3 Only the Broadcom V3D 3.x and newer GPUs are covered by this binding.
4 For V3D 2.x, see brcm,bcm-vc4.txt.
7 - compatible: Should be "brcm,7268-v3d" or "brcm,7278-v3d"
8 - reg: Physical base addresses and lengths of the register areas
9 - reg-names: Names for the register areas. The "hub" and "core0"
10 register areas are always required. The "gca" register area
11 is required if the GCA cache controller is present. The
12 "bridge" register area is required if an external reset
13 controller is not present.
14 - interrupts: The interrupt numbers. The first interrupt is for the hub,
15 while the following interrupts are separate interrupt lines
16 for the cores (if they don't share the hub's interrupt).
17 See bindings/interrupt-controller/interrupts.txt
20 - clocks: The core clock the unit runs on
21 - resets: The reset line for v3d, if not using a mapping of the bridge
22 See bindings/reset/reset.txt
25 compatible = "brcm,7268-v3d";
26 reg = <0xf1204000 0x100>,
30 reg-names = "bridge", "hub", "core0", "gca";
31 interrupts = <0 78 4>,