video/console: use swap() in newport_bmove()
[linux/fpc-iii.git] / drivers / pci / hotplug / rpadlpar_core.c
blobe12bafdc42e003e3d2c18eb187baf354e0945aa5
1 /*
2 * Interface for Dynamic Logical Partitioning of I/O Slots on
3 * RPA-compliant PPC64 platform.
5 * John Rose <johnrose@austin.ibm.com>
6 * Linda Xie <lxie@us.ibm.com>
8 * October 2003
10 * Copyright (C) 2003 IBM.
12 * This program is free software; you can redistribute it and/or
13 * modify it under the terms of the GNU General Public License
14 * as published by the Free Software Foundation; either version
15 * 2 of the License, or (at your option) any later version.
18 #undef DEBUG
20 #include <linux/init.h>
21 #include <linux/module.h>
22 #include <linux/pci.h>
23 #include <linux/string.h>
24 #include <linux/vmalloc.h>
26 #include <asm/pci-bridge.h>
27 #include <linux/mutex.h>
28 #include <asm/rtas.h>
29 #include <asm/vio.h>
31 #include "../pci.h"
32 #include "rpaphp.h"
33 #include "rpadlpar.h"
35 static DEFINE_MUTEX(rpadlpar_mutex);
37 #define DLPAR_MODULE_NAME "rpadlpar_io"
39 #define NODE_TYPE_VIO 1
40 #define NODE_TYPE_SLOT 2
41 #define NODE_TYPE_PHB 3
43 static struct device_node *find_vio_slot_node(char *drc_name)
45 struct device_node *parent = of_find_node_by_name(NULL, "vdevice");
46 struct device_node *dn = NULL;
47 char *name;
48 int rc;
50 if (!parent)
51 return NULL;
53 while ((dn = of_get_next_child(parent, dn))) {
54 rc = rpaphp_get_drc_props(dn, NULL, &name, NULL, NULL);
55 if ((rc == 0) && (!strcmp(drc_name, name)))
56 break;
59 return dn;
62 /* Find dlpar-capable pci node that contains the specified name and type */
63 static struct device_node *find_php_slot_pci_node(char *drc_name,
64 char *drc_type)
66 struct device_node *np = NULL;
67 char *name;
68 char *type;
69 int rc;
71 while ((np = of_find_node_by_name(np, "pci"))) {
72 rc = rpaphp_get_drc_props(np, NULL, &name, &type, NULL);
73 if (rc == 0)
74 if (!strcmp(drc_name, name) && !strcmp(drc_type, type))
75 break;
78 return np;
81 static struct device_node *find_dlpar_node(char *drc_name, int *node_type)
83 struct device_node *dn;
85 dn = find_php_slot_pci_node(drc_name, "SLOT");
86 if (dn) {
87 *node_type = NODE_TYPE_SLOT;
88 return dn;
91 dn = find_php_slot_pci_node(drc_name, "PHB");
92 if (dn) {
93 *node_type = NODE_TYPE_PHB;
94 return dn;
97 dn = find_vio_slot_node(drc_name);
98 if (dn) {
99 *node_type = NODE_TYPE_VIO;
100 return dn;
103 return NULL;
107 * find_php_slot - return hotplug slot structure for device node
108 * @dn: target &device_node
110 * This routine will return the hotplug slot structure
111 * for a given device node. Note that built-in PCI slots
112 * may be dlpar-able, but not hot-pluggable, so this routine
113 * will return NULL for built-in PCI slots.
115 static struct slot *find_php_slot(struct device_node *dn)
117 struct list_head *tmp, *n;
118 struct slot *slot;
120 list_for_each_safe(tmp, n, &rpaphp_slot_head) {
121 slot = list_entry(tmp, struct slot, rpaphp_slot_list);
122 if (slot->dn == dn)
123 return slot;
126 return NULL;
129 static struct pci_dev *dlpar_find_new_dev(struct pci_bus *parent,
130 struct device_node *dev_dn)
132 struct pci_dev *tmp = NULL;
133 struct device_node *child_dn;
135 list_for_each_entry(tmp, &parent->devices, bus_list) {
136 child_dn = pci_device_to_OF_node(tmp);
137 if (child_dn == dev_dn)
138 return tmp;
140 return NULL;
143 static void dlpar_pci_add_bus(struct device_node *dn)
145 struct pci_dn *pdn = PCI_DN(dn);
146 struct pci_controller *phb = pdn->phb;
147 struct pci_dev *dev = NULL;
149 eeh_add_device_tree_early(pdn);
151 /* Add EADS device to PHB bus, adding new entry to bus->devices */
152 dev = of_create_pci_dev(dn, phb->bus, pdn->devfn);
153 if (!dev) {
154 printk(KERN_ERR "%s: failed to create pci dev for %s\n",
155 __func__, dn->full_name);
156 return;
159 /* Scan below the new bridge */
160 if (pci_is_bridge(dev))
161 of_scan_pci_bridge(dev);
163 /* Map IO space for child bus, which may or may not succeed */
164 pcibios_map_io_space(dev->subordinate);
166 /* Finish adding it : resource allocation, adding devices, etc...
