sh_eth: fix EESIPR values for SH77{34|63}
[linux/fpc-iii.git] / Documentation / i2c / busses / i2c-mlxcpld
blob4e46c440b38d9a07046f43323cc011fcffa10838
1 Driver i2c-mlxcpld
3 Author: Michael Shych <michaelsh@mellanox.com>
5 This is the Mellanox I2C controller logic, implemented in Lattice CPLD
6 device.
7 Device supports:
8  - Master mode.
9  - One physical bus.
10  - Polling mode.
12 This controller is equipped within the next Mellanox systems:
13 "msx6710", "msx6720", "msb7700", "msn2700", "msx1410", "msn2410", "msb7800",
14 "msn2740", "msn2100".
16 The next transaction types are supported:
17  - Receive Byte/Block.
18  - Send Byte/Block.
19  - Read Byte/Block.
20  - Write Byte/Block.
22 Registers:
23 CTRL            0x1 - control reg.
24                         Resets all the registers.
25 HALF_CYC        0x4 - cycle reg.
26                         Configure the width of I2C SCL half clock cycle (in 4 LPC_CLK
27                         units).
28 I2C_HOLD        0x5 - hold reg.
29                         OE (output enable) is delayed by value set to this register
30                         (in LPC_CLK units)
31 CMD                     0x6 - command reg.
32                         Bit 0, 0 = write, 1 = read.
33                         Bits [7:1] - the 7bit Address of the I2C device.
34                         It should be written last as it triggers an I2C transaction.
35 NUM_DATA        0x7 - data size reg.
36                         Number of data bytes to write in read transaction
37 NUM_ADDR        0x8 - address reg.
38                         Number of address bytes to write in read transaction.
39 STATUS          0x9 - status reg.
40                         Bit 0 - transaction is completed.
41                         Bit 4 - ACK/NACK.
42 DATAx           0xa - 0x54  - 68 bytes data buffer regs.
43                         For write transaction address is specified in four first bytes
44                         (DATA1 - DATA4), data starting from DATA4.
45                         For read transactions address is sent in a separate transaction and
46                         specified in the four first bytes (DATA0 - DATA3). Data is read
47                         starting from DATA0.