1 What: /sys/bus/platform/devices/dfl-fme.0/ports_num
4 Contact: Wu Hao <hao.wu@intel.com>
5 Description: Read-only. One DFL FPGA device may have more than 1
6 port/Accelerator Function Unit (AFU). It returns the
7 number of ports on the FPGA device when read it.
9 What: /sys/bus/platform/devices/dfl-fme.0/bitstream_id
12 Contact: Wu Hao <hao.wu@intel.com>
13 Description: Read-only. It returns Bitstream (static FPGA region)
14 identifier number, which includes the detailed version
15 and other information of this static FPGA region.
17 What: /sys/bus/platform/devices/dfl-fme.0/bitstream_metadata
20 Contact: Wu Hao <hao.wu@intel.com>
21 Description: Read-only. It returns Bitstream (static FPGA region) meta
22 data, which includes the synthesis date, seed and other
23 information of this static FPGA region.
25 What: /sys/bus/platform/devices/dfl-fme.0/cache_size
28 Contact: Wu Hao <hao.wu@intel.com>
29 Description: Read-only. It returns cache size of this FPGA device.
31 What: /sys/bus/platform/devices/dfl-fme.0/fabric_version
34 Contact: Wu Hao <hao.wu@intel.com>
35 Description: Read-only. It returns fabric version of this FPGA device.
36 Userspace applications need this information to select
37 best data channels per different fabric design.
39 What: /sys/bus/platform/devices/dfl-fme.0/socket_id
42 Contact: Wu Hao <hao.wu@intel.com>
43 Description: Read-only. It returns socket_id to indicate which socket
44 this FPGA belongs to, only valid for integrated solution.
45 User only needs this information, in case standard numa node
46 can't provide correct information.