167 * Note that we need to perform the finish pass on the -parent-
168 * bus of the EADS bridge so the bridge device itself gets
169 * properly added
171 pcibios_finish_adding_to_bus(phb->bus);
174 static int dlpar_add_pci_slot(char *drc_name, struct device_node *dn)
176 struct pci_dev *dev;
177 struct pci_controller *phb;
179 if (pcibios_find_pci_bus(dn))
180 return -EINVAL;
182 /* Add pci bus */
183 dlpar_pci_add_bus(dn);
185 /* Confirm new bridge dev was created */
186 phb = PCI_DN(dn)->phb;
187 dev = dlpar_find_new_dev(phb->bus, dn);
189 if (!dev) {
190 printk(KERN_ERR "%s: unable to add bus %s\n", __func__,
191 drc_name);
192 return -EIO;
195 if (dev->hdr_type != PCI_HEADER_TYPE_BRIDGE) {
196 printk(KERN_ERR "%s: unexpected header type %d, unable to add bus %s\n",
197 __func__, dev->hdr_type, drc_name);
198 return -EIO;
201 /* Add hotplug slot */
202 if (rpaphp_add_slot(dn)) {
203 printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
204 __func__, drc_name);
205 return -EIO;
207 return 0;
210 static int dlpar_remove_phb(char *drc_name, struct device_node *dn)
212 struct slot *slot;
213 struct pci_dn *pdn;
214 int rc = 0;
216 if (!pcibios_find_pci_bus(dn))
217 return -EINVAL;
219 /* If pci slot is hotpluggable, use hotplug to remove it */
220 slot = find_php_slot(dn);
221 if (slot && rpaphp_deregister_slot(slot)) {
222 printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",
223 __func__, drc_name);
224 return -EIO;
227 pdn = dn->data;
228 BUG_ON(!pdn || !pdn->phb);
229 rc = remove_phb_dynamic(pdn->phb);
230 if (rc < 0)
231 return rc;
233 pdn->phb = NULL;
235 return 0;
238 static int dlpar_add_phb(char *drc_name, struct device_node *dn)
240 struct pci_controller *phb;
242 if (PCI_DN(dn) && PCI_DN(dn)->phb) {
243 /* PHB already exists */
244 return -EINVAL;
247 phb = init_phb_dynamic(dn);
248 if (!phb)
249 return -EIO;
251 if (rpaphp_add_slot(dn)) {
252 printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
253 __func__, drc_name);
254 return -EIO;
256 return 0;
259 static int dlpar_add_vio_slot(char *drc_name, struct device_node *dn)
261 if (vio_find_node(dn))
262 return -EINVAL;
264 if (!vio_register_device_node(dn)) {
265 printk(KERN_ERR
266 "%s: failed to register vio node %s\n",
267 __func__, drc_name);
268 return -EIO;
270 return 0;
274 * dlpar_add_slot - DLPAR add an I/O Slot
275 * @drc_name: drc-name of newly added slot
277 * Make the hotplug module and the kernel aware of a newly added I/O Slot.
278 * Return Codes:
279 * 0 Success
280 * -ENODEV Not a valid drc_name
281 * -EINVAL Slot already added
282 * -ERESTARTSYS Signalled before obtaining lock
283 * -EIO Internal PCI Error
285 int dlpar_add_slot(char *drc_name)
287 struct device_node *dn = NULL;
288 int node_type;
289 int rc = -EIO;
291 if (mutex_lock_interruptible(&rpadlpar_mutex))
292 return -ERESTARTSYS;
294 /* Find newly added node */
295 dn = find_dlpar_node(drc_name, &node_type);
296 if (!dn) {
297 rc = -ENODEV;
298 goto exit;
301 switch (node_type) {
302 case NODE_TYPE_VIO:
303 rc = dlpar_add_vio_slot(drc_name, dn);
304 break;
305 case NODE_TYPE_SLOT:
306 rc = dlpar_add_pci_slot(drc_name, dn);
307 break;
308 case NODE_TYPE_PHB:
309 rc = dlpar_add_phb(drc_name, dn);
310 break;
313 printk(KERN_INFO "%s: slot %s added\n", DLPAR_MODULE_NAME, drc_name);
314 exit:
315 mutex_unlock(&rpadlpar_mutex);
316 return rc;
320 * dlpar_remove_vio_slot - DLPAR remove a virtual I/O Slot
321 * @drc_name: drc-name of newly added slot
322 * @dn: &device_node
324 * Remove the kernel and hotplug representations of an I/O Slot.
