1 BOE HV070WSA-100 7.01" WSVGA TFT LCD panel
3 Required properties:
4 - compatible: should be "boe,hv070wsa-100"
5 - power-supply: regulator to provide the VCC supply voltage (3.3 volts)
6 - enable-gpios: GPIO pin to enable and disable panel (active high)
8 This binding is compatible with the simple-panel binding, which is specified
9 in simple-panel.txt in this directory.
11 The device node can contain one 'port' child node with one child
12 'endpoint' node, according to the bindings defined in [1]. This
13 node should describe panel's video bus.
15 [1]: Documentation/devicetree/bindings/media/video-interfaces.txt
17 Example:
19         panel: panel {
20                 compatible = "boe,hv070wsa-100";
21                 power-supply = <&vcc_3v3_reg>;
22                 enable-gpios = <&gpd1 3 GPIO_ACTIVE_HIGH>;
23                 port {
24                         panel_ep: endpoint {
25                                 remote-endpoint = <&bridge_out_ep>;
26                         };
27                 };
28         };