qlcnic: Fix mailbox completion handling during spurious interrupt
[linux/fpc-iii.git] / Documentation / hwmon / ntc_thermistor
blobc5e05e2900a3250ed7f0884c15a82d72154bf65e
1 Kernel driver ntc_thermistor
2 =================
4 Supported thermistors from Murata:
5 * Murata NTC Thermistors NCP15WB473, NCP18WB473, NCP21WB473, NCP03WB473, NCP15WL333
6   Prefixes: 'ncp15wb473', 'ncp18wb473', 'ncp21wb473', 'ncp03wb473', 'ncp15wl333'
7   Datasheet: Publicly available at Murata
9 Supported thermistors from EPCOS:
10 * EPCOS NTC Thermistors B57330V2103
11   Prefixes: b57330v2103
12   Datasheet: Publicly available at EPCOS
14 Other NTC thermistors can be supported simply by adding compensation
15 tables; e.g., NCP15WL333 support is added by the table ncpXXwl333.
17 Authors:
18         MyungJoo Ham <myungjoo.ham@samsung.com>
20 Description
21 -----------
23 The NTC (Negative Temperature Coefficient) thermistor is a simple thermistor
24 that requires users to provide the resistance and lookup the corresponding
25 compensation table to get the temperature input.
27 The NTC driver provides lookup tables with a linear approximation function
28 and four circuit models with an option not to use any of the four models.
30 The four circuit models provided are:
32         $: resister, [TH]: the thermistor
34  1. connect = NTC_CONNECTED_POSITIVE, pullup_ohm > 0
36    [pullup_uV]
37        |    |
38       [TH]  $ (pullup_ohm)
39        |    |
40        +----+-----------------------[read_uV]
41        |
42        $ (pulldown_ohm)
43        |
44       --- (ground)
46  2. connect = NTC_CONNECTED_POSITIVE, pullup_ohm = 0 (not-connected)
48    [pullup_uV]
49        |
50       [TH]
51        |
52        +----------------------------[read_uV]
53        |
54        $ (pulldown_ohm)
55        |
56       --- (ground)
58  3. connect = NTC_CONNECTED_GROUND, pulldown_ohm > 0
60    [pullup_uV]
61        |
62        $ (pullup_ohm)
63        |
64        +----+-----------------------[read_uV]
65        |    |
66       [TH]  $ (pulldown_ohm)
67        |    |
68       -------- (ground)
70  4. connect = NTC_CONNECTED_GROUND, pulldown_ohm = 0 (not-connected)
72    [pullup_uV]
73        |
74        $ (pullup_ohm)
75        |
76        +----------------------------[read_uV]
77        |
78       [TH]
79        |
80       --- (ground)
82 When one of the four circuit models is used, read_uV, pullup_uV, pullup_ohm,
83 pulldown_ohm, and connect should be provided. When none of the four models
84 are suitable or the user can get the resistance directly, the user should
85 provide read_ohm and _not_ provide the others.
87 Sysfs Interface
88 ---------------
89 name            the mandatory global attribute, the thermistor name.
91 temp1_type      always 4 (thermistor)
92                 RO
94 temp1_input     measure the temperature and provide the measured value.
95                 (reading this file initiates the reading procedure.)
96                 RO
98 Note that each NTC thermistor has only _one_ thermistor; thus, only temp1 exists.