325 * Return Codes:
326 * 0 Success
327 * -EINVAL Vio dev doesn't exist
329 static int dlpar_remove_vio_slot(char *drc_name, struct device_node *dn)
331 struct vio_dev *vio_dev;
333 vio_dev = vio_find_node(dn);
334 if (!vio_dev)
335 return -EINVAL;
337 vio_unregister_device(vio_dev);
338 return 0;
342 * dlpar_remove_pci_slot - DLPAR remove a PCI I/O Slot
343 * @drc_name: drc-name of newly added slot
344 * @dn: &device_node
346 * Remove the kernel and hotplug representations of a PCI I/O Slot.
347 * Return Codes:
348 * 0 Success
349 * -ENODEV Not a valid drc_name
350 * -EIO Internal PCI Error
352 int dlpar_remove_pci_slot(char *drc_name, struct device_node *dn)
354 struct pci_bus *bus;
355 struct slot *slot;
356 int ret = 0;
358 pci_lock_rescan_remove();
360 bus = pcibios_find_pci_bus(dn);
361 if (!bus) {
362 ret = -EINVAL;
363 goto out;
366 pr_debug("PCI: Removing PCI slot below EADS bridge %s\n",
367 bus->self ? pci_name(bus->self) : "<!PHB!>");
369 slot = find_php_slot(dn);
370 if (slot) {
371 pr_debug("PCI: Removing hotplug slot for %04x:%02x...\n",
372 pci_domain_nr(bus), bus->number);
374 if (rpaphp_deregister_slot(slot)) {
375 printk(KERN_ERR
376 "%s: unable to remove hotplug slot %s\n",
377 __func__, drc_name);
378 ret = -EIO;
379 goto out;
383 /* Remove all devices below slot */
384 pcibios_remove_pci_devices(bus);
386 /* Unmap PCI IO space */
387 if (pcibios_unmap_io_space(bus)) {
388 printk(KERN_ERR "%s: failed to unmap bus range\n",
389 __func__);
390 ret = -ERANGE;
391 goto out;
394 /* Remove the EADS bridge device itself */
395 BUG_ON(!bus->self);
396 pr_debug("PCI: Now removing bridge device %s\n", pci_name(bus->self));
397 pci_stop_and_remove_bus_device(bus->self);
399 out:
400 pci_unlock_rescan_remove();
401 return ret;
405 * dlpar_remove_slot - DLPAR remove an I/O Slot
406 * @drc_name: drc-name of newly added slot
408 * Remove the kernel and hotplug representations of an I/O Slot.
409 * Return Codes:
410 * 0 Success
411 * -ENODEV Not a valid drc_name
412 * -EINVAL Slot already removed
413 * -ERESTARTSYS Signalled before obtaining lock
414 * -EIO Internal Error
416 int dlpar_remove_slot(char *drc_name)
418 struct device_node *dn;
419 int node_type;
420 int rc = 0;
422 if (mutex_lock_interruptible(&rpadlpar_mutex))
423 return -ERESTARTSYS;
425 dn = find_dlpar_node(drc_name, &node_type);
426 if (!dn) {
427 rc = -ENODEV;
428 goto exit;
431 switch (node_type) {
432 case NODE_TYPE_VIO:
433 rc = dlpar_remove_vio_slot(drc_name, dn);
434 break;
435 case NODE_TYPE_PHB:
436 rc = dlpar_remove_phb(drc_name, dn);
437 break;
438 case NODE_TYPE_SLOT:
439 rc = dlpar_remove_pci_slot(drc_name, dn);
440 break;
442 vm_unmap_aliases();
444 printk(KERN_INFO "%s: slot %s removed\n", DLPAR_MODULE_NAME, drc_name);
445 exit:
446 mutex_unlock(&rpadlpar_mutex);
447 return rc;
450 static inline int is_dlpar_capable(void)
452 int rc = rtas_token("ibm,configure-connector");
454 return (int) (rc != RTAS_UNKNOWN_SERVICE);
457 int __init rpadlpar_io_init(void)
459 int rc = 0;
461 if (!is_dlpar_capable()) {
462 printk(KERN_WARNING "%s: partition not DLPAR capable\n",
463 __func__);
464 return -EPERM;
467 rc = dlpar_sysfs_init();
468 return rc;
471 void rpadlpar_io_exit(void)
473 dlpar_sysfs_exit();
474 return;
477 module_init(rpadlpar_io_init);
478 module_exit(rpadlpar_io_exit);
479 MODULE_LICENSE("GPL");