:
5   * Maxim MAX1619
6     Prefix: 'max1619'
7     Addresses scanned: I2C 0x18-0x1a, 0x29-0x2b, 0x4c-0x4e
8     Datasheet: Publicly available at the Maxim website
9                http://pdfserv.maxim-ic.com/en/ds/MAX1619.pdf
11 Authors:
12         Oleksij Rempel <bug-track@fisher-privat.net>,
13         Jean Delvare <jdelvare@suse.de>
15 Description
16 -----------
18 The MAX1619 is a digital temperature sensor. It senses its own temperature as
19 well as the temperature of up to one external diode.
21 All temperature values are given in degrees Celsius. Resolution
22 is 1.0 degree for the local temperature and for the remote temperature.
24 Only the external sensor has high and low limits.
26 The max1619 driver will not update its values more frequently than every
27 other second; reading them more often will do no harm, but will return
28 'old' values.