treewide: remove redundant IS_ERR() before error code check
[linux/fpc-iii.git] / Documentation / hwmon / asb100.rst
blobc2d5f97085fe4658d905b9e86c3a9c7838cd5ece
1 Kernel driver asb100
2 ====================
4 Supported Chips:
6   * Asus ASB100 and ASB100-A "Bach"
8     Prefix: 'asb100'
10     Addresses scanned: I2C 0x2d
12     Datasheet: none released
14 Author: Mark M. Hoffman <mhoffman@lightlink.com>
16 Description
17 -----------
19 This driver implements support for the Asus ASB100 and ASB100-A "Bach".
20 These are custom ASICs available only on Asus mainboards. Asus refuses to
21 supply a datasheet for these chips. Thanks go to many people who helped
22 investigate their hardware, including:
24 Vitaly V. Bursov
25 Alexander van Kaam (author of MBM for Windows)
26 Bertrik Sikken
28 The ASB100 implements seven voltage sensors, three fan rotation speed
29 sensors, four temperature sensors, VID lines and alarms. In addition to
30 these, the ASB100-A also implements a single PWM controller for fans 2 and
31 3 (i.e. one setting controls both.) If you have a plain ASB100, the PWM
32 controller will simply not work (or maybe it will for you... it doesn't for
33 me).
35 Temperatures are measured and reported in degrees Celsius.
37 Fan speeds are reported in RPM (rotations per minute). An alarm is
38 triggered if the rotation speed has dropped below a programmable limit.
40 Voltage sensors (also known as IN sensors) report values in volts.
42 The VID lines encode the core voltage value: the voltage level your
43 processor should work with. This is hardcoded by the mainboard and/or
44 processor itself. It is a value in volts.
46 Alarms: (TODO question marks indicate may or may not work)
48 - 0x0001 => in0 (?)
49 - 0x0002 => in1 (?)
50 - 0x0004 => in2
51 - 0x0008 => in3
52 - 0x0010 => temp1 [1]_
53 - 0x0020 => temp2
54 - 0x0040 => fan1
55 - 0x0080 => fan2
56 - 0x0100 => in4
57 - 0x0200 => in5 (?) [2]_
58 - 0x0400 => in6 (?) [2]_
59 - 0x0800 => fan3
60 - 0x1000 => chassis switch
61 - 0x2000 => temp3
63 .. [1]  This alarm will only trigger if the hysteresis value is 127C.
64         I.e. it behaves the same as w83781d.
66 .. [2]  The min and max registers for these values appear to
67         be read-only or otherwise stuck at 0x00.
69 TODO:
70   * Experiment with fan divisors > 8.
71   * Experiment with temp. sensor types.
72   * Are there really 13 voltage inputs? Probably not...
73   * Cleanups, no doubt...