1 What: /sys/bus/counter/devices/counterX/signalY/index_polarity
3 Contact: linux-iio@vger.kernel.org
5 Active level of index input Signal Y; irrelevant in
6 non-synchronous load mode.
8 What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
9 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
11 Contact: linux-iio@vger.kernel.org
13 Discrete set of available values for the respective Signal Y
14 configuration are listed in this file.
16 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
18 Contact: linux-iio@vger.kernel.org
20 Configure the counter associated with Signal Y for
21 non-synchronous or synchronous load mode. Synchronous load mode
22 cannot be selected in non-quadrature (Pulse-Direction) clock
26 A logic low level is the active level at this index
27 input. The index function (as enabled via preset_enable)
28 is performed directly on the active level of the index
32 Intended for interfacing with encoder Index output in
33 quadrature clock mode. The active level is configured
34 via index_polarity. The index function (as enabled via
35 preset_enable) is performed synchronously with the
36 quadrature clock on the active level of the index input.