1 USB 7-Segment Numeric Display
2 Manufactured by Delcom Engineering
4 Device Information
5 ------------------
6 USB VENDOR_ID   0x0fc5
7 USB PRODUCT_ID  0x1227
8 Both the 6 character and 8 character displays have PRODUCT_ID,
9 and according to Delcom Engineering no queryable information
10 can be obtained from the device to tell them apart.
12 Device Modes
13 ------------
14 By default, the driver assumes the display is only 6 characters
15 The mode for 6 characters is:
16         MSB 0x06; LSB 0x3f
17 For the 8 character display:
18         MSB 0x08; LSB 0xff
19 The device can accept "text" either in raw, hex, or ascii textmode.
20 raw controls each segment manually,
21 hex expects a value between 0-15 per character,
22 ascii expects a value between '0'-'9' and 'A'-'F'.
23 The default is ascii.
25 Device Operation
26 ----------------
27 1.      Turn on the device:
28         echo 1 > /sys/bus/usb/.../powered
29 2.      Set the device's mode:
30         echo $mode_msb > /sys/bus/usb/.../mode_msb
31         echo $mode_lsb > /sys/bus/usb/.../mode_lsb
32 3.      Set the textmode:
33         echo $textmode > /sys/bus/usb/.../textmode
34 4.      set the text (for example):
35         echo "123ABC" > /sys/bus/usb/.../text (ascii)
36         echo "A1B2" > /sys/bus/usb/.../text (ascii)
37         echo -ne "\x01\x02\x03" > /sys/bus/usb/.../text (hex)
38 5.      Set the decimal places.
39         The device has either 6 or 8 decimal points.
40         to set the nth decimal place calculate 10 ** n
41         and echo it in to /sys/bus/usb/.../decimals
42         To set multiple decimals points sum up each power.
43         For example, to set the 0th and 3rd decimal place
44         echo 1001 > /sys/bus/usb/.../decimals