IB/srp: Let srp_abort() return FAST_IO_FAIL if TL offline
[linux/fpc-iii.git] / Documentation / devicetree / bindings / mtd / gpmc-nor.txt
blob420b3ab18890159614ca9b1413879f4d32c50892
1 Device tree bindings for NOR flash connect to TI GPMC
3 NOR flash connected to the TI GPMC (found on OMAP boards) are represented as
4 child nodes of the GPMC controller with a name of "nor".
6 All timing relevant properties as well as generic GPMC child properties are
7 explained in a separate documents. Please refer to
8 Documentation/devicetree/bindings/bus/ti-gpmc.txt
10 Required properties:
11 - bank-width:           Width of NOR flash in bytes. GPMC supports 8-bit and
12                         16-bit devices and so must be either 1 or 2 bytes.
13 - compatible:           Documentation/devicetree/bindings/mtd/mtd-physmap.txt
14 - gpmc,cs-on-ns:                Chip-select assertion time
15 - gpmc,cs-rd-off-ns:    Chip-select de-assertion time for reads
16 - gpmc,cs-wr-off-ns:    Chip-select de-assertion time for writes
17 - gpmc,oe-on-ns:        Output-enable assertion time
18 - gpmc,oe-off-ns:       Output-enable de-assertion time
19 - gpmc,we-on-ns         Write-enable assertion time
20 - gpmc,we-off-ns:       Write-enable de-assertion time
21 - gpmc,access-ns:       Start cycle to first data capture (read access)
22 - gpmc,rd-cycle-ns:     Total read cycle time
23 - gpmc,wr-cycle-ns:     Total write cycle time
24 - linux,mtd-name:       Documentation/devicetree/bindings/mtd/mtd-physmap.txt
25 - reg:                  Chip-select, base address (relative to chip-select)
26                         and size of NOR flash. Note that base address will be
27                         typically 0 as this is the start of the chip-select.
29 Optional properties:
30 - gpmc,XXX              Additional GPMC timings and settings parameters. See
31                         Documentation/devicetree/bindings/bus/ti-gpmc.txt
33 Optional properties for partiton table parsing:
34 - #address-cells: should be set to 1
35 - #size-cells: should be set to 1
37 Example:
39 gpmc: gpmc@6e000000 {
40         compatible = "ti,omap3430-gpmc", "simple-bus";
41         ti,hwmods = "gpmc";
42         reg = <0x6e000000 0x1000>;
43         interrupts = <20>;
44         gpmc,num-cs = <8>;
45         gpmc,num-waitpins = <4>;
46         #address-cells = <2>;
47         #size-cells = <1>;
49         ranges = <0 0 0x10000000 0x08000000>;
51         nor@0,0 {
52                 compatible = "cfi-flash";
53                 linux,mtd-name= "intel,pf48f6000m0y1be";
54                 #address-cells = <1>;
55                 #size-cells = <1>;
56                 reg = <0 0 0x08000000>;
57                 bank-width = <2>;
59                 gpmc,mux-add-data;
60                 gpmc,cs-on-ns = <0>;
61                 gpmc,cs-rd-off-ns = <186>;
62                 gpmc,cs-wr-off-ns = <186>;
63                 gpmc,adv-on-ns = <12>;
64                 gpmc,adv-rd-off-ns = <48>;
65                 gpmc,adv-wr-off-ns = <48>;
66                 gpmc,oe-on-ns = <54>;
67                 gpmc,oe-off-ns = <168>;
68                 gpmc,we-on-ns = <54>;
69                 gpmc,we-off-ns = <168>;
70                 gpmc,rd-cycle-ns = <186>;
71                 gpmc,wr-cycle-ns = <186>;
72                 gpmc,access-ns = <114>;
73                 gpmc,page-burst-access-ns = <6>;
74                 gpmc,bus-turnaround-ns = <12>;
75                 gpmc,cycle2cycle-delay-ns = <18>;
76                 gpmc,wr-data-mux-bus-ns = <90>;
77                 gpmc,wr-access-ns = <186>;
78                 gpmc,cycle2cycle-samecsen;
79                 gpmc,cycle2cycle-diffcsen;
81                 partition@0 {
82                         label = "bootloader-nor";
83                         reg = <0 0x40000>;
84                 };
85                 partition@0x40000 {
86                         label = "params-nor";
87                         reg = <0x40000 0x40000>;
88                 };
89                 partition@0x80000 {
90                         label = "kernel-nor";
91                         reg = <0x80000 0x200000>;
92                 };
93                 partition@0x280000 {
94                         label = "filesystem-nor";
95                         reg = <0x240000 0x7d80000>;
96                 };
97         };