WIP FPC-III support
[linux/fpc-iii.git] / Documentation / devicetree / bindings / regulator / ti-abb-regulator.txt
blob6a23ad9ac53a4cabc85a6bc592a873f38c7c144b
1 Adaptive Body Bias(ABB) SoC internal LDO regulator for Texas Instruments SoCs
3 Required Properties:
4 - compatible: Should be one of:
5   - "ti,abb-v1" for older SoCs like OMAP3
6   - "ti,abb-v2" for newer SoCs like OMAP4, OMAP5
7   - "ti,abb-v3" for a generic definition where setup and control registers are
8      provided (example: DRA7)
9 - reg: Address and length of the register set for the device. It contains
10   the information of registers in the same order as described by reg-names
11 - reg-names: Should contain the reg names
12   - "base-address"      - contains base address of ABB module (ti,abb-v1,ti,abb-v2)
13   - "control-address"   - contains control register address of ABB module (ti,abb-v3)
14   - "setup-address"     - contains setup register address of ABB module (ti,abb-v3)
15   - "int-address"       - contains address of interrupt register for ABB module
16   (also see Optional properties)
17 - #address-cells: should be 0
18 - #size-cells: should be 0
19 - clocks: should point to the clock node used by ABB module
20 - ti,settling-time: Settling time in uSecs from SoC documentation for ABB module
21         to settle down(target time for SR2_WTCNT_VALUE).
22 - ti,clock-cycles: SoC specific data about count of system ti,clock-cycles used for
23         computing settling time from SoC Documentation for ABB module(clock
24         cycles for SR2_WTCNT_VALUE).
25 - ti,tranxdone-status-mask: Mask to the int-register to write-to-clear mask
26         indicating LDO tranxdone (operation complete).
27 - ti,abb_info: An array of 6-tuples u32 items providing information about ABB
28         configuration needed per operational voltage of the device.
29         Each item consists of the following in the same order:
30         volt: voltage in uV - Only used to index ABB information.
31         ABB mode: one of the following:
32                 0-bypass
33                 1-Forward Body Bias(FBB)
34                 3-Reverse Body Bias(RBB)
35         efuse:  (see Optional properties)
36         RBB enable efuse Mask:  (See Optional properties)
37         FBB enable efuse Mask:  (See Optional properties)
38         Vset value efuse Mask:  (See Optional properties)
40         NOTE: If more than 1 entry is present, then regulator is setup to change
41               voltage, allowing for various modes to be selected indexed off
42               the regulator. Further, ABB LDOs are considered always-on by
43               default.
45 Optional Properties:
46 - reg-names: In addition to the required properties, the following are optional
47   - "efuse-address"     - Contains efuse base address used to pick up ABB info.
48   - "ldo-address"       - Contains address of ABB LDO override register.
49         "efuse-address" is required for this.
50 - ti,ldovbb-vset-mask   - Required if ldo-address is set, mask for LDO override
51         register to provide override vset value.
52 - ti,ldovbb-override-mask - Required if ldo-address is set, mask for LDO
53         override register to enable override vset value.
54 - ti,abb_opp_sel: Addendum to the description in required properties
55         efuse: Mandatory if 'efuse-address' register is defined. Provides offset
56                from efuse-address to pick up ABB characteristics. Set to 0 if
57                'efuse-address' is not defined.
58         RBB enable efuse Mask:  Optional if 'efuse-address' register is defined.
59                 'ABB mode' is force set to RBB mode if value at "efuse-address"
60                 + efuse maps to RBB mask. Set to 0 to ignore this.
61         FBB enable efuse Mask:  Optional if 'efuse-address' register is defined.
62                 'ABB mode' is force set to FBB mode if value at "efuse-address"
63                 + efuse maps to FBB mask (valid only if RBB mask does not match)
64                 Set to 0 to ignore this.
65         Vset value efuse Mask:  Mandatory if ldo-address is set. Picks up from
66                 efuse the value to set in 'ti,ldovbb-vset-mask' at ldo-address.
68 Example #1: Simplest configuration (no efuse data, hard coded ABB table):
69 abb_x: regulator-abb-x {
70         compatible = "ti,abb-v1";
71         regulator-name = "abb_x";
72         #address-cells = <0>;
73         #size-cells = <0>;
74         reg = <0x483072f0 0x8>, <0x48306818 0x4>;
75         reg-names = "base-address", "int-address";
76         ti,tranxdone-status-mask = <0x4000000>;
77         clocks = <&sysclk>;
78         ti,settling-time = <30>;
79         ti,clock-cycles = <8>;
80         ti,abb_info = <
81         /* uV           ABB     efuse   rbb_m   fbb_m   vset_m */
82         1012500         0       0       0       0       0 /* Bypass */
83         1200000         3       0       0       0       0 /* RBB mandatory */
84         1320000         1       0       0       0       0 /* FBB mandatory */
85         >;
88 Example #2: Efuse bits contain ABB mode setting (no LDO override capability)
89 abb_y: regulator-abb-y {
90         compatible = "ti,abb-v2";
91         regulator-name = "abb_y";
92         #address-cells = <0>;
93         #size-cells = <0>;
94         reg = <0x4a307bd0 0x8>, <0x4a306014 0x4>, <0x4A002268 0x8>;
95         reg-names = "base-address", "int-address", "efuse-address";
96         ti,tranxdone-status-mask = <0x4000000>;
97         clocks = <&sysclk>;
98         ti,settling-time = <50>;
99         ti,clock-cycles = <16>;
100         ti,abb_info = <
101         /* uV           ABB     efuse   rbb_m   fbb_m   vset_m */
102         975000          0       0       0       0       0 /* Bypass */
103         1012500         0       0       0x40000 0       0 /* RBB optional */
104         1200000         0       0x4     0       0x40000 0 /* FBB optional */
105         1320000         1       0       0       0       0 /* FBB mandatory */
106         >;
109 Example #3: Efuse bits contain ABB mode setting and LDO override capability
110 abb_z: regulator-abb-z {
111         compatible = "ti,abb-v2";
112         regulator-name = "abb_z";
113         #address-cells = <0>;
114         #size-cells = <0>;
115         reg = <0x4ae07ce4 0x8>, <0x4ae06010 0x4>,
116               <0x4a002194 0x8>, <0x4ae0C314 0x4>;
117         reg-names = "base-address", "int-address",
118                     "efuse-address", "ldo-address";
119         ti,tranxdone-status-mask = <0x8000000>;
120         /* LDOVBBMM_MUX_CTRL */
121         ti,ldovbb-override-mask = <0x400>;
122         /* LDOVBBMM_VSET_OUT */
123         ti,ldovbb-vset-mask = <0x1F>;
124         clocks = <&sysclk>;
125         ti,settling-time = <50>;
126         ti,clock-cycles = <16>;
127         ti,abb_info = <
128         /* uV   ABB     efuse   rbb_m   fbb_m   vset_m */
129         975000  0       0       0       0       0       /* Bypass */
130         1200000 0       0x4     0       0x40000 0x1f00  /* FBB optional, vset */
131         >;