1 What: /sys/class/leds/<led>/flash_brightness
4 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
5 Description: read/write
6 Set the brightness of this LED in the flash strobe mode, in
7 microamperes. The file is created only for the flash LED devices
8 that support setting flash brightness.
10 The value is between 0 and
11 /sys/class/leds/<led>/max_flash_brightness.
13 What: /sys/class/leds/<led>/max_flash_brightness
16 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
17 Description: read only
18 Maximum brightness level for this LED in the flash strobe mode,
21 What: /sys/class/leds/<led>/flash_timeout
24 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
25 Description: read/write
26 Hardware timeout for flash, in microseconds. The flash strobe
27 is stopped after this period of time has passed from the start
28 of the strobe. The file is created only for the flash LED
29 devices that support setting flash timeout.
31 What: /sys/class/leds/<led>/max_flash_timeout
34 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
35 Description: read only
36 Maximum flash timeout for this LED, in microseconds.
38 What: /sys/class/leds/<led>/flash_strobe
41 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
42 Description: read/write
43 Flash strobe state. When written with 1 it triggers flash strobe
44 and when written with 0 it turns the flash off.
46 On read 1 means that flash is currently strobing and 0 means
49 What: /sys/class/leds/<led>/flash_fault
52 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
53 Description: read only
54 Space separated list of flash faults that may have occurred.
55 Flash faults are re-read after strobing the flash. Possible
59 flash controller voltage to the flash LED
60 has exceeded the limit specific to the flash controller
61 * flash-timeout-exceeded
62 the flash strobe was still on when
63 the timeout set by the user has expired; not all flash
64 controllers may set this in all such conditions
65 * controller-over-temperature
66 the flash controller has
68 * controller-short-circuit
69 the short circuit protection
70 of the flash controller has been triggered
71 * led-power-supply-over-current
72 current in the LED power
73 supply has exceeded the limit specific to the flash
76 the flash controller has detected
77 a short or open circuit condition on the indicator LED
79 flash controller voltage to the flash
80 LED has been below the minimum limit specific to
82 * controller-under-voltage
83 the input voltage of the flash
84 controller is below the limit under which strobing the
85 flash at full current will not be possible;
86 the condition persists until this flag is no longer set
87 * led-over-temperature
88 the temperature of the LED has exceeded
89 its allowed upper limit