48 What: /sys/bus/platform/devices/dfl-fme.0/errors/pcie0_errors
51 Contact: Wu Hao <hao.wu@intel.com>
52 Description: Read-Write. Read this file for errors detected on pcie0 link.
53 Write this file to clear errors logged in pcie0_errors. Write
54 fails with -EINVAL if input parsing fails or input error code
57 What: /sys/bus/platform/devices/dfl-fme.0/errors/pcie1_errors
60 Contact: Wu Hao <hao.wu@intel.com>
61 Description: Read-Write. Read this file for errors detected on pcie1 link.
62 Write this file to clear errors logged in pcie1_errors. Write
63 fails with -EINVAL if input parsing fails or input error code
66 What: /sys/bus/platform/devices/dfl-fme.0/errors/nonfatal_errors
69 Contact: Wu Hao <hao.wu@intel.com>
70 Description: Read-only. It returns non-fatal errors detected.
72 What: /sys/bus/platform/devices/dfl-fme.0/errors/catfatal_errors
75 Contact: Wu Hao <hao.wu@intel.com>
76 Description: Read-only. It returns catastrophic and fatal errors detected.
78 What: /sys/bus/platform/devices/dfl-fme.0/errors/inject_errors
81 Contact: Wu Hao <hao.wu@intel.com>
82 Description: Read-Write. Read this file to check errors injected. Write this
83 file to inject errors for testing purpose. Write fails with
84 -EINVAL if input parsing fails or input inject error code isn't
87 What: /sys/bus/platform/devices/dfl-fme.0/errors/fme_errors
90 Contact: Wu Hao <hao.wu@intel.com>
91 Description: Read-Write. Read this file to get errors detected on FME.
92 Write this file to clear errors logged in fme_errors. Write
93 fials with -EINVAL if input parsing fails or input error code
96 What: /sys/bus/platform/devices/dfl-fme.0/errors/first_error
99 Contact: Wu Hao <hao.wu@intel.com>
100 Description: Read-only. Read this file to get the first error detected by
103 What: /sys/bus/platform/devices/dfl-fme.0/errors/next_error
106 Contact: Wu Hao <hao.wu@intel.com>
107 Description: Read-only. Read this file to get the second error detected by
110 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/name
113 Contact: Wu Hao <hao.wu@intel.com>
114 Description: Read-Only. Read this file to get the name of hwmon device, it
116 'dfl_fme_thermal' - thermal hwmon device name
117 'dfl_fme_power' - power hwmon device name
119 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_input
122 Contact: Wu Hao <hao.wu@intel.com>
123 Description: Read-Only. It returns FPGA device temperature in millidegrees
126 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max
129 Contact: Wu Hao <hao.wu@intel.com>
130 Description: Read-Only. It returns hardware threshold1 temperature in
131 millidegrees Celsius. If temperature rises at or above this
132 threshold, hardware starts 50% or 90% throttling (see
135 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_crit
138 Contact: Wu Hao <hao.wu@intel.com>
139 Description: Read-Only. It returns hardware threshold2 temperature in
140 millidegrees Celsius. If temperature rises at or above this
141 threshold, hardware starts 100% throttling.
143 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_emergency
146 Contact: Wu Hao <hao.wu@intel.com>
147 Description: Read-Only. It returns hardware trip threshold temperature in
148 millidegrees Celsius. If temperature rises at or above this
149 threshold, a fatal event will be triggered to board management
150 controller (BMC) to shutdown FPGA.
152 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max_alarm
155 Contact: Wu Hao <hao.wu@intel.com>
156 Description: Read-only. It returns 1 if temperature is currently at or above
157 hardware threshold1 (see 'temp1_max'), otherwise 0.
159 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_crit_alarm
162 Contact: Wu Hao <hao.wu@intel.com>
163 Description: Read-only. It returns 1 if temperature is currently at or above
164 hardware threshold2 (see 'temp1_crit'), otherwise 0.
166 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max_policy
169 Contact: Wu Hao <hao.wu@intel.com>
170 Description: Read-Only. Read this file to get the policy of hardware threshold1
171 (see 'temp1_max'). It only supports two values (policies):
172 0 - AP2 state (90% throttling)
173 1 - AP1 state (50% throttling)
175 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_input
178 Contact: Wu Hao <hao.wu@intel.com>
179 Description: Read-Only. It returns current FPGA power consumption in uW.
181 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_max
184 Contact: Wu Hao <hao.wu@intel.com>
185 Description: Read-Write. Read this file to get current hardware power
186 threshold1 in uW. If power consumption rises at or above
187 this threshold, hardware starts 50% throttling.
188 Write this file to set current hardware power threshold1 in uW.
189 As hardware only accepts values in Watts, so input value will
190 be round down per Watts (< 1 watts part will be discarded) and
191 clamped within the range from 0 to 127 Watts. Write fails with
192 -EINVAL if input parsing fails.
194 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_crit
197 Contact: Wu Hao <hao.wu@intel.com>
198 Description: Read-Write. Read this file to get current hardware power
199 threshold2 in uW. If power consumption rises at or above
200 this threshold, hardware starts 90% throttling.
201 Write this file to set current hardware power threshold2 in uW.
202 As hardware only accepts values in Watts, so input value will
203 be round down per Watts (< 1 watts part will be discarded) and
204 clamped within the range from 0 to 127 Watts. Write fails with
205 -EINVAL if input parsing fails.
207 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_max_alarm
210 Contact: Wu Hao <hao.wu@intel.com>
211 Description: Read-only. It returns 1 if power consumption is currently at or
212 above hardware threshold1 (see 'power1_max'), otherwise 0.
214 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_crit_alarm
217 Contact: Wu Hao <hao.wu@intel.com>
218 Description: Read-only. It returns 1 if power consumption is currently at or
219 above hardware threshold2 (see 'power1_crit'), otherwise 0.
221 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_xeon_limit
224 Contact: Wu Hao <hao.wu@intel.com>
225 Description: Read-Only. It returns power limit for XEON in uW.
227 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_fpga_limit
230 Contact: Wu Hao <hao.wu@intel.com>
231 Description: Read-Only. It returns power limit for FPGA in uW.
233 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_ltr
236 Contact: Wu Hao <hao.wu@intel.com>
237 Description: Read-only. Read this file to get current Latency Tolerance
238 Reporting (ltr) value. It returns 1 if all Accelerated
239 Function Units (AFUs) can tolerate latency >= 40us for memory
240 access or 0 if any AFU is latency sensitive (< 40us).