2 # PMBus chip drivers configuration
5 menuconfig PMBUS
6         tristate "PMBus support"
7         depends on I2C
8         default n
9         help
10           Say yes here if you want to enable PMBus support.
12           This driver can also be built as a module. If so, the module will
13           be called pmbus_core.
15 if PMBUS
17 config SENSORS_PMBUS
18         tristate "Generic PMBus devices"
19         default y
20         help
21           If you say yes here you get hardware monitoring support for generic
22           PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
23           MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, TPS40400, TPS544B20,
24           TPS544B25, TPS544C20, TPS544C25, and UDT020.
26           This driver can also be built as a module. If so, the module will
27           be called pmbus.
29 config SENSORS_ADM1275
30         tristate "Analog Devices ADM1275 and compatibles"
31         default n
32         help
33           If you say yes here you get hardware monitoring support for Analog
34           Devices ADM1075, ADM1275, ADM1276, ADM1278, ADM1293, and ADM1294
35           Hot-Swap Controller and Digital Power Monitors.
37           This driver can also be built as a module. If so, the module will
38           be called adm1275.
40 config SENSORS_LM25066
41         tristate "National Semiconductor LM25066 and compatibles"
42         default n
43         help
44           If you say yes here you get hardware monitoring support for National
45           Semiconductor LM25056, LM25066, LM5064, and LM5066.
47           This driver can also be built as a module. If so, the module will
48           be called lm25066.
50 config SENSORS_LTC2978
51         tristate "Linear Technologies LTC2978 and compatibles"
52         default n
53         help
54           If you say yes here you get hardware monitoring support for Linear
55           Technology LTC2974, LTC2975, LTC2977, LTC2978, LTC2980, LTC3880,
56           LTC3883, LTC3886, LTC3887, LTCM2987, LTM4675, and LTM4676.
58           This driver can also be built as a module. If so, the module will
59           be called ltc2978.
61 config SENSORS_LTC2978_REGULATOR
62         bool "Regulator support for LTC2978 and compatibles"
63         depends on SENSORS_LTC2978 && REGULATOR
64         help
65           If you say yes here you get regulator support for Linear
66           Technology LTC2974, LTC2977, LTC2978, LTC3880, LTC3883, and LTM4676.
68 config SENSORS_LTC3815
69         tristate "Linear Technologies LTC3815"
70         default n
71         help
72           If you say yes here you get hardware monitoring support for Linear
73           Technology LTC3815.
75           This driver can also be built as a module. If so, the module will
76           be called ltc3815.
78 config SENSORS_MAX16064
79         tristate "Maxim MAX16064"
80         default n
81         help
82           If you say yes here you get hardware monitoring support for Maxim
83           MAX16064.
85           This driver can also be built as a module. If so, the module will
86           be called max16064.
88 config SENSORS_MAX20751
89         tristate "Maxim MAX20751"
90         default n
91         help
92           If you say yes here you get hardware monitoring support for Maxim
93           MAX20751.
95           This driver can also be built as a module. If so, the module will
96           be called max20751.
98 config SENSORS_MAX34440
99         tristate "Maxim MAX34440 and compatibles"
100         default n
101         help
102           If you say yes here you get hardware monitoring support for Maxim
103           MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461.
105           This driver can also be built as a module. If so, the module will
106           be called max34440.
108 config SENSORS_MAX8688
109         tristate "Maxim MAX8688"
110         default n
111         help
112           If you say yes here you get hardware monitoring support for Maxim
113           MAX8688.
115           This driver can also be built as a module. If so, the module will
116           be called max8688.
118 config SENSORS_TPS40422
119         tristate "TI TPS40422"
120         default n
121         help
122           If you say yes here you get hardware monitoring support for TI
123           TPS40422.
125           This driver can also be built as a module. If so, the module will
126           be called tps40422.
128 config SENSORS_UCD9000
129         tristate "TI UCD90120, UCD90124, UCD90160, UCD9090, UCD90910"
130         default n
131         help
132           If you say yes here you get hardware monitoring support for TI
133           UCD90120, UCD90124, UCD90160, UCD9090, UCD90910, Sequencer and System
134           Health Controllers.
136           This driver can also be built as a module. If so, the module will
137           be called ucd9000.
139 config SENSORS_UCD9200
140         tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
141         default n
142         help
143           If you say yes here you get hardware monitoring support for TI
144           UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
145           Digital PWM System Controllers.
147           This driver can also be built as a module. If so, the module will
148           be called ucd9200.
150 config SENSORS_ZL6100
151         tristate "Intersil ZL6100 and compatibles"
152         default n
153         help
154           If you say yes here you get hardware monitoring support for Intersil
155           ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
156           ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
157           Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
159           This driver can also be built as a module. If so, the module will
160           be called zl6100.
162 endif # PMBUS