Linux 4.11-rc6
[linux/fpc-iii.git] / Documentation / leds / leds-mlxcpld.txt
bloba0e8fd45711791c21a3efe6f4e823f5ad50a2e83
1 Kernel driver for Mellanox systems LEDs
2 =======================================
4 Provide system LED support for the nex Mellanox systems:
5 "msx6710", "msx6720", "msb7700", "msn2700", "msx1410",
6 "msn2410", "msb7800", "msn2740", "msn2100".
8 Description
9 -----------
10 Driver provides the following LEDs for the systems "msx6710", "msx6720",
11 "msb7700", "msn2700", "msx1410", "msn2410", "msb7800", "msn2740":
12   mlxcpld:fan1:green
13   mlxcpld:fan1:red
14   mlxcpld:fan2:green
15   mlxcpld:fan2:red
16   mlxcpld:fan3:green
17   mlxcpld:fan3:red
18   mlxcpld:fan4:green
19   mlxcpld:fan4:red
20   mlxcpld:psu:green
21   mlxcpld:psu:red
22   mlxcpld:status:green
23   mlxcpld:status:red
25  "status"
26   CPLD reg offset: 0x20
27   Bits [3:0]
29  "psu"
30   CPLD reg offset: 0x20
31   Bits [7:4]
33  "fan1"
34   CPLD reg offset: 0x21
35   Bits [3:0]
37  "fan2"
38   CPLD reg offset: 0x21
39   Bits [7:4]
41  "fan3"
42   CPLD reg offset: 0x22
43   Bits [3:0]
45  "fan4"
46   CPLD reg offset: 0x22
47   Bits [7:4]
49  Color mask for all the above LEDs:
50   [bit3,bit2,bit1,bit0] or
51   [bit7,bit6,bit5,bit4]:
52         [0,0,0,0] = LED OFF
53         [0,1,0,1] = Red static ON
54         [1,1,0,1] = Green static ON
55         [0,1,1,0] = Red blink 3Hz
56         [1,1,1,0] = Green blink 3Hz
57         [0,1,1,1] = Red blink 6Hz
58         [1,1,1,1] = Green blink 6Hz
60 Driver provides the following LEDs for the system "msn2100":
61   mlxcpld:fan:green
62   mlxcpld:fan:red
63   mlxcpld:psu1:green
64   mlxcpld:psu1:red
65   mlxcpld:psu2:green
66   mlxcpld:psu2:red
67   mlxcpld:status:green
68   mlxcpld:status:red
69   mlxcpld:uid:blue
71  "status"
72   CPLD reg offset: 0x20
73   Bits [3:0]
75  "fan"
76   CPLD reg offset: 0x21
77   Bits [3:0]
79  "psu1"
80   CPLD reg offset: 0x23
81   Bits [3:0]
83  "psu2"
84   CPLD reg offset: 0x23
85   Bits [7:4]
87  "uid"
88   CPLD reg offset: 0x24
89   Bits [3:0]
91  Color mask for all the above LEDs, excepted uid:
92   [bit3,bit2,bit1,bit0] or
93   [bit7,bit6,bit5,bit4]:
94         [0,0,0,0] = LED OFF
95         [0,1,0,1] = Red static ON
96         [1,1,0,1] = Green static ON
97         [0,1,1,0] = Red blink 3Hz
98         [1,1,1,0] = Green blink 3Hz
99         [0,1,1,1] = Red blink 6Hz
100         [1,1,1,1] = Green blink 6Hz
102  Color mask for uid LED:
103   [bit3,bit2,bit1,bit0]:
104         [0,0,0,0] = LED OFF
105         [1,1,0,1] = Blue static ON
106         [1,1,1,0] = Blue blink 3Hz
107         [1,1,1,1] = Blue blink 6Hz
109 Driver supports HW blinking at 3Hz and 6Hz frequency (50% duty cycle).
110 For 3Hz duty cylce is about 167 msec, for 6Hz is about 83 msec.