Linux 4.11-rc6
[linux/fpc-iii.git] / Documentation / hwmon / lm73
blob8af059dcb64239c180040cb0dac450df89748422
1 Kernel driver lm73
2 ==================
4 Supported chips:
5   * Texas Instruments LM73
6     Prefix: 'lm73'
7     Addresses scanned: I2C 0x48, 0x49, 0x4a, 0x4c, 0x4d, and 0x4e
8     Datasheet: Publicly available at the Texas Instruments website
9                http://www.ti.com/product/lm73
11 Author: Guillaume Ligneul <guillaume.ligneul@gmail.com>
12 Documentation: Chris Verges <kg4ysn@gmail.com>
15 Description
16 -----------
18 The LM73 is a digital temperature sensor.  All temperature values are
19 given in degrees Celsius.
21 Measurement Resolution Support
22 ------------------------------
24 The LM73 supports four resolutions, defined in terms of degrees C per
25 LSB: 0.25, 0.125, 0.0625, and 0.3125.  Changing the resolution mode
26 affects the conversion time of the LM73's analog-to-digital converter.
27 From userspace, the desired resolution can be specified as a function of
28 conversion time via the 'update_interval' sysfs attribute for the
29 device.  This attribute will normalize ranges of input values to the
30 maximum times defined for the resolution in the datasheet.
32     Resolution    Conv. Time    Input Range
33     (C/LSB)       (msec)        (msec)
34     --------------------------------------
35     0.25          14             0..14
36     0.125         28            15..28
37     0.0625        56            29..56
38     0.03125       112           57..infinity
39     --------------------------------------
41 The following examples show how the 'update_interval' attribute can be
42 used to change the conversion time:
44     $ echo 0 > update_interval
45     $ cat update_interval
46     14
47     $ cat temp1_input
48     24250
50     $ echo 22 > update_interval
51     $ cat update_interval
52     28
53     $ cat temp1_input
54     24125
56     $ echo 56 > update_interval
57     $ cat update_interval
58     56
59     $ cat temp1_input
60     24062
62     $ echo 85 > update_interval
63     $ cat update_interval
64     112
65     $ cat temp1_input
66     24031
68 As shown here, the lm73 driver automatically adjusts any user input for
69 'update_interval' via a step function.  Reading back the
70 'update_interval' value after a write operation will confirm the
71 conversion time actively in use.
73 Mathematically, the resolution can be derived from the conversion time
74 via the following function:
76    g(x) = 0.250 * [log(x/14) / log(2)]
78 where 'x' is the output from 'update_interval' and 'g(x)' is the
79 resolution in degrees C per LSB.
81 Alarm Support
82 -------------
84 The LM73 features a simple over-temperature alarm mechanism.  This
85 feature is exposed via the sysfs attributes.
87 The attributes 'temp1_max_alarm' and 'temp1_min_alarm' are flags
88 provided by the LM73 that indicate whether the measured temperature has
89 passed the 'temp1_max' and 'temp1_min' thresholds, respectively.  These
90 values _must_ be read to clear the registers on the LM73.