1 Bindings for a fan connected to the PWM lines
3 Required properties:
4 - compatible    : "pwm-fan"
5 - pwms          : the PWM that is used to control the PWM fan
6 - cooling-levels      : PWM duty cycle values in a range from 0 to 255
7                         which correspond to thermal cooling states
9 Optional properties:
10 - fan-supply            : phandle to the regulator that provides power to the fan
11 - interrupts            : This contains an interrupt specifier for each fan
12                           tachometer output connected to an interrupt source.
13                           The output signal must generate a defined number of
14                           interrupts per fan revolution, which require that
15                           it must be self resetting edge interrupts. See
16                           interrupt-controller/interrupts.txt for the format.
17 - pulses-per-revolution : define the number of pulses per fan revolution for
18                           each tachometer input as an integer (default is 2
19                           interrupts per revolution). The value must be
20                           greater than zero.
22 Example:
23         fan0: pwm-fan {
24                 compatible = "pwm-fan";
25                 #cooling-cells = <2>;
26                 pwms = <&pwm 0 10000 0>;
27                 cooling-levels = <0 102 170 230>;
28         };
30         thermal-zones {
31                 cpu_thermal: cpu-thermal {
32                              thermal-sensors = <&tmu 0>;
33                              polling-delay-passive = <0>;
34                              polling-delay = <0>;
35                              trips {
36                                         cpu_alert1: cpu-alert1 {
37                                                     temperature = <100000>; /* millicelsius */
38                                                     hysteresis = <2000>; /* millicelsius */
39                                                     type = "passive";
40                                         };
41                              };
42                              cooling-maps {
43                                         map0 {
44                                                     trip = <&cpu_alert1>;
45                                                     cooling-device = <&fan0 0 1>;
46                                         };
47                              };
48                 };
50 Example 2:
51         fan0: pwm-fan {
52                 compatible = "pwm-fan";
53                 pwms = <&pwm 0 40000 0>;
54                 fan-supply = <&reg_fan>;
55                 interrupt-parent = <&gpio5>;
56                 interrupts = <1 IRQ_TYPE_EDGE_FALLING>;
57                 pulses-per-revolution = <2>;
58         };
60 Example 3:
61         fan0: pwm-fan {
62                 compatible = "pwm-fan";
63                 pwms = <&pwm1 0 25000 0>;
64                 interrupts-extended = <&gpio1 1 IRQ_TYPE_EDGE_FALLING>,
65                         <&gpio2 5 IRQ_TYPE_EDGE_FALLING>;
66                 pulses-per-revolution = <2>, <1>;
67         };