thinkpad-acpi: kill hotkey_thread_mutex
[linux/fpc-iii.git] / drivers / thermal / Kconfig
bloba764f165b58930da5044c208693a86a817bab93f
2 # Generic thermal sysfs drivers configuration
5 menuconfig THERMAL
6         tristate "Generic Thermal sysfs driver"
7         help
8           Generic Thermal Sysfs driver offers a generic mechanism for
9           thermal management. Usually it's made up of one or more thermal
10           zone and cooling device.
11           Each thermal zone contains its own temperature, trip points,
12           cooling devices.
13           All platforms with ACPI thermal support can use this driver.
14           If you want this support, you should say Y or M here.
16 if THERMAL
18 config THERMAL_HWMON
19         bool
20         depends on HWMON=y || HWMON=THERMAL
21         default y
23 choice
24         prompt "Default Thermal governor"
25         default THERMAL_DEFAULT_GOV_STEP_WISE
26         help
27           This option sets which thermal governor shall be loaded at
28           startup. If in doubt, select 'step_wise'.
30 config THERMAL_DEFAULT_GOV_STEP_WISE
31         bool "step_wise"
32         select THERMAL_GOV_STEP_WISE
33         help
34           Use the step_wise governor as default. This throttles the
35           devices one step at a time.
37 config THERMAL_DEFAULT_GOV_FAIR_SHARE
38         bool "fair_share"
39         select THERMAL_GOV_FAIR_SHARE
40         help
41           Use the fair_share governor as default. This throttles the
42           devices based on their 'contribution' to a zone. The
43           contribution should be provided through platform data.
45 config THERMAL_DEFAULT_GOV_USER_SPACE
46         bool "user_space"
47         select THERMAL_GOV_USER_SPACE
48         help
49           Select this if you want to let the user space manage the
50           lpatform thermals.
52 endchoice
54 config THERMAL_GOV_FAIR_SHARE
55         bool "Fair-share thermal governor"
56         help
57           Enable this to manage platform thermals using fair-share governor.
59 config THERMAL_GOV_STEP_WISE
60         bool "Step_wise thermal governor"
61         help
62           Enable this to manage platform thermals using a simple linear
64 config THERMAL_GOV_USER_SPACE
65         bool "User_space thermal governor"
66         help
67           Enable this to let the user space manage the platform thermals.
69 config CPU_THERMAL
70         tristate "generic cpu cooling support"
71         depends on CPU_FREQ
72         select CPU_FREQ_TABLE
73         help
74           This implements the generic cpu cooling mechanism through frequency
75           reduction, cpu hotplug and any other ways of reducing temperature. An
76           ACPI version of this already exists(drivers/acpi/processor_thermal.c).
77           This will be useful for platforms using the generic thermal interface
78           and not the ACPI interface.
79           If you want this support, you should say Y here.
81 config THERMAL_EMULATION
82         bool "Thermal emulation mode support"
83         help
84           Enable this option to make a emul_temp sysfs node in thermal zone
85           directory to support temperature emulation. With emulation sysfs node,
86           user can manually input temperature and test the different trip
87           threshold behaviour for simulation purpose.
89 config SPEAR_THERMAL
90         bool "SPEAr thermal sensor driver"
91         depends on PLAT_SPEAR
92         depends on OF
93         help
94           Enable this to plug the SPEAr thermal sensor driver into the Linux
95           thermal framework
97 config RCAR_THERMAL
98         tristate "Renesas R-Car thermal driver"
99         depends on ARCH_SHMOBILE
100         help
101           Enable this to plug the R-Car thermal sensor driver into the Linux
102           thermal framework
104 config KIRKWOOD_THERMAL
105         tristate "Temperature sensor on Marvell Kirkwood SoCs"
106         depends on ARCH_KIRKWOOD
107         depends on OF
108         help
109           Support for the Kirkwood thermal sensor driver into the Linux thermal
110           framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
112 config EXYNOS_THERMAL
113         tristate "Temperature sensor on Samsung EXYNOS"
114         depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
115         depends on CPU_THERMAL
116         help
117           If you say yes here you get support for TMU (Thermal Management
118           Unit) on SAMSUNG EXYNOS series of SoC.
120 config EXYNOS_THERMAL_EMUL
121         bool "EXYNOS TMU emulation mode support"
122         depends on EXYNOS_THERMAL
123         help
124           Exynos 4412 and 4414 and 5 series has emulation mode on TMU.
125           Enable this option will be make sysfs node in exynos thermal platform
126           device directory to support emulation mode. With emulation mode sysfs
127           node, you can manually input temperature to TMU for simulation purpose.
129 config DOVE_THERMAL
130         tristate "Temperature sensor on Marvell Dove SoCs"
131         depends on ARCH_DOVE
132         depends on OF
133         help
134           Support for the Dove thermal sensor driver in the Linux thermal
135           framework.
137 config DB8500_THERMAL
138         bool "DB8500 thermal management"
139         depends on ARCH_U8500
140         default y
141         help
142           Adds DB8500 thermal management implementation according to the thermal
143           management framework. A thermal zone with several trip points will be
144           created. Cooling devices can be bound to the trip points to cool this
145           thermal zone if trip points reached.
147 config DB8500_CPUFREQ_COOLING
148         tristate "DB8500 cpufreq cooling"
149         depends on ARCH_U8500
150         depends on CPU_THERMAL
151         default y
152         help
153           Adds DB8500 cpufreq cooling devices, and these cooling devices can be
154           bound to thermal zone trip points. When a trip point reached, the
155           bound cpufreq cooling device turns active to set CPU frequency low to
156           cool down the CPU.
158 config INTEL_POWERCLAMP
159         tristate "Intel PowerClamp idle injection driver"
160         depends on THERMAL
161         depends on X86
162         depends on CPU_SUP_INTEL
163         help
164           Enable this to enable Intel PowerClamp idle injection driver. This
165           enforce idle time which results in more package C-state residency. The
166           user interface is exposed via generic thermal framework.
168 endif