1 What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
4 Contact: source@cogentembedded.com
6 Program sensor type for threshold detector inputs.
7 Could be either "GND-Open" or "Supply-Open" mode. Y is a
8 threshold detector input channel. Channels 0..7, 8..15, 16..23
9 and 24..31 has common sensor types.
11 What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
14 Contact: source@cogentembedded.com
16 Channel Y low voltage threshold. If sensor input voltage goes lower then
17 this value then the threshold falling event is pushed.
18 Depending on in_voltageY_sensing_mode the low voltage threshold
19 is separately set for "GND-Open" and "Supply-Open" modes.
20 Channels 0..31 have common low threshold values, but could have different
23 The low voltage threshold range is between 2..21V.
24 Hysteresis between low and high thresholds can not be lower then 2 and
27 If falling threshold results hysteresis to odd value then rising
28 threshold is automatically subtracted by one.
30 What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
33 Contact: source@cogentembedded.com
35 Channel Y high voltage threshold. If sensor input voltage goes higher then
36 this value then the threshold rising event is pushed.
37 Depending on in_voltageY_sensing_mode the high voltage threshold
38 is separately set for "GND-Open" and "Supply-Open" modes.
40 Channels 0..31 have common high threshold values, but could have different
43 The high voltage threshold range is between 3..22V.
44 Hysteresis between low and high thresholds can not be lower then 2 and
47 If rising threshold results hysteresis to odd value then falling
48 threshold is automatically appended by one.