treewide: remove redundant IS_ERR() before error code check
[linux/fpc-iii.git] / Documentation / hwmon / tmp108.rst
blob5f4266a16cb2e9b27dc7d7d77da7235ed240aee5
1 Kernel driver tmp108
2 ====================
4 Supported chips:
6   * Texas Instruments TMP108
8     Prefix: 'tmp108'
10     Addresses scanned: none
12     Datasheet: http://www.ti.com/product/tmp108
14 Author:
16         John Muir <john@jmuir.com>
18 Description
19 -----------
21 The Texas Instruments TMP108 implements one temperature sensor. An alert pin
22 can be set when temperatures exceed minimum or maximum values plus or minus a
23 hysteresis value. (This driver does not support interrupts for the alert pin,
24 and the device runs in comparator mode.)
26 The sensor is accurate to 0.75C over the range of -25 to +85 C, and to 1.0
27 degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
28 operating temperature has a minimum of -55 C and a maximum of +150 C.
29 Hysteresis values can be set to 0, 1, 2, or 4C.
31 The TMP108 has a programmable update rate that can select between 8, 4, 1, and
32 0.5 Hz.
34 By default the TMP108 reads the temperature continuously. To conserve power,
35 the TMP108 has a one-shot mode where the device is normally shut-down. When a
36 one shot is requested the temperature is read, the result can be retrieved,
37 and then the device is shut down automatically. (This driver only supports
38 continuous mode.)
40 The driver provides the common sysfs-interface for temperatures (see
41 Documentation/hwmon/sysfs-interface.rst under Temperatures).